Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Description of the Preferred Method

The HPLC methodology currently employed may be conveniently discussed using as a specific example, the separation of E/Z p-coumaryl 1, 5, coniferyl 2, 6, and sinapyl 3, 7 alcohols (see Fig. 9.2.6). This separation can be achieved using a Waters Novapak column (4 p 3.9 x 150 mm) eluted with MeOH—H20 (15 85 v/v) as described below (Lewis et al. 1989). [Pg.557]


Electron dynamic scattering must be considered for the interpretation of experimental diffraction intensities because of the strong electron interaction with matter for a crystal of more than 10 nm thick. For a perfect crystal with a relatively small unit cell, the Bloch wave method is the preferred way to calculate dynamic electron diffraction intensities and exit-wave functions because of its flexibility and accuracy. The multi-slice method or other similar methods are best in case of diffraction from crystals containing defects. A recent description of the multislice method can be found in [8]. [Pg.153]

In this section, a very brief description of the box method is given. This is the method as originally devised by Feldberg [1]. It is, in the opinion of the present author, awkward and outdated, although many prefer it because it appears... [Pg.54]

Reversed-phase HPLC followed by post-column derivatization and subsequent fluorescence detection is the most common technique for quantitative determination of oxime carbamate insecticides in biological and environmental samples. However, for fast, sensitive, and specific analysis of biological and environmental samples, detection by MS and MS/MS is preferred over fluorescence detection. Thus, descriptions and recommendations for establishing and optimizing HPLC fluorescence, HPLC/ MS, and HPLC/MS/MS analyses are discussed first. This is followed by specific rationales for methods and descriptions of the recommended residue methods that are applicable to most oxime carbamates in plant, animal tissue, soil, and water matrices. [Pg.1147]

Validation protocols are required to describe the objective, methodology, and acceptance criteria for installation, operational, and performance qualifications. They are written to ensure test methods, and acceptance criteria are reviewed and approved before qualification of protocols. In practical terms, there are several stages for the production of protocols. First, an acceptable format needs to be agreed. No universal format exists for protocols, but to some extent, the type of equipment, the size of the project, and the personal preferences will dictate the protocol style. However, some norms have been established. Like other controlled documents, protocols are assigned unique reference numbers and revision numbers. They are titled and numbered on every page and have a particular place for approval signatures. Other common elements in protocols tend to be brief descriptions of the item being qualified and a clear statement of responsibilities. [Pg.816]

Particle size is one of the principal determinants of powder behavior such as packing and consolidation, flow ability, compaction, etc., and it is therefore one of the most common and important areas of powder characterization. Typically, one refers to particle size or diameter as the largest dimension of its individual particles. Because a given powder consists of particles of many sizes, it is preferable to measure and describe the entire distribution. While many methods of size determination exist, no one method is perfect (5) two very common methods are sieve analysis and laser diffraction. Sieving is a very simple and inexpensive method, but it provides data at relatively few points within a distribution and is often very operator dependent. Laser diffraction is a very rapid technique and provides a detailed description of the distribution. However, its instrumentation is relatively expensive, the analytical results are subject to the unique and proprietary algorithms of the equipment manufacturer, and they often assume particle sphericity. The particle size distribution shown in Figure 1 was obtained by laser diffraction, where the curves represent frequency and cumulative distributions. [Pg.129]

Although ASCF methods are more likely to be successful, it is critical that diffuse functions be included in the basis set so that the description of the radical anion is adequate with respect to the loosely held extra electron. In general, correlated methods are to be preferred, and DFT represents a reasonably efficient choice that seems to be robust so long as the radical anion is not subject to overdelocalization problems. Semiempirical methods do rather badly for EAs, at least in part because of their use of minimal basis sets. [Pg.331]

The inversion of this transform gives a somewhat cumbersome integral, of which the physical meaning is far from obvious, and Lighthill Whitham naturally prefer to elucidate this form the asymptotic behaviour of the transform, by the method of steepest descents. The method presented here also uses the transform without the need for inversion and obtains a description of the wave in terms of its moments. [Pg.138]

With small molecules, it is usually possible to obtain anisotropic temperature factors during refinement, giving a picture of the preferred directions of vibration for each atom. But a description of anisotropic vibration requires six parameters per atom, vastly increasing the computational task. In many cases, the total number of parameters sought, including three atomic coordinates, one occupancy, and six thermal parameters per atom, approaches or exceeds the number of measured reflections. As mentioned earlier, for refinement to succeed, observations (measured reflections and constraints such as bond lengths) must outnumber the desired parameters, so that least-squares solutions are adequately overdetermined. For this reason, anisotropic temperature factors for proteins have not usually been obtained. The increased resolution possible with synchrotron sources and cryocrystallography will make their determination more common. With this development, it will become possible to obtain better estimates of uncertainties in atom positions than those provided by the Luzzati method. [Pg.165]

Quantum chemical methods aim to treat the fundamental quantum mechanics of electronic structure, and so can be used to model chemical reactions. Such quantum chemical methods are more flexible and more generally applicable than molecular mechanics methods, and so are often preferable and can be easier to apply. The major problem with electronic structure calculations on enzymes is presented by the very large computational resources required, which significantly limits the size of the system that can be treated. To overcome this problem, small models of enzyme active sites can be studied in isolation (and perhaps with an approximate model of solvation). Alternatively, a quantum chemical treatment of the enzyme active site can be combined with a molecular mechanics description of the protein and solvent environment the QM/MM approach. Both will be described below. [Pg.280]

When the copolymerization is carried out under real conditions, each researcher is to answer a question which kinetic model is preferable for the proper description of the experimental data. One should also know the validity of the model under consideration, the numerical values of its parameters, and the expected accuracy of the calculated copolymer characteristics predicted within the framework of this model. Modern experimental methods for analyzing the copolymer composition... [Pg.54]


See other pages where Description of the Preferred Method is mentioned: [Pg.557]    [Pg.587]    [Pg.4]    [Pg.591]    [Pg.557]    [Pg.587]    [Pg.4]    [Pg.591]    [Pg.533]    [Pg.426]    [Pg.2]    [Pg.17]    [Pg.80]    [Pg.462]    [Pg.390]    [Pg.269]    [Pg.585]    [Pg.295]    [Pg.825]    [Pg.275]    [Pg.216]    [Pg.106]    [Pg.89]    [Pg.163]    [Pg.47]    [Pg.462]    [Pg.269]    [Pg.263]    [Pg.93]    [Pg.110]    [Pg.261]    [Pg.24]    [Pg.133]    [Pg.178]    [Pg.204]    [Pg.33]    [Pg.266]    [Pg.168]    [Pg.585]    [Pg.117]    [Pg.24]    [Pg.90]   


SEARCH



Description of Method

Descriptive method

Method descriptions

Preference methods

© 2024 chempedia.info