Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Cycle standard

Environmental Standards for Uranium Fuel Cycle Standards for Normal Operation Annual dose not to exceed ... [Pg.340]

Initially, lEC 61508 was developed as a safety and life cycle standard, which was not industry-specific. Later, there have been three separate divisions, viz. lEC 61511 for process industries, lEC 61513 for nuclear plants, and lEC 62061 for machinery sector. lEC 61511 has clearly put forward some guidelines for hardware to be used in SIS. In this standard, there are clearly two divisions, for example, PEs and non-PEs (in loose sense to distinguish from logic solver, because nowadays sensors and final elements also have programming features) like sensors and final control elements. In this part, sensors and final control elements are considered, while PEs will be discussed separately in next clause. [Pg.500]

Anneal temperature -C F Mean life, cycles Minimum life, cycles Standard deviation, cycles... [Pg.362]

The main justification for diesel fuel desulfurization is related to particulate emissions which are subject to very strict rules. Part of the sulfur is transformed first into SO3, then into hydrated sulfuric acid on the filter designed to collect the particulates. Figure 5.21 gives an estimate of the variation of the particulate weights as a function of sulfur content of diesel fuel for heavy vehicles. The effect is greater when the test cycle contains more high temperature operating phases which favor the transformation of SO2 to SO3. This is particularly noticeable in the standard cycle used in Europe (ECE R49). [Pg.254]

Tables 5.29 and 5.30 show an example of the effects of hydrotreated diesel fuels on a diesel passenger car already having a low level of pollution owing to technical modifications such as sophisticated injection and optimized combustion. In the standard European driving cycle (ECE + EUDC), between... Tables 5.29 and 5.30 show an example of the effects of hydrotreated diesel fuels on a diesel passenger car already having a low level of pollution owing to technical modifications such as sophisticated injection and optimized combustion. In the standard European driving cycle (ECE + EUDC), between...
Calculations using the semiempirical PM3 method with standard convergence criteria of 0.0003 aii on the maximum component of the gradient vector and either an energy change from the previous cycle of < 10 hartree or a maximum predicted displacement for the next step of < 0.0003 au. [Pg.2345]

Since the net free energy change for the cycle is zero, the difference between the computable free energies for transforming L to if, when bound to protein and when dissolved in water, is equal to the difference between the measurable standard free energies of binding L and if to protein, i.e., the difference in affinity... [Pg.136]

The two levels of NAAQS, primary and secondary, are Hsted in Table 3. Primary standards were set to protect pubHc health within an adequate margin of safety secondary standards, where appHcable, were chosen to protect pubHc welfare, including vegetation. According to the CAA, the scientific bases for the NAAQS are to be reviewed every 5 years so that the NAAQS levels reflect current knowledge. In practice, however, the review cycle takes considerably longer. [Pg.368]

Modification of BPA-PC for adaptation to the conditions of production of CD and CD-ROM disks, and of substrate disks for WORM and EOD was necessary. BPA-PC standard quaHties for extmsion and injection mol ding have, depending on molecular weight, melt flow indexes (MEI), (according to ISO 1130/ASTM 1238 in g/10 min at 300°C/1.2 kg, between less than 3 g/10 min (viscous types) up to 17 g/10 min. For CDs and optical data storage disks, however, MEI values exceeding 30 g/10 min, and for exceptionally short cycle times (5—7 s) even >60 g/lOmin are demanded at an injection mass temperature of 300°C (see Table 5). [Pg.157]

Quantitative mass spectrometry, also used for pharmaceutical appHcations, involves the use of isotopicaHy labeled internal standards for method calibration and the calculation of percent recoveries (9). Maximum sensitivity is obtained when the mass spectrometer is set to monitor only a few ions, which are characteristic of the target compounds to be quantified, a procedure known as the selected ion monitoring mode (sim). When chlorinated species are to be detected, then two ions from the isotopic envelope can be monitored, and confirmation of the target compound can be based not only on the gc retention time and the mass, but on the ratio of the two ion abundances being close to the theoretically expected value. The spectrometer cycles through the ions in the shortest possible time. This avoids compromising the chromatographic resolution of the gc, because even after extraction the sample contains many compounds in addition to the analyte. To increase sensitivity, some methods use sample concentration techniques. [Pg.548]

The characteristics of interior paints that require testing and analysis include hiding and appearance, package stabiHty, adhesion, spatter resistance, flow and leveling, color and sheen uniformity, touch-up, stain removal, burnish resistance, and block and print resistance. A popular test that assesses the wet abrasion resistance of an interior paint is to measure its scmb resistance. A mechanical device is used to scmb a paint film of a specified thickness with a standard bmsh and abrasive cleanser suspension. The number of scmb cycles (back and forth movements of the weighted bmsh) at various end points (first cut through, or 50% removal of the film) is then recorded. Scmb resistance usually holds steady or decreases slightly as PVC is increased, but drops quickly once the CPVC is exceeded in a paint formulation. [Pg.546]

A 165-MW-class gas turbine/generator has been introduced by another manufacturer. This machine, also developed by scaling up a proven design, features a simple-cycle efficiency of 37.5% a turbine inlet temperature of 1235°C a pressure ratio of 30 1, up from 16 1 on the previous generation and an output of 165 MW for gas fuel firing under International Standards Organization (ISO) conditions (101 kPa, 15°C (14.7 psia, 59°F)). A combined-cycle facihty based around this machine could achieve efficiencies up to 58% or a heat rate of about 6209 kj/kWh (5885 Btu/kWh). [Pg.16]


See other pages where Cycle standard is mentioned: [Pg.81]    [Pg.481]    [Pg.178]    [Pg.136]    [Pg.482]    [Pg.114]    [Pg.537]    [Pg.725]    [Pg.114]    [Pg.795]    [Pg.474]    [Pg.567]    [Pg.81]    [Pg.481]    [Pg.178]    [Pg.136]    [Pg.482]    [Pg.114]    [Pg.537]    [Pg.725]    [Pg.114]    [Pg.795]    [Pg.474]    [Pg.567]    [Pg.2110]    [Pg.2227]    [Pg.2341]    [Pg.2964]    [Pg.521]    [Pg.91]    [Pg.141]    [Pg.360]    [Pg.428]    [Pg.34]    [Pg.488]    [Pg.547]    [Pg.194]    [Pg.380]    [Pg.437]    [Pg.151]    [Pg.237]    [Pg.404]    [Pg.414]    [Pg.236]    [Pg.97]    [Pg.144]    [Pg.145]    [Pg.46]    [Pg.255]   
See also in sourсe #XX -- [ Pg.41 ]




SEARCH



Air standard cycles

Air-standard cooled cycles

Life Cycle Assessment Standards

Standard state cycles

Standards drug life cycle

Thermochemical cycles standard enthalpies of atomization

© 2024 chempedia.info