Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Cross-polarization, solid sample

In addition to sample rotation, a particular solid state NMR experiment is further characterized by the pulse sequence used. As in solution NMR, a multitude of such sequences exist for solids many exploit through-space dipolar couplings for either signal enhancement, spectral assignment, interauclear distance determination or full correlation of the spectra of different nuclei. The most commonly applied solid state NMR experiments are concerned with the measurement of spectra in which intensities relate to the numbers of spins in different environments and the resonance frequencies are dominated by isotropic chemical shifts, much like NMR spectra of solutions. Even so, there is considerable room for useful elaboration the observed signal may be obtained by direct excitation, cross polarization from other nuclei or other means, and irradiation may be applied during observation or in echo periods prior to... [Pg.573]

In the solid state experiments the protons are used to cross-polarize the carbon nuclei. Sufficient time must be allowed for the protons to thermalize with the lattice in between experiments but, unless the sample is inhomogeneous, all protons will share a... [Pg.72]

SPE methods with different cartridge packings have been employed for the pre-concentration and clean up of sulfonated azo dyes from waters and soil extracts [110,111], The extraction of solid samples has been carried ont by sonication or Soxhlet extraction and the extracts treated like the water samples. C18 cartridges and columns [111] were used followed by the elution with aqueous organic solvents in the presence of TEA with recovery yields always greater than 65% [93,111], Higher recoveries have been obtained by using C18 columns, pre-conditioned with an ammonium acetate buffer and elnted with methanol [111], The use of styrene-divinylbenzene [93,112], as well as of cross-linked polymeric sorbents with sulfonate functions, was shown to be suitable in the SPE of the more polar componnds [111],... [Pg.544]

Solid-state C variable-amplitude cross polarization magic-angle spinning (VACP/MAS) nuclear magnetic resonance (NMR) spectra were acquired for the sorbitol samples. Proton decoupling was achieved by a two-pulse phase modulation (TPPM) sequence. Identical C spectra were measured for the y-form sorbitol samples, and a representative spectrum is shown in Figure 9. [Pg.488]

Because amorphous and crystalline solid-state forms contain nonequivalent spatial relationships at the molecular level, they often display differences in functional group vibrational modes that can be measured by IR spectroscopy. Total attenuated reflectance IR spectroscopy is utilized because it is non-destructive and can be used to directly measure actual tablet and capsule samples. Similarly, solid-state NMR spectroscopy is another non-destructive direct analytical method that can detect and measure differences in nuclear resonance frequencies and relaxations, such as those displayed by amorphous and crystalline material. Cross-polarization... [Pg.443]

Both of these methods have been used for DOM isolation from major rivers and the surface ocean, and the general characteristics of these fractions of DOM are presented in Table I. The major C functional groups of humic substances and ultrafiltered DOM (UDOM) have been characterized by solid-state, cross-polarization magic angle spinning 13C nuclear magnetic resonance (NMR) spectroscopy. The samples of humic substances that were characterized by NMR spectroscopy were collected from the Amazon River... [Pg.125]

The solid state high resolution n.m.r. spectra were run on a CXP 200 BruKer spectrometer in which the 31P nucleus resonates at 81 MHz. Samples used were finely powedered and hand-tamped in glass tubes. The spectra were recorded using the Proton Enhanced Nuclear Induction Technique (6) on the same basis of a one shot cross polarization and high power decoupling during acquisition. A capillary tube of trimethylphosphate inserted in the powder sample is used as internal reference. [Pg.581]


See other pages where Cross-polarization, solid sample is mentioned: [Pg.2111]    [Pg.124]    [Pg.418]    [Pg.418]    [Pg.774]    [Pg.95]    [Pg.237]    [Pg.82]    [Pg.107]    [Pg.114]    [Pg.27]    [Pg.85]    [Pg.303]    [Pg.259]    [Pg.64]    [Pg.72]    [Pg.143]    [Pg.119]    [Pg.41]    [Pg.111]    [Pg.119]    [Pg.82]    [Pg.63]    [Pg.429]    [Pg.74]    [Pg.237]    [Pg.876]    [Pg.407]    [Pg.149]    [Pg.101]    [Pg.553]    [Pg.68]    [Pg.124]    [Pg.192]    [Pg.1099]    [Pg.384]    [Pg.385]    [Pg.44]    [Pg.45]    [Pg.592]    [Pg.609]    [Pg.86]   


SEARCH



Crossed polarizers

Crossed polars

Polar solids

Polarizer crossed

Sample polar

Sample solid samples

Sample, polarization

Sampling solids

Solids cross-polarization

© 2024 chempedia.info