Analytes are introduced into mass spectrometers in gas, liquid, or solid states. In the latter two cases, volatilization must be accomplished either prior to or accompanying ionization. Many ionization techniques are available to produce charged species from analytes the most common ones are electron ionization (electron impact ionization), chemical ionization, matrix-assisted laser desoprtion ionization and atmospheric-pressure ionization (electrospray, atmospheric-pressure chemical ionization, and atmospheric-pressure photoionization). Electron ionization utilizes accelerated electrons (70 eV) colliding with gaseous analyte... [Pg.200]

El and Cl methods can be used if the compound to be studied is sufficiently volatile and stable to be vaporized intact. However, only 20% of the organics found in surface water are volatile enough to be amenable to GC-EI-MS or GC-CI-MS. Today, there are a variety of other ionization techniques available electrospray ionization (ESI), atmospheric pressure chemical ionization, matrix-assisted laser desorption ionization, and fast atom bombardment. Each of these has its advantages and disadvantages. A simple guideline to the most likely optimum ionization technique for a given class of substance is given in Table 1. [Pg.2798]

Schroder, E. Munster, H. Bndzikie-wicz, H. Ionization by Fast Atom Bombardment - a Chemical Ionization (Matrix) Process Ion the Gas Phase Org. Mass Spectrom. 1986,27,707-715. [Pg.501]

El = electron ionization Cl = chemical ionization ES = electrospray APCI = atmospheric-pressure chemical ionization MALDI = matrix-assisted laser desorption ionization PT = plasma torch (isotope ratios) TI = thermal (surface) ionization (isotope ratios). [Pg.280]

GC/MS has been employed by Demeter et al. (1978) to quantitatively detect low-ppb levels of a- and P-endosulfan in human serum, urine, and liver. This technique could not separate a- and P-isomers, and limited sensitivity confined its use to toxicological analysis following exposures to high levels of endosulfan. More recently, Le Bel and Williams (1986) and Williams et al. (1988) employed GC/MS to confirm qualitatively the presence of a-endosulfan in adipose tissue previously analyzed quantitatively by GC/ECD. These studies indicate that GC/MS is not as sensitive as GC/ECD. Mariani et al. (1995) have used GC in conjunction with negative ion chemical ionization mass spectrometry to determine alpha- and beta-endosulfan in plasma and brain samples with limits of detection reported to be 5 ppb in each matrix. Details of commonly used analytical methods for several types of biological media are presented in Table 6-1. [Pg.249]

Due to the high mass, low volatility, and thermal instability of chlorophylls and derivatives, molecular weight determination by electron impact (El) MS is not recommended. Desorption-ionization MS techniques such as chemical ionization, secondary ion MS, fast-atom bombardment (FAB), field, plasma- and matrix-assisted laser desorption have been very effective for molecular ion detection in the characterization of tetrapyrroles. These techniques do not require sample vaporization prior to ionization and they are effective tools for allomerization studies. [Pg.438]

Figure 2.1 Mass spectrometric approach. Dl, direct inlet GC, gas chromatography HPLC, high performance liquid chromatography CZE, capillary zone electrophoresis El, electron ionization Cl, chemical ionization ESI, electrospray ionization DESI, desorption electrospray ionization APCI, atmospheric pressure chemical ionization MALDI, matrix assisted laser desorption ionization B, magnetic analyzer E, electrostatic analyzer... Figure 2.1 Mass spectrometric approach. Dl, direct inlet GC, gas chromatography HPLC, high performance liquid chromatography CZE, capillary zone electrophoresis El, electron ionization Cl, chemical ionization ESI, electrospray ionization DESI, desorption electrospray ionization APCI, atmospheric pressure chemical ionization MALDI, matrix assisted laser desorption ionization B, magnetic analyzer E, electrostatic analyzer...
DGE a AC AMS APCI API AP-MALDI APPI ASAP BIRD c CAD CE CF CF-FAB Cl CID cw CZE Da DAPCI DART DC DE DESI DIOS DTIMS EC ECD El ELDI EM ESI ETD eV f FAB FAIMS FD FI FT FTICR two-dimensional gel electrophoresis atto, 10 18 alternating current accelerator mass spectrometry atmospheric pressure chemical ionization atmospheric pressure ionization atmospheric pressure matrix-assisted laser desorption/ionization atmospheric pressure photoionization atmospheric-pressure solids analysis probe blackbody infrared radiative dissociation centi, 10-2 collision-activated dissociation capillary electrophoresis continuous flow continuous flow fast atom bombardment chemical ionization collision-induced dissociation continuous wave capillary zone electrophoresis dalton desorption atmospheric pressure chemical ionization direct analysis in real time direct current delayed extraction desorption electrospray ionization desorption/ionization on silicon drift tube ion mobility spectrometry electrochromatography electron capture dissociation electron ionization electrospray-assisted laser desorption/ionization electron multiplier electrospray ionization electron transfer dissociation electron volt femto, 1CT15 fast atom bombardment field asymmetric waveform ion mobility spectrometry field desorption field ionization Fourier transform Fourier transform ion cyclotron resonance... [Pg.11]

