Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chart speed, effect

Figure 8. Original tracings showing the effects of (R)a-methylhistamine (MHA, pM), thioperamide (TH, pM), the selective a2 adrenoceptor agonist UK-14304 (UK, nM) and the a2-adrenoceptor antagonist idazoxan (ID, pM) on different in vitro assays from the guinea pig ileum A) Electrically-evoked longitudinal contractions of the whole ileum B) Peristaltic waves of the perfused ileum, C) Reflex-evoked circular muscle contractions Vertical calibrations represent (A and C) centimeters of isotonic contractions or (B) changes in perfusion pressure. Horizontal calibration is the chart speed, w = washing of the preparation... Figure 8. Original tracings showing the effects of (R)a-methylhistamine (MHA, pM), thioperamide (TH, pM), the selective a2 adrenoceptor agonist UK-14304 (UK, nM) and the a2-adrenoceptor antagonist idazoxan (ID, pM) on different in vitro assays from the guinea pig ileum A) Electrically-evoked longitudinal contractions of the whole ileum B) Peristaltic waves of the perfused ileum, C) Reflex-evoked circular muscle contractions Vertical calibrations represent (A and C) centimeters of isotonic contractions or (B) changes in perfusion pressure. Horizontal calibration is the chart speed, w = washing of the preparation...
This approach is quite useful where clean fractions are desired and used for further experimental work. When recycle is used, it is normal practice to increase detector sensitivity and decrease chart speed during appropriate cycles in order to accommodate for the effects of band broadening and to obtain a better visual judgment of the resulting chromatogram. [Pg.223]

Fig 1 The effect of injection volume and cryogenic focusing, head space on column injection test mixture of (Table 1). Operating conditions temrera-ture 30 °C 3 min., 8°/min to 100 hydrogen carrier at 50 cm/sec (lOO °C), chart speed 1 cm/min. A - 50 4.injection without liquid nitrogen B -100/4. [Pg.730]

Since the peak width on the baseline may be affected by adsorption and tailing effects, the peak s half width is used in the area calculation. This procedure for peak area calculation should only be applied to symmetrical signals. The area thus calculated is proportional to the concentration but slightly smaller than the true value. For an accurate determination of the half widths, a high chart speed must be chosen. [Pg.332]

CAM, 3-19, 3-52 CARC surfaces, 1-4 Chemical agents wind speed effects on, 3-17 persistency, 2-12 Chemical hazard prediction adjusted, 2-11 flow chart, 2-5, 2-8 plotting, 2-4 Type A, case a, 2-7 Type A, case b, 2-7... [Pg.178]

Figure 2.6. Effect of chart speed on the shapes of mass-loss curves. (I) Low chart speed (11) high chart speed (6). Figure 2.6. Effect of chart speed on the shapes of mass-loss curves. (I) Low chart speed (11) high chart speed (6).
A is the area under the force-elongation curve in cm S is the full-scale load in gf R is the cross-head speed in cm/min G is the (corrected) effective specimen length in cm IV is the chart width in cm L is the chart speed in cm/min... [Pg.465]

Effect of Detector Attenuation Change and Chart Speed on Peak Height,... [Pg.991]

A Perkin-Elmer Vapor Fractometer, Model 154, was used to separate the lead alkyls. The column used to effect the separation was a short 1-foot by J-inch column packed with 40% Nujol on 35-80 mesh Chromosorb. The helium flow rate was 100 cc per minute and a chart speed of g-inch per minute was used. The short column and a low temperature (70°C) were used to minimize possible decomposition of the organolead compounds. [Pg.362]

Use the method described above for the reduction by hydrazine, replacing hydrazine solution by 20.0 cm of H2O2 solution, prepared by 4-fold dilution of 20-volume H2O2. Check the chart speed compatible with die faster gas evolution in this case. Repeat using different samples and choose one sample of battery-active dioxide and prepared doped powders and study the effect of doping on the kinetics. [Pg.180]

