Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Clean rooms cleaning

Appendix A and Appendix B offer a template for working in a clean environment as well as clean-room cleaning procedures. Procedures should be modified with caution to suit a particular project. [Pg.225]

All metal parts exposed to the room are made of stainless steel and motors and transmissions are IP 65 to withstand the eflfect of the cleaning agents. The design also takes into account the special considerations necessary for food processing machinery with regards to easy accessibility to all parts and the lack of corners, edges, pockets or other food traps , so that the mechanical system can be easily cleaned. [Pg.592]

Figure Bl.19.13. (a) Tliree STM images of a Pt(l 11) surface covered witli hydrocarbon species generated by exposure to propene. Images taken in constant-height mode. (A) after adsorption at room temperature. The propylidyne (=C-CH2-CH2) species that fomied was too mobile on the surface to be visible. The surface looks similar to that of the clean surface. Terraces ( 10 mn wide) and monatomic steps are the only visible features. (B) After heating the adsorbed propylidyne to 550 K, clusters fonn by polymerization of the C H... Figure Bl.19.13. (a) Tliree STM images of a Pt(l 11) surface covered witli hydrocarbon species generated by exposure to propene. Images taken in constant-height mode. (A) after adsorption at room temperature. The propylidyne (=C-CH2-CH2) species that fomied was too mobile on the surface to be visible. The surface looks similar to that of the clean surface. Terraces ( 10 mn wide) and monatomic steps are the only visible features. (B) After heating the adsorbed propylidyne to 550 K, clusters fonn by polymerization of the C H...
Place an intimate mixture of 125 g. of powdered, anhydrous zinc chloride and 26-5 g. of acetophenonephenylhydrazone in a tall 500 ml. beaker in an oil bath at 170°. Stir the mixture vigorously by hand. After 3-4 minutes the mass becomes hquid and evolution of white fumes commences. Remove the beaker from the bath and stir the mixture for 5 minutes. Then stir in 100 g. of clean, white sand in order to prevent solidification to a hard mass. Digest the mixture for 12-16 hours on a water bath with 400 ml. of water and 12 ml. of concentrated hydrochloric acid in order to dissolve the zinc chloride. Filter off the sand and the crude 2-phenylindole, and boil the solids with 300 ml. of rectified spirit. Treat the hot mixture with a little decolourising carbon and filter through a pre-heated Buchner funnel wash the residue with 40 ml. of hot rectified spirit. Cool the combined filtrates to room temperature, filter off the 2-phenylindole and wash it three times with 10 ml. portions of cold alcohol. Dry in a vacuum desiccator over anhydrous calcium chloride. The yield of pure 2-phenylindole, m.p. 188-189°, is 16 g. [Pg.852]

That s it The MDA has now been made. The solution is completely clear with not one iota of tar produced, and all of this achieved at room temperature with no pressure needed. Strike told you this was good. The solution is now cleaned up a little and the MDA isolated. [Pg.98]

Cleaning formulations Cleaning products Cleaning solvents Cleanness Clean rooms... [Pg.226]

Higher or lower quaUty at more or less cost will meet the needs of some consumers. Acetone is often produced under contract to meet customer specifications which are different from those of ASTM D329. Some specialty grades are analy2ed reagent, isotopicaHy labeled, clean room, Hquid chromatography, spectroscopic, ACS reagent (48), semiconductor (low metals), and Federal Specification 0-A-51G. [Pg.98]

California Department of Consumer Affairs, Clean Your Room, Compendium on Indoor Air Pollution, Sacramento, Calif., 1982, p. III.EI—III.E.II. [Pg.383]

Polyesters are also used in continuous filament spunbonded nonwovens (see Nonwoven fabrics). Reemay spunbonded fabric is composed of continuous filament PET with a polyester copolymer binder. These spunbonded fabrics are available in a wide range of thicknesses and basis weights and can be used for electrical insulation, coated fabric substrates, disposable apparel for clean rooms, hospitals, and geotextiles (qv). [Pg.334]

