Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Contact, stationary

Figure 3.10. The ideal Stern-Volmer constants Ko (solid lines) as functions of diffusion in the contact approximation (a) and for the exponential transfer rate with different tunnelling lengths / = 1.6A (b) and / = 2.5 A (c) (From Ref. 46.) The contact stationary constant k (dashed line) is shown for comparison with contact Kq (a). Figure 3.10. The ideal Stern-Volmer constants Ko (solid lines) as functions of diffusion in the contact approximation (a) and for the exponential transfer rate with different tunnelling lengths / = 1.6A (b) and / = 2.5 A (c) (From Ref. 46.) The contact stationary constant k (dashed line) is shown for comparison with contact Kq (a).
The probes are assumed to be of contact type but are otherwise quite arbitrary. To model the probe the traction beneath it is prescribed and the resulting boundary value problem is first solved exactly by way of a double Fourier transform. To get managable expressions a far field approximation is then performed using the stationary phase method. As to not be too restrictive the probe is if necessary divided into elements which are each treated separately. Keeping the elements small enough the far field restriction becomes very week so that it is in fact enough if the separation between the probe and defect is one or two wavelengths. As each element can be controlled separately it is possible to have phased arrays and also point or line focussed probes. [Pg.157]

In a typical friction measurement, a slider is pressed against a stationary block, and the force required to move it is measured. This force generally comprises two terms the first is the force F required to shear the junctions at the points of actual contact given by... [Pg.434]

Analytical separations may be classified in three ways by the physical state of the mobile phase and stationary phase by the method of contact between the mobile phase and stationary phase or by the chemical or physical mechanism responsible for separating the sample s constituents. The mobile phase is usually a liquid or a gas, and the stationary phase, when present, is a solid or a liquid film coated on a solid surface. Chromatographic techniques are often named by listing the type of mobile phase, followed by the type of stationary phase. Thus, in gas-liquid chromatography the mobile phase is a gas and the stationary phase is a liquid. If only one phase is indicated, as in gas chromatography, it is assumed to be the mobile phase. [Pg.546]

The most widely used particulate support is diatomaceous earth, which is composed of the silica skeletons of diatoms. These particles are quite porous, with surface areas of 0.5-7.5 m /g, which provides ample contact between the mobile phase and stationary phase. When hydrolyzed, the surface of a diatomaceous earth contains silanol groups (-SiOH), providing active sites that absorb solute molecules in gas-solid chromatography. [Pg.564]

Submitting the main topic, we deal with models of solids with cracks. These models of mechanics and geophysics describe the stationary and quasi-stationary deformation of elastic and inelastic solid bodies having cracks and cuts. The corresponding mathematical models are reduced to boundary value problems for domains with singular boundaries. We shall use, if it is possible, a variational formulation of the problems to apply methods of convex analysis. It is of importance to note the significance of restrictions stated a priori at the crack surfaces. We assume that nonpenetration conditions of inequality type at the crack surfaces are fulfilled, which improves the accuracy of these models for contact problems. We also include the modelling of problems with friction between the crack surfaces. [Pg.1]

Most adsorption systems use stationary-bed adsorbers. However, efforts have been made over the years to develop moving-bed adsorption processes in which the adsorbent is moved from an adsorption chamber to another chamber for regeneration, with countercurrent contacting of gases with the adsorbents in each chamber. Union Oil s Hypersorption Process (90) is an example. However, this process proved uneconomical, primarily because of excessive losses resulting from adsorbent attrition. [Pg.285]

The patented system (15) has stationary disks mounted inside a pressure vessel (horizontal vessel, vertical disks) which is mounted on rollers and can rotate slowly about its axis. A screw conveyor is mounted in the stationary center of rotation it conveys the cake, which is blown off the leaves when they pass above the screw, to one end of the vessel where it falls into a vertical chute. The cake discharge system involves two linear sHde valves that sHde the cake through compartments which gradually depressurize it and move it out of the vessel without any significant loss of pressure. The system rehes entirely on the cake falling freely from one compartment to another as the valves move across. This may be an unrealistic assumption, particularly with sticky cakes when combined with lots of sliding contact surfaces which are prone to abrasion and jamming, the practicality of the system is questionable. [Pg.406]

