Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Connection tables external

Almost all chemical information systems work with tlicir own special type of connection table. They often use various formats distinguishing between internal and external connection tables. In most cases, the internal connection tables arc redundant, thus allowing maximum flexibility and increasing the speed of data processing. The external connection tables are usually non-redundant in order to save disk space. Although a connection table can be cprcsented in many different ways, the core remains the same the list of atoms and the list of bonds. Thus, the conversion of one connection table format into another is usually a fairly straightforward task. [Pg.42]

Structure and data storage is shown on the right. A structure table contains the structures, their internal identifiers, and their external identifiers, if any. The structures are stored in a compact binary representation that includes the connection table, the coordinates, the ring information, and any stereochemical, valence, isomer, isotope, or bond information. Certain types of structure-specific information such as polymer or component designations are stored here, whereas other types of structure-specific information (atom- or bond-specific data, and more verbose text data) are stored in their own tables, referenced by the internal identifier, and the atom or bond numbers to which the data correspond. A formula table contains the molecular formula and various atom and atom-type indexes to enhance formula searching and sorting. [Pg.376]

Although SMILES is an entirely equivalent way of storing a connection table of atoms and bonds, it is sometimes desirable to create a traditional connection table, for example, when an external program requires it. The extension functions smiles to symbols and smiles to bonds accept a SMILES string and produce an array of either symbols or bonds. These are discussed in a later section of this chapter. Several implementations of these functions are shown in the Appendix. [Pg.125]

It may seem that some information will have been lost if the original molfile is discarded. For example, the list of atomic symbols and bonds is not stored directly in the vla4.structure table. The cansmiles string, however, does contain this information. It may be necessary for some purposes to extract this information, for example, when an external program does not read SMILES but instead requires a list of atomic symbols and bonds. This is discussed more in the next section. A connection table can... [Pg.130]

Connection tables are the predominant form of internal representation of chemical structures in computer memory. That is, they form the data structures to which various processing algorithms can be applied. Many external connection table file formats also exist for disk storage and exchange of structure representations. [Pg.169]

A string-processing language is used to specify a connection table format. This language allows succinct specification of both the content and encoding of most external formats that we have encountered, but is currently Umited to character-oriented files. [Pg.195]

Chemicals are usually stored in computer-readable format as data which represent a valence structure. For historical reasons, the external format for such data is commonly referred to as a connection table. A majority of connection table formats are simply formatted versions of an internal data structure written out in tabular format. However, a significant number of non-tabular formats are used for external computer representation of chemicals. [Pg.195]

A connection table format can be considered a special-purpose external database format which is used to store a limited amount of chemical information. Our goal is to produce a method which allows accurate description and interpretation of connection tables in the general case. [Pg.196]

System operationality should be such as to take into account possible system and network (Internet) crashes. The user should be given a warning if the system is not working because of an item that is vital for function execution being blocked (internal resources). Additionally, the user will he warned obtrusively if the system is unable to access the network in the course of table booking due to a network crash, as the user should not be allowed to continue with the reservation if a connectivity failure (external resources) prevents the customer s request from being satisfied. [Pg.551]

Different types of polyrotaxanes, depending on how the cyclic and the linear units are connected, have been conceived [6-8, 12], According to the location of the rotaxane unit, polyrotaxanes can be defined as main-chain systems, Types 4, 5, 6, 7, and 8 (rows one and two in Table 1), and side-chain systems, Types 9, 10, 11, and 12 (rows three and four in Table 1). In main-chain polyrotaxanes the rotaxane unit is part of the main chain. In side-chain polyrotaxanes, the rotaxane moiety is located in the side chain as a pendant group. Polyrotaxanes can also be classified as polypseudorotaxanes and true polyrotaxanes, depending on their thermal stability toward dethreading. Polypseudorotaxanes are those without BG (column one in Table 1), in which the rotaxane components can be disassociated from each other by external forces. True polyrotaxanes are those with BG at the chain ends or as in-chain units (column two in Table 1), in which the rotaxane units are thermally stable unless one or more covalent bonds is/are broken. [Pg.278]

The basic setup to determine static interfacial tension based on either the Wilhelmy plate method or the du Noiiy ring method (see Alternate Protocol 2) is shown in Figure D3.6.1. It consists of a force (or pressure) transducer mounted in the top of the tensiometer. A small platinum (Wilhelmy) plate or (du Noiiy) ring can be hooked into the force transducer. The sample container, which in most cases is a simple glass beaker, is located on a pedestal beneath the plate/ring setup. The height of the pedestal can be manually or automatically increased or decreased so that the location of the interface of the fluid sample relative to the ring or plate can be adjusted. The tensiometer should preferably rest on vibration dampers so that external vibrations do not affect the sensitive force transducer. The force transducer and motor are connected to an input/output control box that can be used to transmit the recorded interfacial tension data to an external input device such as a monitor, printer, or computer. The steps outlined below describe measurement at a liquid/gas interface. For a liquid/liquid interface, see the modifications outlined in Alternate Protocol 1. Other variations of the standard Wilhelmy plate method exist (e.g., the inclined plate method), which can also be used to determine static interfacial tension values (see Table D3.6.1). [Pg.633]

Different kinds of dispersions can be formed. Most of them have important applications and have special names (Table 1.1). While there are only five types of interface, we can distinguish ten types of disperse system because we have to discriminate between the continuous, dispersing (external) phase and the dispersed (inner) phase. In some cases this distinction is obvious. Nobody will, for instance, mix up fog with a foam although in both cases a liquid and a gas are involved. In other cases the distinction between continuous and inner phase cannot be made because both phases might form connected networks. Some emulsions for instance tend to form a bicontinuous phase, in which both phases form an interwoven network. [Pg.1]

CPC developed a series of table-top micro reaction systems called CYTOS (Figure 4.22), SEQUOS and OPTIMOS based on a standardized platform. CYTOS is the basic laboratory system with internal and external modularity for high flexibility by running different chemical reactions. The internal modularity offers the realization of variable reaction times up to 45 min by using several residence time units. The external modularity provides a system configuration for a multi-step synthesis. CPC Systems individual connecting principle minimizes the dead volume in the system and provides the reaction with isothermal conditions through the whole system [74, 75]. [Pg.534]

Well-known products include wound dressing, temporary skin, and connective-tissue replacement (BioFill , Gengiflex ) [7]. Numerous groups are working on these applications and investigating the healing effect of this external BC material (Table 2). [Pg.67]


See other pages where Connection tables external is mentioned: [Pg.45]    [Pg.168]    [Pg.78]    [Pg.186]    [Pg.195]    [Pg.196]    [Pg.2821]    [Pg.2821]    [Pg.2821]    [Pg.2822]    [Pg.1010]    [Pg.292]    [Pg.932]    [Pg.43]    [Pg.670]    [Pg.718]    [Pg.294]    [Pg.294]    [Pg.33]    [Pg.232]    [Pg.288]    [Pg.302]    [Pg.330]    [Pg.343]    [Pg.348]    [Pg.355]    [Pg.367]    [Pg.372]    [Pg.400]    [Pg.435]    [Pg.215]    [Pg.734]    [Pg.240]    [Pg.30]    [Pg.526]   
See also in sourсe #XX -- [ Pg.4 , Pg.2821 ]




SEARCH



Connection table

Connectivity table

© 2024 chempedia.info