Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Connective detection

How many interactions share two sets of the same organism It has been shown for the first two Y2H experiments performed on the yeast proteome that the interactions common to both sets were estimated at 15-20% (Ito et al. 2001). A comparison between the data sets coming from TAP-TAG (6285 connections detected Gavin et al. 2002) and HMS-PCI (9005 connections detected) has revealed a similar trend between the two data sets 1728 interactions are common to both sets which means that 19.2% of HMS-PCI match with 27.5% of TAP-TAG (von Mering et al. 2002). The same study estimated the level of data accuracy if all interactions are counted with respect to a reference set of known complexes showing a 12.5% accuracy for the TAP-TAG methodology, 2% for HMS-PCI and 3.7% for the two Y2H assays (Ito and Uetz data set). [Pg.150]

Traditionally, homonuclear 2D double quantum filtered correlation spectroscopy (DQF-COSY) and total correlated spectroscopy (TOCSY) spectra are valuable in the identification of resonances of individual monosaccharide units. In the presence of small couplings, through space connectivities detected by NOESY/ROESY (nuclear Overhauser effect spectroscopy/ rotational nuclear Overhauser effect spectroscopy) experiments are also useful in completing the resonance assignment. When the H NMR spectra of complex oligosaccharides are too crowded to fully elucidate the structure by homonuclear correlation methods, it is efficient to use 2D heteronuclear correlation methods, such as heteronuclear single quantum correlation... [Pg.198]

Hambly, A., Henderson, R.K., Storey, M.V., Baker, A., Stuetz, R.M., and Khan, S.J. (2010). Fluorescence monitoring at a recycled water treatment plant and associated dual distribution system - Implications for cross-connection detection. Water Res., 44, 5323-5333. [Pg.116]

In contrast to a direct injection of dc or ac currents in the sample to be tested, the induction of eddy currents by an external excitation coil generates a locally limited current distribution. Since no electrical connection to the sample is required, eddy current NDE is easier to use from a practical point of view, however, the choice of the optimum measurement parameters, like e.g. the excitation frequency, is more critical. Furthermore, the calculation of the current flow in the sample from the measured field distribution tends to be more difficult than in case of a direct current injection. A homogenous field distribution produced by e.g. direct current injection or a sheet inducer [1] allows one to estimate more easily the defect geometry. However, for the detection of technically relevant cracks, these methods do not seem to be easily applicable and sensitive enough, especially in the case of deep lying and small cracks. [Pg.255]

High selective performance of the sensor also enable to detect surface cracks in ferromagnetic and non-magnetic welded connections under rust or dirt layer without prior cleaning. [Pg.288]

The NDT and TD methods and means that solve the proplems connected with the necessaty to find the arms, explosives, radioactive and nuclide sources as well as to detect false documents and securities are rapidly developing. [Pg.911]

The identity of target elements is established by the energy of the scattered particles after an elastic collision. The number of atoms per unit area, N, is found from the number of detected particles (called the yield, Y) for a given number Q of particles incident on the target. The connection is given by the scattering cross section a(9) by... [Pg.1832]

The method discussed in this chapter allows, in principle, the detection of all conical intersections connecting the ground with the excited state. Assuming that photochemical products are mainly formed through conical intersections, it therefore provides a means to design selection rules for photochemisby. [Pg.329]

Consider again two detection elements, and suppose an ion beam has been dispersed in time such that ions of m/z 100 arrive at each of several elements (Figure 30.5). In this TOF mode, the next ion of m/z 101 has not yet arrived, and the ion of m/z 99 has arrived previously. Although the m/z ions are dispersed in time over a region of space and strike different elements of the detector, they are collected and monitored simultaneously because all of the microchannels are electronically connected. The operation of the microchannel plate is much easier than that of the array because all the elements are monitored as one at the plate, while each element must be monitored separately in the array. The microchannel plate detector is tremendously useful for those cases in which ions... [Pg.215]

Size Isomers. In solution, hGH is a mixture of monomer, dimer, and higher molecular weight oligomers. Furthermore, there are aggregated forms of hGH found in both the pituitary and in the circulation (16,17). The dimeric forms of hGH have been the most carefully studied and there appear to be at least three distinct types of dimer a disulfide dimer connected through interchain disulfide bonds (8) a covalent or irreversible dimer that is detected on sodium dodecylsulfate- (SDS-)polyacrylamide gels (see Electroseparations, Electrophoresis) and is not a disulfide dimer (19,20) and a noncovalent dimer which is easily dissociated into monomeric hGH by treatment with agents that dismpt hydrophobic interactions in proteins (21). In addition, hGH forms a dimeric complex with ( 2). Scatchard analysis has revealed that two ions associate per hGH dimer in a cooperative... [Pg.196]

An on-line concentration, isolation, and Hquid chromatographic separation method for the analysis of trace organics in natural waters has been described (63). Concentration and isolation are accompHshed with two precolumns connected in series the first acts as a filter for removal of interferences the second actually concentrates target solutes. The technique is appHcable even if no selective sorbent is available for the specific analyte of interest. Detection limits of less than 0.1 ppb were achieved for polar herbicides (qv) in the chlorotriazine and phenylurea classes. A novel method for deterrnination of tetracyclines in animal tissues and fluids was developed with sample extraction and cleanup based on tendency of tetracyclines to chelate with divalent metal ions (64). The metal chelate affinity precolumn was connected on-line to reversed-phase hplc column, and detection limits for several different tetracyclines in a variety of matrices were in the 10—50 ppb range. [Pg.245]


See other pages where Connective detection is mentioned: [Pg.247]    [Pg.283]    [Pg.894]    [Pg.127]    [Pg.247]    [Pg.729]    [Pg.247]    [Pg.729]    [Pg.247]    [Pg.96]    [Pg.247]    [Pg.481]    [Pg.152]    [Pg.247]    [Pg.283]    [Pg.894]    [Pg.127]    [Pg.247]    [Pg.729]    [Pg.247]    [Pg.729]    [Pg.247]    [Pg.96]    [Pg.247]    [Pg.481]    [Pg.152]    [Pg.76]    [Pg.299]    [Pg.528]    [Pg.768]    [Pg.1047]    [Pg.1655]    [Pg.1781]    [Pg.102]    [Pg.583]    [Pg.132]    [Pg.473]    [Pg.203]    [Pg.214]    [Pg.436]    [Pg.290]    [Pg.63]    [Pg.206]    [Pg.124]    [Pg.128]    [Pg.426]    [Pg.482]    [Pg.318]    [Pg.31]    [Pg.2330]    [Pg.447]    [Pg.292]    [Pg.299]   
See also in sourсe #XX -- [ Pg.613 ]




SEARCH



Detection Limit for Leakage Rates at Different Connection Positions of a Multistage Pumping System

© 2024 chempedia.info