Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Dependability advantage

There are clear advantages and also clear disadvantages in this new approach for the analysis of nonisothermal measurements [33], Now there are two new parameters, AS and AH, for each rate constant, i.e., there are twice as many parameters to be fitted. Naturally, this can lead to difficulties if not all of them are well defined. Another problem lies in the fact that molar absorptivity spectra of the species can show significant temperature dependencies. Advantages include the fact that, in... [Pg.254]

Note that in liquid phase chromatography there are no detectors that are both sensitive and universal, that is, which respond linearly to solute concentration regardless of its chemical nature. In fact, the refractometer detects all solutes but it is not very sensitive its response depends evidently on the difference in refractive indices between solvent and solute whereas absorption and UV fluorescence methods respond only to aromatics, an advantage in numerous applications. Unfortunately, their coefficient of response (in ultraviolet, absorptivity is the term used) is highly variable among individual components. [Pg.27]

Royalty is charged from the start of production, but tax is only payable once there is a positive taxable income. At the beginning of a new project the fiscal costs may exceed the revenues, giving rise to a negative taxable income. Whether the project can take advantage of this depends upon the fiscal status of the company and the project. [Pg.309]

The field that generates these eddy currents is, by its nature, anisotropic, i e the eddy current signal response is directionally dependent on probe orientation. This can be used advantageously if one bears in mind that the corroded material one aims to detect usually displays random peaks and valleys, while man-made edges have a definite orientation. [Pg.283]

The specific advantage of this technique is its higher sensitivity than classical film radiography and the potential for automated image processing due to the digital read-out of the IP s. Former investigations have shown / / that the available IP s achieve the same contrast like NDT films with an IP type and scanner dependent unsharpness. [Pg.516]

For the highest resolution and sensitivity, laser-based spectrometers must be used. These have tire advantage that the resolution depends on the linewidth of the laser, rather than the monocln-omator. Furthennore, at any given moment, all of the power is at the frequency of mterest, rather than being spread out over the whole IR... [Pg.1168]

Laser Raman diagnostic teclmiques offer remote, nonintnisive, nonperturbing measurements with high spatial and temporal resolution [158], This is particularly advantageous in the area of combustion chemistry. Physical probes for temperature and concentration measurements can be debatable in many combustion systems, such as furnaces, internal combustors etc., since they may disturb the medium or, even worse, not withstand the hostile enviromnents [159]. Laser Raman techniques are employed since two of the dominant molecules associated with air-fed combustion are O2 and N2. Flomonuclear diatomic molecules unable to have a nuclear coordinate-dependent dipole moment caimot be diagnosed by infrared spectroscopy. Other combustion species include CFl, CO2, FI2O and FI2 [160]. These molecules are probed by Raman spectroscopy to detenuine the temperature profile and species concentration m various combustion processes. [Pg.1215]

Pulsed ENDOR offers several distinct advantages over conventional CW ENDOR spectroscopy. Since there is no MW power during the observation of the ESE, klystron noise is largely eliminated. Furthemiore, there is an additional advantage in that, unlike the case in conventional CW ENDOR spectroscopy, the detection of ENDOR spin echoes does not depend on a critical balance of the RE and MW powers and the various relaxation times. Consequently, the temperature is not such a critical parameter in pulsed ENDOR spectroscopy. Additionally the pulsed teclmique pemiits a study of transient radicals. [Pg.1581]

On metals in particular, the dependence of the radiation absorption by surface species on the orientation of the electrical vector can be fiilly exploited by using one of the several polarization techniques developed over the past few decades [27, 28, 29 and 30], The idea behind all those approaches is to acquire the p-to-s polarized light intensity ratio during each single IR interferometer scan since the adsorbate only absorbs the p-polarized component, that spectral ratio provides absorbance infonnation for the surface species exclusively. Polarization-modulation mediods provide the added advantage of being able to discriminate between the signals due to adsorbates and those from gas or liquid molecules. Thanks to this, RAIRS data on species chemisorbed on metals have been successfidly acquired in situ under catalytic conditions [31], and even in electrochemical cells [32]. [Pg.1782]

The polarization dependence of the photon absorbance in metal surface systems also brings about the so-called surface selection rule, which states that only vibrational modes with dynamic moments having components perpendicular to the surface plane can be detected by RAIRS [22, 23 and 24]. This rule may in some instances limit the usefidness of the reflection tecluiique for adsorbate identification because of the reduction in the number of modes visible in the IR spectra, but more often becomes an advantage thanks to the simplification of the data. Furthenuore, the relative intensities of different vibrational modes can be used to estimate the orientation of the surface moieties. This has been particularly useful in the study of self-... [Pg.1782]

Note that the exact adiabatic functions are used on the right-hand side, which in practical calculations must be evaluated by the full derivative on the left of Eq. (24) rather than the Hellmann-Feynman forces. This forai has the advantage that the R dependence of the coefficients, c, does not have to be considered. Using the relationship Eq. (78) for the off-diagonal matrix elements of the right-hand side then leads directly to... [Pg.292]

A potential advantage of methods based on a series expansion of the free energy is that the convergence of the series is determined by the A dependence of the potential energy function meaning that the efficiency of the approach could be enhanced by a judicious choice of coupling scheme. [Pg.152]

The primal advantage of hierarchical databases is that the relationship between the data at the different levels is easy. The simplicity and efficiency of the data model is a great advantage of the hierarchical DBS. Large data sets (scries of measurements where the data values are dependent on different parameters such as boiling point, temperature, or pressure) could be implemented with an acceptable response time. [Pg.233]

Many problems in force field investigations arise from the calculation of Coulomb interactions with fixed charges, thereby neglecting possible mutual polarization. With that obvious drawback in mind, Ulrich Sternberg developed the COSMOS (Computer Simulation of Molecular Structures) force field [30], which extends a classical molecular mechanics force field by serai-empirical charge calculation based on bond polarization theory [31, 32]. This approach has the advantage that the atomic charges depend on the three-dimensional structure of the molecule. Parts of the functional form of COSMOS were taken from the PIMM force field of Lindner et al., which combines self-consistent field theory for r-orbitals ( nr-SCF) with molecular mechanics [33, 34]. [Pg.351]

It will be useful at the very outset to introduce the student to the apparatus that is commonly employed in the organic laboratory. Whether he will personally handle aU the types of apparatus to be described will, of course, depend (i) upon the duration of the course in practical organic chemistry and (ii) upon the facilities provided by the laboratory. Nevertheless, it is deemed advantageous that the student should, at least, know of their existence. [Pg.46]


See other pages where Dependability advantage is mentioned: [Pg.649]    [Pg.19]    [Pg.30]    [Pg.649]    [Pg.19]    [Pg.30]    [Pg.155]    [Pg.218]    [Pg.59]    [Pg.299]    [Pg.711]    [Pg.752]    [Pg.364]    [Pg.1632]    [Pg.1709]    [Pg.1717]    [Pg.1842]    [Pg.1939]    [Pg.1978]    [Pg.2304]    [Pg.2343]    [Pg.2900]    [Pg.2961]    [Pg.2962]    [Pg.110]    [Pg.239]    [Pg.370]    [Pg.423]    [Pg.100]    [Pg.300]    [Pg.368]    [Pg.628]    [Pg.133]    [Pg.390]    [Pg.513]    [Pg.661]    [Pg.14]    [Pg.289]   
See also in sourсe #XX -- [ Pg.19 , Pg.20 ]




SEARCH



Temperature dependent study, advantages

© 2024 chempedia.info