ESI is more likely to exhibit matrix effects than is atmospheric pressure chemical ionization (APCI), Mei et al. [115, 124] reported that matrix effects could be seen in both APCI and ESI assays. In general, these matrix effects can be detected by using the post-column infusion technique as described above. [Pg.413]

Tesche, F. Pickard, V. Matrix effects during analysis of plasma samples by electrospray and atmospheric pressure chemical ionization mass spectrometry practical approaches to their elimination. Rapid Commun Mass Spectrom 2003, 17, 1950—1957. [Pg.426]

The dominating method of ion formation in metabolic flux analysis is electron impact. It might be supplemented in the future by novel methods, such as matrix assisted laser desorption and electrospray. Additional techniques such as chemical ionization, fast atom bombardment or inductively coupled plasma ionization are only of minor importance and not further discussed in this context. [Pg.51]

Figure 14.1 Schematic view of a mass spectrometer. Its basic parts are ion source, mass analyzer, and detector. Selected principles realized in modern mass spectrometers are assigned El—electron impact. Cl—chemical ionization, FAB—fast atom bombardment, ESI—electrospray ionization, MALDI—matrix-assisted laser desorption/ionization. Different combinations of ion formation with mass separation can be realized. Figure 14.1 Schematic view of a mass spectrometer. Its basic parts are ion source, mass analyzer, and detector. Selected principles realized in modern mass spectrometers are assigned El—electron impact. Cl—chemical ionization, FAB—fast atom bombardment, ESI—electrospray ionization, MALDI—matrix-assisted laser desorption/ionization. Different combinations of ion formation with mass separation can be realized.
There are many different ionization techniques available to produce charged molecules in the gas phase, ranging from simple electron (impact) ionization (El) and chemical ionization (Cl) to a variety of desorption ionization techniques with acronyms such as fast atom bombardment (FAB), plasma desorption (PD), electrospray (ES), and matrix-assisted laser desorption ionization (MALDI) (Mano and Goto 2003). [Pg.151]

OPA, o-phthalaldehyde NQS, -naphthoquinone-4-sulfonate ex, excitation em, emission ISP, lonspray APCI, atmospheric pressure chemical ionization MSPD, matrix soid-phase dispersion SPE, solid-phase extraction deprtn, deproteinization acidfn, acidification RP, reversed phase NR, not reported. [Pg.885]

Ion genera lion can be achieved in a number of ways electron impact (Eh ionization, chemical ionization (CI). fas I atom bombardment (FAB), matrix assisted taser desorption ionization (MAI.DI), eleclrospray ionization (ESI) and atmospheric pressure chemical ionization (APC I are the most common methods,... [Pg.149]


See other pages where Chemical ionization matrix is mentioned: [Pg.405]    [Pg.405]    [Pg.147]    [Pg.359]    [Pg.468]    [Pg.57]    [Pg.495]    [Pg.1003]    [Pg.48]    [Pg.60]    [Pg.60]    [Pg.402]    [Pg.344]    [Pg.702]    [Pg.72]    [Pg.381]    [Pg.386]    [Pg.525]    [Pg.136]    [Pg.150]    [Pg.150]    [Pg.213]    [Pg.444]    [Pg.693]    [Pg.70]    [Pg.147]    [Pg.727]    [Pg.496]   