Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Control-response sensor

Other thermal zones which should be thermostated separately from the column oven include the Injector and detector ovens. These are generally insulted metal blocks heated by cartridge heaters controlled by sensors located in a feedback loop with the power supply. Detector blocks are usually maintained at a temperature selected to minimize detector contamination from condensation of column bleed or sample components and to optimize the response of the detector to the sample. The requirements for i injectors may be different depending on the injector design and may include provision for temperature program operation. [Pg.123]

The control unit of the reactor should be a quick-response sensor inside the reactor (preferably PtlOO with a three-wire connection) and a proportional controller to achieve optimal temperature constancy. In no case should there be a deviation of more than 0.2°C during operation (during initial warming a little more has to be accepted). [Pg.283]

L. Francioso, D.S. Presicce, M. Epifani, P. Siciliano, A. FicareUa, Response evaluation of Ti02 sensor to flue gas on spark ignition engine and in controlled environment . Sensors and Actuators B, 107, 563-571, (2005). [Pg.151]

Stage 1 At this stage, the electrical instrumentation of the miniplant consists of compact, self-contained individual components, for example, balances, metering controls, metering pumps, thermostats, temperature controllers, pH sensors, individual controllers, control valves, pressure sensors, and plotters. Monitoring and operation is the responsibility of the shift personnel. [Pg.301]

Several methods are used to determine sensor response (S) in the literature, particularly in regard to conductimetric gas sensing, where the ratio of the test response to a control response is determined. The method used typically depends on whether the test response results in a signal that is either greater or lesser than some control value. To avoid confusion and allow standardization, five measures of S are used in this table, denoted Si-Ss- In some publications, these values are further multiplied by 100 to yield a percentage response. However, in this work, all percentage values have been divided by 100 to yield the response quotient. [Pg.593]

Figure 5 Transient response of PEMC sensor to the binding of333 BA spores/mL from a solution containing various amounts of other Bacillus species. The control response shown is that of the anti-BA functionalized PAP EMC exposed to a mixture of BT and BC spores, at concentrations of 166 BT spores/mL and 166 BC spores/mL, so as to establish the baseline frequency change of the sensor. Data presented is from reference (25). Figure 5 Transient response of PEMC sensor to the binding of333 BA spores/mL from a solution containing various amounts of other Bacillus species. The control response shown is that of the anti-BA functionalized PAP EMC exposed to a mixture of BT and BC spores, at concentrations of 166 BT spores/mL and 166 BC spores/mL, so as to establish the baseline frequency change of the sensor. Data presented is from reference (25).
On the other hand, the geometry of individual single-crystal NWs promotes a detailed analysis of-the gas-surface interactions, because there are no necks and boundaries. The decrease in the number of parameters which control the sensor response of ID structures should facilitate a better understanding of the nature of the observed effects. In addition, ID metal oxide nanomaterials have excellent crystallinity and clear faceting with a fixed set of planes. It is expected that these nanomaterials will have less concentration of point defects and specific adsorption and catalytic properties, conditioned by a particular combination of crystallographic planes. In other words, semiconducting ID metal... [Pg.58]

Fig. 2.2 Processes controlling response of high-temperature and low-temperature MOX-based gas sensors... Fig. 2.2 Processes controlling response of high-temperature and low-temperature MOX-based gas sensors...
With the radical reversal of the maximum current trend at 45% GOx, it is enticing to ask whether the same processes control the sensor response after the maximum, as do before it. It is possible to argue that under limiting glucose conditions (Figure 8) and at low enzyme loadings (<40%), the system is kinetically limited by the enzyme-sUbstrate-cosubstrate reaction (reactions i and ii. Scheme I). There are several pieces of evidence that tend to support this assumption. Previously... [Pg.67]

Fig. 10.20. The atomic force microscope. X,Y,Z axe the piezoelectric sensors to control the motion of the probe over the sample in XYZ directions. Force sensor is to measure the force between the probe and the sample. (CPU) Computer - The computer is used for setting the scanning parameters such as scan size, scan speed, feedback control response, and visualizing images captured with the microscope... Fig. 10.20. The atomic force microscope. X,Y,Z axe the piezoelectric sensors to control the motion of the probe over the sample in XYZ directions. Force sensor is to measure the force between the probe and the sample. (CPU) Computer - The computer is used for setting the scanning parameters such as scan size, scan speed, feedback control response, and visualizing images captured with the microscope...
Yao Q, Alici G, Spinks GA (2008) Feedback control of tri-layer polymer actuators to improve their positioning ability and speed of response. Sensors Actuators Phys 144 176-184. doi 10.1016/j. sna.2008.01.005... [Pg.256]

The non-invasive requirement for the hot leg temperature sensor must therefore be evaluated against impacts on reactor control response time. Other factors affecting sensor placement include sensor accuracy and resolution, temperature tolerance, sensor size, and feasible attachment methodologies. The sensor technologies under consideration for measuring the hot gas temperature were ultrasonics, thermocouples, resistance temperature deviees (RTDs), optical pyrometry, and fiber Bragg grating. [Pg.203]

Again, the non-invasive requirement for the hot leg temperature sensor would have been balanced with the reactor control response time requirement in order to maximize sensor performance while minimizing the invasiveness of the sensor placement technique. [Pg.432]


See other pages where Control-response sensor is mentioned: [Pg.174]    [Pg.174]    [Pg.528]    [Pg.186]    [Pg.188]    [Pg.29]    [Pg.116]    [Pg.131]    [Pg.279]    [Pg.172]    [Pg.467]    [Pg.378]    [Pg.219]    [Pg.1266]    [Pg.193]    [Pg.195]    [Pg.480]    [Pg.295]    [Pg.181]    [Pg.254]    [Pg.202]    [Pg.354]    [Pg.277]    [Pg.334]    [Pg.6]    [Pg.273]    [Pg.1646]    [Pg.166]    [Pg.1361]    [Pg.218]    [Pg.394]    [Pg.1331]    [Pg.5]    [Pg.428]    [Pg.434]   
See also in sourсe #XX -- [ Pg.174 ]




SEARCH



Control response

Controlled response

Factors controlling sensor response

Response controller

Sensor response

© 2024 chempedia.info