Contamination checks

Contamination of the production vessel leads to serious financial penalties and each step in the inoculum train is monitored for contamination. To reduce the risk of contamination during sampling it is usual to take a sample from the residue left in each vessel after its contents have been transferred to the next reactor. Since these contamination checks are retrospective, a heavy reliance is placed on the growth characteristics of the production organism. Kinetic variables such as growth rate and oxygen consumption rate are also used to assess the quality of the inoculum. [Pg.206]

If media-fill environmental contaminant is same as sterility test contaminant and if routine environmental contaminant is same as sterility test contaminant check environmental monitoring methods and techniques closely for problems. Review personnel practices, gowning, sanitation, and sterilization. [Pg.886]

Assemble the rotary evaporator according to manufacturer s instructions, and warm the water bath to 45°C. On a daily basis, preclean the rotary evaporator by concentrating 100 mL of clean extraction solvent through the system. Archive both the concentrated solvent and the solvent in the catch flask for contamination check if necessary. Between sample, three 2-3 mL aliquots of toluene should be rinsed down the feed tube into a waste beaker. ... [Pg.468]

Blocked injection gate Check rubber for contamination Check rubber at nozzle for nibs... [Pg.52]

Speed reducer Noise, rapid vibration, oil leaks Check oil level check oil for water or other contamination check breather pipe for clogging check shaft for misalignment. Run idle units for 10 min. [Pg.109]

Swipe tests source swiping, contamination checks. [Pg.250]

Risks of radiation exposure and contamination during the shutdown period are limited. The loading and unloading of the core are potentially the activities involving more risks for the operators. Health physicists are carrying out radiation and contamination checks of the facility in a monthly basis. Radioprotection channels on I C continuously monitor the reactor hall and the exhaust air from the building. [Pg.25]

As a check for the presence of spin contamination, most ah initio programs will print out the expectation value of the total spin <(A >. If there is no spin contamination, this should equal. v(.v + 1), where s equals times the number of unpaired electrons. One rule of thumb, which was derived from experience with... [Pg.227]

Unrestricted calculations often incorporate a spin annihilation step, which removes a large percentage of the spin contamination from the wave function. This helps minimize spin contamination but does not completely prevent it. The final value of (,S y is always the best check on the amount of spin contamination present. In the Gaussian program, the option iop(5/14=2) tells the program to use the annihilated wave function to produce the population analysis. [Pg.228]

Specification tests are performed on plant streams once or twice per worker shift, or even more often if necessary, to assure the continuing quahty of the product. The tests are also performed on a sample from an outgoing shipment, and a sample of the shipment is usually retained for checking on possible subsequent contamination. Tests on specialty types of acetone may require sophisticated instmments, eg, mass spectrometry for isotopicaHy labeled acetone. [Pg.98]

Water. Water mains should be connected to plant fire mains at two or more poiats, so that a sufficient water supply can be deHvered ia case of emergency. The plant loop and its branches should be adequately valved so that a break can be isolated without affecting a principal part of the system. If there is any question of maintaining adequate pressure, suitable booster pumps should be iastaHed. Any connection made to potable water for process water or cooling water must be made ia such a manner that there can be no backflow of possibly contaminated water check valves alone are not sufficient. The municipal supply should faH freely iato a tank from which the water is pumped for process purposes, or commercially available and approved backflow preventers should be used. [Pg.98]

Receipts of tank-car qiiantities or larger are usually checked for gravity, appearance, and flash point to confirm product identification and absence of contamination. [Pg.2365]

The aim of this work is the development of pyrene determination in gasoline and contaminated soils. For this purpose we used room temperature phosphorescence (RTP) in micellar solutions of sodium dodecylsulphate (SDS). For pyrene extraction from contaminated soils hexane was used. Then exttacts earned in glass and dried. After that remains was dissolved in SDS solution in the presence of sodium sulphite as deoxygenation agent and thallium (I) nitrate as heavy atom . For pyrene RTP excitation 337 nm wavelength was used. To check the accuracy of the procedures proposed for pyrene determining by RTP, the pyrene concentrations in the same gasoline samples were also measured by GC-MS. [Pg.116]

Loose drive belts Preventative maintenance checks, tightness and generating fric- protection from contaminants tional heat/static. check belt tension electricity. CCPS G-29... [Pg.68]

Methyl trichlorosilane [75-79-6] M 149.5, b 13,7 /101mm, 64.3 /710.8mm, 65.5 /745mm, 66.1 /atm, d 1.263, n 1.4110. If very pure distil before use. Purity checked by Si nmr, 6 in MeCN is 13.14 with respect to Me4Si. Possible contaminants are other silanes which can be removed by fractional distillation through a Stedman column of >72 theoretical plates with total reflux and 0.35% take-off (see p. 441). The apparatus is under N2 at a rate of 12 bubbles/min fed into the line using an Hg manometer to control the pressure. Sensitive to H2O. [J Am Chem Soc 73 4252 7957 J Org Chem 48 3667 7955.]... [Pg.442]

Control fluid quality during use, involving checks on correct dilution and make-up, concentration and freedom from contamination in service, regular cleaning and fluid changing Provide and use appropriate personal protective equipment A high standard of personal hygiene... [Pg.137]

Check exposures routinely by personal dosimetry or following accidents (in the UK dosimetry services must be approved) and keep records (e.g. in UK for at least 50 years). Notify the relevant employees and authorities as appropriate. Monitor background contamination periodically using equipment that has been checked by qualified persons and keep records of levels (e.g. for 2 years). [Pg.394]

Checking for land contamination, e.g. analysis of soil samples. Record keeping. [Pg.535]

Check the outdoor air intakes to see whether they are located near contaminant sources (e.g., plumbing vents, exhaust outlets, dumpsters, loading docks, or other locations where vehicles idle). See if the space containing the HVAC system is clean and dry. Examples of problems include cleaning or other maintenance supplies... [Pg.205]

The recommendation is to start with Method A, if possible. If this is not possible Method C can be used, but it is recommended that the equations given in Method A, together with approximations of the contaminant s properties, be used to check and/or verify the manufacturer s data. Method B could be used if no other alternative exists. If the design is for a noncommercial or nonstandard exhaust, it is not possible to use Method C and it is strongly recommended to use Method A, even if only approximate values are available. [Pg.847]


See other pages where Contamination checks is mentioned: [Pg.539]    [Pg.220]    [Pg.246]    [Pg.214]    [Pg.34]    [Pg.926]    [Pg.2333]    [Pg.401]    [Pg.73]    [Pg.197]    [Pg.539]    [Pg.220]    [Pg.246]    [Pg.214]    [Pg.34]    [Pg.926]    [Pg.2333]    [Pg.401]    [Pg.73]    [Pg.197]    [Pg.91]    [Pg.460]    [Pg.472]    [Pg.107]    [Pg.16]    [Pg.225]    [Pg.363]    [Pg.386]    [Pg.1]    [Pg.129]    [Pg.397]    [Pg.480]    [Pg.503]    [Pg.551]    [Pg.77]    [Pg.317]    [Pg.220]   
See also in sourсe #XX -- [ Pg.206 ]