Figure 4. Effect of the extract (BTJ, 42 mg i.v.) on tibialis anterior muscle (TIB), electrocardiogram (EKG), and arterial blood pressure (BP) in a 325 g anesthetized rat. The records were made at different chart speeds, as indicated by the time base. The inset just below the EKG trace shows details of the onset of the arrhythmia during the early stages of extract infusion. Figure 4. Effect of the extract (BTJ, 42 mg i.v.) on tibialis anterior muscle (TIB), electrocardiogram (EKG), and arterial blood pressure (BP) in a 325 g anesthetized rat. The records were made at different chart speeds, as indicated by the time base. The inset just below the EKG trace shows details of the onset of the arrhythmia during the early stages of extract infusion.
Figure 13-6C. Effects of pulsation filter on orifice flow meter charts at 300 rpm compressor speed. (A) Before peak-to-peak differential pulsations were 160 psi, and (B) after installation of filter pulsation, levels dropped to 1.5 psi. (Used by permission von Nimitz, W. W., and O. Flanigan, Oil and Gas Journal, p. 60, Sept. 8, 1980. PennWell Publishing Company. All rights reserved.)... Figure 13-6C. Effects of pulsation filter on orifice flow meter charts at 300 rpm compressor speed. (A) Before peak-to-peak differential pulsations were 160 psi, and (B) after installation of filter pulsation, levels dropped to 1.5 psi. (Used by permission von Nimitz, W. W., and O. Flanigan, Oil and Gas Journal, p. 60, Sept. 8, 1980. PennWell Publishing Company. All rights reserved.)...
Fig. 26 Effect of quenching speed on the morphology that develops [16]. a Time-temperature chart recorded in the sample spot, b Sequence showing morphological development when a PET melt is quenched moderately (see dotted line in a). Scale bar represents 50 pan. c Sequence showing morphological development after a PET melt is quenched rapidly to Tx = 130 °C (see solid line in a). Scale bar represents 20 xm... Fig. 26 Effect of quenching speed on the morphology that develops [16]. a Time-temperature chart recorded in the sample spot, b Sequence showing morphological development when a PET melt is quenched moderately (see dotted line in a). Scale bar represents 50 pan. c Sequence showing morphological development after a PET melt is quenched rapidly to Tx = 130 °C (see solid line in a). Scale bar represents 20 xm...
FIGURE 5 Chart plotting the results of a peak area precision study showing the effect of sample dosing speed, bubbles in flush solvent and air-tight vial closure. Reprint from Reference 18 with permission from American Chemical Society. [Pg.267]

Both the heat and mass transfer coefficients are functions of air velocity. However, at air speeds greater than about 15 ft/s (4.5 m/s), the ratio h kgis approximately constant. The wet-bulb depression is directly proportional to the difference between the humidity at the surface and the humidity in the bulk of the air. In the wet- and dry-bulb hygrometer, the wet-bulb depression is measured by two thermometers, one of which is fitted with a fabric sleeve wetted with water. These thermometers are mounted side by side and shielded from radiation, an effect neglected in the derivation above. Air is drawn over the thermometers by means of a small fan. The derivation of the humidity from the wet-bulb depression and a psychrometric chart are discussed later. [Pg.3884]

The Pareto chart for gloss is shown in Figure 5. The largest effect was mold temperature. Barrel temperature was next followed by injection speed, pack pressure and screw speed (SCREWS). [Pg.154]


See other pages where Chart speed, effect is mentioned: [Pg.125]    [Pg.231]    [Pg.55]    [Pg.218]    [Pg.11]    [Pg.11]    [Pg.465]    [Pg.661]    [Pg.21]    [Pg.697]    [Pg.190]    [Pg.29]    [Pg.35]    [Pg.1590]    [Pg.247]    [Pg.193]    [Pg.1126]    [Pg.1165]    [Pg.303]    [Pg.148]    [Pg.51]    [Pg.1563]    [Pg.2114]   
See also in sourсe #XX -- [ Pg.991 ]




SEARCH



Chart speed

Effective speed

© 2024 chempedia.info