Your design team should develop formal guidelines for conducting observations. You may wish to consider flowcharting the procedure to ensure that you have a logical sequence of events everyone can understand. Here are some questions your design team should consider  [Pg.82]

The remainder of this section will discuss some design options and considerations for answering each of these questions. After your design team has resolved them, you should draft a written procedure with step-by-step instructions for each of these components. [Pg.83]

While having a dedicated group of observers may seem a good idea and may even be appropriate for some organizations, it often creates an us-versus-them divisiveness that does not promote the sense that safety is everyone s responsibility. In the worst case, other employees consider the observers to be a sort of safety police, and the effect is almost the same as adding an additional layer of supervision within the organization. [Pg.83]

Is being an observer voluntary For most organizations that implement behavioral safety, participation as an observer is voluntary for employees, but this is a decision that should be made by the design team. In some organizations, conducting observations is voluntary for employees but is required of managers, supervisors, and steering committee members. [Pg.83]

Some organizations implement programs in which conducting observations is a job requirement. The problem with this approach is that it can increase the number of forms that are completed as a paperwork exercise without actual observations. [Pg.83]


Abstract. The essential purpose of this study is to develop the measurement procedures in order to evaluate the quality of the observations carried out using Terrestrial Laser Scanner (TLS) equipment. It tries, in addition, to estimate an uncertainty value that allows the users to know the reliability of the instrument measurements. The fundamental idea of this paper is to show the metrological control s need, and the quality of measure s evaluation for TLS equipment and to describe a working methodology, able to be reproducible, without the essential need of having a very complex infrastructure. [Pg.88]

Implementation steps (e.g., Establish a design team comprised of front-line supervisors and representative employees to develop the observation checklist and procedures ). [Pg.48]

The first task in developing an observation procedure is to analyze the incidents and injuries within your organization. Typically you will want to review every incident that has occurred within the last three to five years, then determine the practices that would have prevented the injuries from occurring. During this analysis you have five objectives that wUl be important as you develop your observation process ... [Pg.70]

The activities under interpretation are divided into four categories. Troubleshooting is a procedure to identify and solve a problem in the unit. Hypothesized causes for the observed problems are developed and then tested with appropriate measurements or identification of changes in operating conditions. [Pg.2572]

A rule of thumb has been developed after a large number of analytes were tested. Once the selectivity was observed on the coupled column, a baseline separation can always be achieved on a 25 cm column under optimized conditions. Since the screening procedure already indicates the separation conditions, optimization is straightforward and requires a minimum amount of time. [Pg.44]

Now, starting with 0.05 mL toluene, repeat the procedure to obtain five working solutions l -5 and use solution 5 to plot the absorption curve of toluene again record the Amax values for the peaks of the curve. There is a well-developed peak at approximately 270 nm, and using the five test solutions, measure the absorbance of each at the observed peak wavelength and test the application of Beer s Law. Measure solution 5 also at the wavelength used for benzene, and solution 5 at the wavelength used for toluene. [Pg.715]

Pulse techniques, coupled with the observation of the decay of enhancement (Atkins et al., 1970a, b Glarum and Marshall, 1970 Smaller etal., 1971) constitute the most sensitive procedure for detecting CIDEP. Both net and multiplet polarization have been described. As with CIDNP, the former is believed to arise essentially from the Zeeman interaction and the latter from the hyperfine term. Qualitative rules analogous to Kaptein s rules should be capable of development. [Pg.121]

TLC Analysis. Samples were examined by TLC using standard procedures. Rf values were determined and compared with those of authentic reference materials. Radioactive components were located by scanning (Vanguard Instrument Corp., North Haven, Conn., Model 885) or by autoradiography (Eastman Kodak, Rochester, N. Y., type AA film). The relative Rf value of DCDD on silica gel plates (Brinkmann Instruments, Inc., Westbury, N. Y., type For,4) when developed with n-hexane dioxane acetic acid, 90 10 4, V/V/V, was 0.90. The observed impurity had a relative Rf value of 0.40. On Brinkmann alumina plates, developed with n-hexane, DCDD had a relative Rf of 0.32. Neither system separated the chlorinated dibenzodioxin isomers. [Pg.6]

A number of procedures for stereoselective synthesis of alkenes involving alkenylboranes have been developed. For each of the reactions given below, show the structure of the intermediates and outline the mechanism in sufficient detail to account for the observed stereoselectivity. [Pg.856]


See other pages where Develop the Observation Procedure is mentioned: [Pg.70]    [Pg.82]    [Pg.83]    [Pg.83]    [Pg.85]    [Pg.87]    [Pg.70]    [Pg.82]    [Pg.83]    [Pg.83]    [Pg.85]    [Pg.87]    [Pg.39]    [Pg.79]    [Pg.44]    [Pg.2]    [Pg.92]    [Pg.445]    [Pg.1914]    [Pg.219]    [Pg.209]    [Pg.102]    [Pg.1202]    [Pg.831]    [Pg.245]    [Pg.94]    [Pg.137]    [Pg.334]    [Pg.568]    [Pg.141]    [Pg.103]    [Pg.454]    [Pg.405]    [Pg.128]    [Pg.281]    [Pg.831]    [Pg.36]    [Pg.4]    [Pg.707]    [Pg.517]    [Pg.627]    [Pg.378]    [Pg.132]    [Pg.129]    [Pg.99]    [Pg.74]   