Containerized ice cream is hardened on a stationary or continuous refrigerated plate-contact hardener or by convection air blast as the product is carried on a conveyor or through a tunnel. Air temperatures for hardening are —40 to —50° C. The temperature at the center of the container as well as the storage temperature should be <—26°C. Approximately one-half of the heat is removed at the freezer and the remainder in the hardening process. [Pg.370]

Removal of Free Fatf Fields. Alkali treatment of the oil is accompHshed by the use of caustic soda solutions to neutralize the excess free fatty acids. Because castor oil readily forms emulsions with water and/or alkaline solutions, special techniques have been developed to neutralize the acids. A continuous counter-current process was developed using a stationary contact reactor (15). Treatment in the presence of a solvent is also utilized (16). [Pg.152]

Affinity Chromatography. This technique involves the use of a bioselective stationary phase placed in contact with the material to be purified, the ligate. Because of its rather selective interaction, sometimes called a lock-and-key mechanism, this method is more selective than other lc systems based on differential solubiHty. Affinity chromatography is sometimes called bioselective adsorption. [Pg.110]

Dry-friction whiri. This type of whip is experienced when the surface of a rotating shaft comes into contact with an unlubricated stationary guide. The effect takes place because of an unlubricated journal, contact in radial clearance of labyrinth seals, and loss of clearance in hydrodynamic bearings. [Pg.207]

Because of the minimal contact between the stationary ring and the rotor, these seals, when properly designed, are ideal for high-speed rotating machinery. [Pg.499]

When the silica surface is in contact with a solvent, the surface is covered with a layer of the solvent molecules. If the mobile phase consists of a mixture of solvents, the solvents compete for the surface and it is partly covered by one solvent and partly by the other. Thus, any solute interacting with the stationary phase may well be presented with two, quite different types of surface with which to interact. The probability that a solute molecule will interact with one particular type of surface will be statistically controlled by the proportion of the total surface area that is covered by that particular solvent. [Pg.94]

In a packed column, however, the situation is quite different and more complicated. Only point contact is made between particles and, consequently, the film of stationary phase is largely discontinuous. It follows that, as solute transfer between particles can only take place at the points of contact, diffusion will be severely impeded. In practice the throttling effect of the limited contact area between particles renders the dispersion due to diffusion in the stationary phase insignificant. This is true even in packed LC columns where the solute diffusivity in both phases are of the same order of magnitude. The negligible effect of dispersion due to diffusion in the stationary phase is also supported by experimental evidence which will be included later in the chapter. [Pg.250]


See other pages where Contact, stationary is mentioned: [Pg.502]    [Pg.420]    [Pg.537]    [Pg.502]    [Pg.420]    [Pg.537]    [Pg.57]    [Pg.546]    [Pg.547]    [Pg.547]    [Pg.443]    [Pg.77]    [Pg.573]    [Pg.505]    [Pg.128]    [Pg.260]    [Pg.404]    [Pg.119]    [Pg.380]    [Pg.31]    [Pg.104]    [Pg.105]    [Pg.304]    [Pg.244]    [Pg.250]    [Pg.23]    [Pg.778]    [Pg.1215]    [Pg.1443]    [Pg.162]    [Pg.166]    [Pg.419]    [Pg.502]    [Pg.506]    [Pg.465]    [Pg.156]    [Pg.371]    [Pg.428]   
See also in sourсe #XX -- [ Pg.24 , Pg.78 , Pg.81 , Pg.83 , Pg.84 ]




SEARCH



Stationary phases contact angle

© 2024 chempedia.info