Figure 12.24 Schematic diagram of the multidimensional packed capillary to open tubular column SFC-SFC system. Reprinted from Analytical Chemistry, 62, Z. Juvancz et al., Multidimensional packed capillary coupled to open tubular column supercritical fluid chromatography using a valve-switching interface , pp. 1384-1388, copyright 1990, with permission from the American Chemical Society. Figure 12.24 Schematic diagram of the multidimensional packed capillary to open tubular column SFC-SFC system. Reprinted from Analytical Chemistry, 62, Z. Juvancz et al., Multidimensional packed capillary coupled to open tubular column supercritical fluid chromatography using a valve-switching interface , pp. 1384-1388, copyright 1990, with permission from the American Chemical Society.
This method requires about 40 g of tobacco which are extracted with ethyl acetate in the presence of ascorbic acid. A trace amount of C-NDELA is added as an internal standard for quantitative analytical work. The filtered extract is concentrated and NDELA is enriched by column chromatography of the concentrate on silica gel. The residues of fractions with p-activity are pooled and redissolved in acetonitrile. Initially, we attempted to separate NDELA on a 3% OV-225 Chromosorb W HP column at 210 C using a GC-TEA system with direct interface similar to the technique developed by Edwards a. for the analysis of NDELA in urine (18). We found this method satisfactory for reference compounds however, it was not useful for an optimal separation of NDELA from the crude concentrate of the tobacco extract (Figure 4). Therefore, we silylated the crude concentrate with BSTFA and an aliquot was analyzed by GC-TEA with direct interface. The chromatographic conditions were 6 ft glass column filled with 3% OV-... [Pg.252]

The concept of peak capacity is rather universal in instrumental analytical chemistry. For example, one can resolve components in time as in column chromatography or space, similar to the planar separation systems however, the concept transcends chromatography. Mass spectrometry, for example, a powerful detection method, which is often the detector of choice for complex samples after separation by chromatography, is a separation system itself. Mass spectrometry can separate samples in time when the mass filter is scanned, for example, when the mass-to-charge ratio is scanned in a quadrupole detector. The sample can also be separated in time with a time-of-flight (TOF) mass detector so that the arrival time is related to the mass-to-charge ratio. [Pg.16]

Elution with salt pulses A multiple step elution is performed by the introduction of, for example, 5%, 10%, 25%, 50%, and 100% of 1.5 M sodium chloride in 19 mM phosphate buffer (pH 2.5) containing 5% methanol. Each step is for 10 min and run at 0.5 mL/min. This elution method compromises analytical system dimensionality, as the peak capacity of the ion-exchange chromatography (IEX) step is equal at most to the number of salt steps. However, in the second dimension only one or two columns are needed and there is no particular limitation in the second dimension separation time as peptides are eluted in portions in a controlled manner. However, the number of salt steps is limited by the total analysis time. In this case the multidimensional system is relatively simple. [Pg.215]

The optimum conditions for capillary chromatography of material heart cut from a packed column demand a highly sophisticated programming system. The software provided with the model 8700 provides this, allowing methods to be linked so that pre-column and analytical column separations are performed under optimum conditions. [Pg.66]

In recent years h.p.l.c. has become a valuable chromatographic tool for analytical and preparative scale work. In this latter area the separation of isomers (structural, diastereoisomeric, and enantiomeric) has been possible by the selection of appropriate column packing material and solvent systems. However, the equipment, operating costs, and column packing materials are more expensive than those in t.l.c., g.l.c. and conventional liquid-solid column chromatography. [Pg.199]

In principle, h.p.Lc. arose from conventional liquid column chromatography, following the development of g.l.c. and realisation that it was a rapid and accurate analytical method. This led to a reappraisal of the liquid column chromatographic system, which in turn resulted in research developments in instrument design and in the manufacture of column-packing materials. These now have precise specifications to make them suitable for adsorption, normal and reversed phase partition, ion exchange, gel permeation, and more recently affinity chromatography. [Pg.232]

The optimum conditions for capillary chromatography of material heart-cut from a packed column demand a highly sophisticated programming system. The software provided with the model 8700 provides this, allowing methods to be linked so that pre-column and analytical column separations are performed under optimum conditions. Following the first run, in which components are transferred from the pre-column to the on-line cold trap, the system will reset to a second method and, on becoming ready, the cold trap is desorbed and the analytical run automatically started. [Pg.24]


See other pages where Column chromatography analytical systems is mentioned: [Pg.274]    [Pg.290]    [Pg.246]    [Pg.375]    [Pg.422]    [Pg.231]    [Pg.232]    [Pg.108]    [Pg.225]    [Pg.1253]    [Pg.135]    [Pg.262]    [Pg.375]    [Pg.208]    [Pg.430]    [Pg.236]    [Pg.126]    [Pg.47]    [Pg.400]    [Pg.342]    [Pg.1253]    [Pg.58]    [Pg.376]    [Pg.381]    [Pg.1]    [Pg.290]    [Pg.223]    [Pg.72]    [Pg.287]    [Pg.301]    [Pg.133]    [Pg.179]    [Pg.231]    [Pg.586]    [Pg.189]    [Pg.85]    [Pg.81]    [Pg.58]    [Pg.377]    [Pg.1972]   