Monel and nickel are the preferred materials of constmction for cylinders and deHvery systems however, copper, brass, steel, and stainless steel can be used at room temperature, providing that these metals are cleaned, dried, and passivated with a fluoride film prior to use. Studies have shown that fluorine passivation of stainless steel and subsequent formation of an iron fluoride layer prior to WF exposure prevents reaction between the WF and the stainless steel surface (23). [Pg.258]

The emissivity, S, is the ratio of the radiant emittance of a body to that of a blackbody at the same temperature. Kirchhoff s law requires that a = e for aH bodies at thermal equHibrium. For a blackbody, a = e = 1. Near room temperature, most clean metals have emissivities below 0.1, and most nonmetals have emissivities above 0.9. This description is of the spectraHy integrated (or total) absorptivity, reflectivity, transmissivity, and emissivity. These terms can also be defined as spectral properties, functions of wavelength or wavenumber, and the relations hold for the spectral properties as weH (71,74—76). [Pg.202]

Other appHcations of firefly hioluminescence include measurement of the activity of bacteria in secondary sewage treatment activated sludge (296,297), detection of bacteria in clean rooms and operating rooms, measurement of bacteria in bottled foods, beverages (298), and pharmaceuticals (299), determination of the antimicrobial activity of potential dmgs (300), determination of the viabiHty of seeds (301), and measuring marine biomass concentrations as a function of ocean depth or geographical location (302). [Pg.275]

Ion implantation (qv) direcdy inserts nitrogen into metal surfaces. A carefully poHshed and cleaned metal surface at room temperature in a vacuum (-- 0.133 mPa (l-) m Hg)) can be directly implanted with 80-keV nitrogen ions (10) (see Metal surface treatments, case hardening). In an alternative synthesis, argon ions (Ar ) of 8 keV can be used to ionize gas-phase nitrogen to obtain the same results (17). [Pg.54]

Nonwoven wipe categories include products for babies and adults, the food service and electronics industries, medical and clean room appHcations, industrial cleaning, computer diskettes, and household products such as dusters, tea towels, shoe cleaning cloths, towelettes, and hand towels. Nonwoven fabrics are used to filter air, water, petroleum (qv), food, and beverages. Nonwovens loaded with abrasives, cleansers, or finishes can be found in a variety of products used by many industries and in many homes to scour or poHsh. Also, a majority of garments designed to protect industrial workers and consumers from hazardous environments are made from nonwoven fabrics. [Pg.158]


See other pages where Clean rooms cleaning is mentioned: [Pg.439]    [Pg.1687]    [Pg.2707]    [Pg.2931]    [Pg.193]    [Pg.197]    [Pg.323]    [Pg.146]    [Pg.238]    [Pg.219]    [Pg.374]    [Pg.63]    [Pg.226]    [Pg.322]    [Pg.363]    [Pg.378]    [Pg.440]    [Pg.72]    [Pg.73]    [Pg.311]    [Pg.355]    [Pg.355]    [Pg.438]    [Pg.524]    [Pg.525]    [Pg.525]    [Pg.441]    [Pg.137]    [Pg.174]    [Pg.337]    [Pg.75]    [Pg.76]    [Pg.77]    [Pg.78]    [Pg.164]    [Pg.9]    [Pg.6]    [Pg.335]   
See also in sourсe #XX -- [ Pg.385 , Pg.395 , Pg.699 , Pg.766 ]




SEARCH



Analysis clean room

Blast cleaning room

Buildings clean rooms

Clean Room Applications

Clean Room Flammability Standard

Clean room

Clean room ceiling

Clean room classification

Clean room environment

Clean room equipment

Clean room equipment manufacturers

Clean room exposure

Clean room filters

Clean room microbiological evaluation

Clean room protection

Clean room standards

Clean room technology

Clean room values

Clean room, use

Clean rooms design

Clean rooms disinfection

Clean rooms modeling

Clean-room conditions

Clean-room conditions validation

Disinfectants clean rooms

Fire extinguishers clean rooms

Laminar flow clean rooms

Premises clean rooms

Semiconductor industry, Clean Room

© 2024 chempedia.info