Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Concentration monitoring

The concentrations monitored by these instruments range from a few milligrams to 4000 mg/m A flow diagram of a beta gauge particulate monitor is shown in Fig. 13.41. [Pg.1291]

The general operation of the pilot scale reactor has be previously described by Pareek et. al. [3]. However, modifications were required to allow the injection of the gas and liquid tracers, and their subsequent detection at the outlets. The liquid tracer, 5mL Methyl blue solution (lOgL" ), was injected via a syringe inserted into the liquid feed line. Outlet samples were measured with a Shimadzu 1601 UV-Vis Spectrophotometer at a wavelength of 635nm. A pulse (20mL) of helium gas tracer was introduced using an automated control system, with the outlet concentration monitored in real-time with a thermal conductivity detector. Runs were carried out based on a two-level... [Pg.669]

Initial antibiotic choice should always cover gram-positive organisms (e.g., vancomycin 20 mg/kg intravenously with serum concentration monitoring or cefazolin 20 mg/kg intravenously 3 times... [Pg.397]

Gram-negative coverage is indicated for patients with diabetes, HIV infection, prosthetic valves, or those receiving immunosuppressive agents (gentamicin 2 mg/kg intravenously with serum concentration monitoring). [Pg.397]

Develop a plan for monitoring therapeutic outcomes, focusing on the individual symptom profile and level of function of each patient. Include a plan for dosage adjustments or alternate therapy if the patient fails to respond adequately. Include serum drug concentration monitoring as appropriate. [Pg.603]

One approach to the study of solubility is to evaluate the time dependence of the solubilization process, such as is conducted in the dissolution testing of dosage forms [70], In this work, the amount of drug substance that becomes dissolved per unit time under standard conditions is followed. Within the accepted model for pharmaceutical dissolution, the rate-limiting step is the transport of solute away from the interfacial layer at the dissolving solid into the bulk solution. To measure the intrinsic dissolution rate of a drug, the compound is normally compressed into a special die to a condition of zero porosity. The system is immersed into the solvent reservoir, and the concentration monitored as a function of time. Use of this procedure yields a dissolution rate parameter that is intrinsic to the compound under study and that is considered an important parameter in the preformulation process. A critical evaluation of the intrinsic dissolution methodology and interpretation is available [71]. [Pg.26]

Several cases of sudden death have been reported in children and adolescents taking desipramine. A baseline electrocardiogram (ECG) is recommended before initiating a TCA in children and adolescents, and an additional ECG is advised when steady-state plasma concentrations are achieved. TCA plasma concentration monitoring is critical to ensure safety. [Pg.807]

Phenol has been measured in effluents (up to 53 ppm), ambient water (from 1.5 to >100 ppb), drinking water (not quantified), groundwater (from 1.9 to >10 ppb), rain (0.075-1.2 ppb), sediment (>10 ppb), and ambient air (0.03-44 ppb). Occupational exposures occur through inhalation and dermal exposure air concentrations monitored in various workplaces range from 0.1 to 12.5 mg/m3 (0.03-32 ppm). Occupational as well as consumer exposure may also occur through dermal contact with phenol or phenol-containing products. [Pg.163]

S. O Keeffe, C. Eitzpatrick, E. Lewis, An optical fibre based ultra violet and visible absorption spectroscopy system for ozone concentration monitoring. Sens. Actuators B, 125, 372-378 (2007). [Pg.105]

The temporal variability of these substances has been analysed as a function of annual and weekly trends. Weekly concentrations monitored for almost 2 years in... [Pg.451]

Therapy with leucovorin/5-FU must not be initiated or continued in patients who have symptoms of Gl toxicity of any severity, until those symptoms have completely resolved. Patients with diarrhea must be monitored with particular care until the diarrhea has resolved, as rapid clinical deterioration leading to death can occur. Methotrexate concentrations Monitoring of the serum methotrexate concentration is essential in determining the optimal dose and duration of treatment with leucovorin. Delayed methotrexate excretion may be caused by a third space fluid accumulation, renal insufficiency, or inadequate hydration. Under such circumstances, higher doses of leucovorin or prolonged administration may be indicated. Doses higher than those recommended for oral use must be given IV. [Pg.68]

Drug interactions Serious and/or life-threatening drug interactions could occur between amprenavir and amiodarone, lidocaine (systemic), tricyclic antidepressants, and quinidine. Concentration monitoring of these agents is recommended if these agents are used concomitantly with amprenavir. [Pg.1823]

Blood levels - Blood level monitoring of cyclosporine is a useful and essential component in patient management. While no fixed relationships have been established, blood concentration monitoring may assist in the clinical evaluation of rejection and toxicity, dose adjustments, and the assessment of compliance. [Pg.1966]

These optical probes are the most universally applicable in situ devices for on-line biomass monitoring up to now [15,16]. Konstaninov et al. [17] tested several absorbance and scattering sensors for real-time biomass concentration monitoring in mammalian cell cultivation processes and Hatch and Veilleux [18] compared optical density probes with oxygen uptake rates, packed cell volume, and off-line cell mass monitoring in commercial fed-batch fermentations of Saccharomyces cerevisiae [19]. In order to minimize influencing effects, special chemometric data treatment is necessary [20]. [Pg.22]

O NMR spectroscopy, 185-6 solid state stractures, 1061-3 synthesis, 1057-9 /r-Peroxo complexes solid state stmctures, 1064-8 synthesis, 1059-61 Peroxodisulfate concentration monitoring, 744 etching formulations, 623 Peroxomonosulfate, concentration monitoring, 744... [Pg.1480]


See other pages where Concentration monitoring is mentioned: [Pg.52]    [Pg.806]    [Pg.926]    [Pg.223]    [Pg.250]    [Pg.594]    [Pg.599]    [Pg.599]    [Pg.600]    [Pg.601]    [Pg.602]    [Pg.1114]    [Pg.1114]    [Pg.213]    [Pg.41]    [Pg.555]    [Pg.599]    [Pg.599]    [Pg.653]    [Pg.814]    [Pg.269]    [Pg.76]    [Pg.281]    [Pg.71]    [Pg.429]    [Pg.301]    [Pg.115]    [Pg.1940]    [Pg.1941]    [Pg.86]    [Pg.52]    [Pg.512]    [Pg.382]   


SEARCH



Airborne concentrations monitoring

Ammonia concentration monitoring

Antidepressants plasma concentration monitoring

Antiepileptics blood concentration, monitoring

Antimicrobial serum concentration monitoring

Atmospheric concentration monitoring

Concentration metabolic monitoring

Concentration monitors

Digoxin serum concentration monitoring

Drug concentration monitoring

Gas concentration monitoring

Gentamicin serum concentration monitoring

Lactate concentrations monitoring

Monitoring methods Proton concentration

Peak concentrations, monitoring

Pharmacokinetics drug concentration monitoring

Plasma drug concentration monitoring

Reactant concentration monitoring

Serum concentration monitoring

Surface concentration monitoring

Tobramycin serum concentration monitoring

Tricyclic antidepressants plasma concentration monitoring

Vancomycin serum concentration monitoring

© 2024 chempedia.info