Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Software COMPOSER

A number of other software packages are available to predict NMR spectra. The use of large NMR spectral databases is the most popular approach it utilizes assigned chemical structures. In an advanced approach, parameters such as solvent information can be used to refine the accuracy of the prediction. A typical application works with tables of experimental chemical shifts from experimental NMR spectra. Each shift value is assigned to a specific structural fragment. The query structure is dissected into fragments that are compared with the fragments in the database. For each coincidence, the experimental chemical shift from the database is used to compose the final set of chemical shifts for the... [Pg.519]

The use of UNIFAC for estimating activity coefficients in binary and multicomponent organic and organic—water systems is recommended for those systems composed of nonelectrolyte, nonpolymer substances for which only stmctural information is known. UNIFAC is not recommended for systems for which some reUable experimental data are available. The method, including revisions through 1987 (39), is available in commercial software packages such as AspenPlus (174). [Pg.253]

Five articles on polysaccharide helices solved prior to 1979 have appeared in the volumes published between 1967 and 1982.2-6 The first was a review on X-ray fiber diffraction and its application to cellulose, chitin, amylose, and related structures, and the rest were bibliographic accounts. Since then, X-ray structures of several new polysaccharides composed of simple to complex repeating units have been successfully determined, thanks to technological advances in fiber-diffraction techniques, the availability of fast and powerful computers, and the development of sophisticated software. Also, some old models have been either re-... [Pg.312]

Due to its modularity, the software comes in many parts (shown in Fig. 9). The Chemkin package is composed of four important pieces the Interpreter, the Thermodynamic Data Base, the Linking File, and the Gas-Phase Subroutine Library. The Interpreter is a program that first reads the user s symbolic description of the reaction mechanism. It then extracts thermodynamic information for the species involved from the Thermodynamic Data Base. The user may add to or modify the information in the data base by input to the Interpreter. In addition to printed output, the Interpreter writes a Linking File, which contains all the pertinent information on the elements, species, and reactions in the mechanism. [Pg.348]

At the end of the 2D experiment, we will have acquired a set of N FIDs composed of quadrature data points, with N /2 points from channel A and points from channel B, acquired with sequential (alternate) sampling. How the data are processed is critical for a successful outcome. The data processing involves (a) dc (direct current) correction (performed automatically by the instrument software), (b) apodization (window multiplication) of the <2 time-domain data, (c) Fourier transformation and phase correction, (d) window multiplication of the t domain data and phase correction (unless it is a magnitude or a power-mode spectrum, in which case phase correction is not required), (e) complex Fourier transformation in Fu (f) coaddition of real and imaginary data (if phase-sensitive representation is required) to give a magnitude (M) or a power-mode (P) spectrum. Additional steps may be tilting, symmetrization, and calculation of projections. A schematic representation of the steps involved is presented in Fig. 3.5. [Pg.163]

Most clinical data management systems used for clinical trials today store their data in relational database software such as Oracle or Microsoft SQL Server. A relational database is composed of a set of rectangular data matrices called tables that relate or associate with one another by certain key fields. The language most often used to work with relational databases is structured query language (SQL). The SAS/ACCESS SQL Pass-Through Facility and the SAS/ACCESS LIBNAME engine are the two methods that SAS provides for extracting data from relational databases. [Pg.42]

We can zoom into, or refine, the action to see more detail. What was one action is now seen to be composed of several actions (see Figure 6.8). Each of these actions can be split again into smaller ones, into as much detail as you like. Some of the actions might be performed by software others might be performed by some mixture of software, hardware, and people still others might be the interactions between those things. At any level—deep inside the software or at the overall business level—we can treat them the same way. Catalysis is a fractal method It works in the same way at any scale. [Pg.249]

What is new about components If they are reusable software pieces, how are they different from modules If they are like objects, in what ways are they different At the most basic level, components are parts that can be composed with others to build something bigger. Let s start with some basic definitions. [Pg.409]

The components and their lines of communication mirror those of the business. The diagram could represent a business structure of departments and flows of work, or a software structure of components and connectors. Just as departments are composed of teams and people, so a closer look at ary one of these components would reveal that it is built from smaller ones. [Pg.430]

EMOS is a combined hardware and software system that gathers chemical and electrical parameters in real-time and processes them so that close process monitoring is maintained along with information that will lead to process optimisation (see Fig. 8.1). EMOS is composed of three main components ... [Pg.119]

To do this, we developed a computer software system composed of several major program blocks. These programs and their functions are ... [Pg.235]

The traditional HPLC instrument is composed of two different parts the first part separates the components of the sample and the other part accomplishes the detection of the components separated. The part of the HPLC carrying out the separation contains a column, an injection device and the eluent delivery system (pump with filters, degasser and transfer tubing, eventually a mixer for gradient elution). One or more detectors, a signal output device coupled with appropriate software, are responsible for detection and primary data evaluation. Pumps deliver the eluent or the different components of the eluent into the column with a precise, constant and reproducible flow rate. [Pg.42]

Oread Lite Version 9.2 - This is the version of Capture and PSpice that was used to compose this manual. The software is included courtesy of Cadence Design Systems, Inc.. [Pg.641]

A smart closed-loop system is composed of a heating/pressure device, such as a press or autoclave, sensors able to gather data in situ from the composite part, and smart software that collects the sensor information, interprets it, and then makes decisions that control the fabrication device. The smart software combines both the predictions of the processing model and the insight of operator experience. Figure 4.20 is a schematic diagram of the FDEMS... [Pg.154]

A computer system is composed of software and hardware, equipment, a processor, and a user, and it is used to execute a specific procedure. Regardless of whether the computer system is developed in-house or by a contractor or purchased off the shelf, establishing documented end-user requirements is extremely important for computer systems validation. Without first establishing end-user needs and intended use, it is virtually impossible to confirm that the system can consistently meet them. Once established, it should obtain evidence that the computer system implements those needs correctly and that they are traceable to system design requirements and specifications. It is important that the end-user requirements specifications take into account predicate rules [12]. [Pg.830]

E° [equation (15.4)] is also referred to as the offset, the zero potential point, or the isopotential point, since theoretically it is defined as the pH that has no temperature dependence. Most pH electrode manufacturers design their isopotential point to be 0 mV at pH 7 to correspond with the temperature software in most pH meters. The offset potential is often displayed after calibration as an indication of electrode performance. Typical readings should be about 0 30 mV in a pH 7 buffer. In reality, E° is composed of several single potentials, each of which has a slight temperature coefficient. These potentials are sources of error in temperature compensation algorithms. [Pg.237]


See other pages where Software COMPOSER is mentioned: [Pg.78]    [Pg.410]    [Pg.218]    [Pg.78]    [Pg.410]    [Pg.218]    [Pg.120]    [Pg.159]    [Pg.34]    [Pg.128]    [Pg.1303]    [Pg.21]    [Pg.395]    [Pg.40]    [Pg.358]    [Pg.448]    [Pg.128]    [Pg.21]    [Pg.409]    [Pg.410]    [Pg.739]    [Pg.739]    [Pg.298]    [Pg.298]    [Pg.103]    [Pg.160]    [Pg.72]    [Pg.678]    [Pg.245]    [Pg.189]    [Pg.471]    [Pg.3]    [Pg.132]    [Pg.137]    [Pg.91]    [Pg.110]    [Pg.1028]   
See also in sourсe #XX -- [ Pg.134 ]




SEARCH



COMPOSER

© 2024 chempedia.info