Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Centrifugal maxima

More precise formulae appear to be necessary only if the anharmonicity effects of the molecule at high excitations are better known. Also, the exact interfragment potential and the corresponding centrifugal maxima have to be available to determine better rotational factors equations (24) and (25) have been based on an interfragment potential at the distances important for centrifugal maxima of the form V(g) oIl - 2( ,/ ) ], which corresponds to only the attractive part of a Lennard-Jones potential). [Pg.191]

These estimates bracket the NASA-JPL and lUPAC recommendations of 6.5x10 and 7.7 x 10 cm molecule s [9,60]. It is therefore possible fo reconcile fhe thermochemistry proposed here with the observed lO + NO2 recombination kinetics while employing reasonable input parameters for the unimolecular model. Nevertheless it must be stressed, as emphasized earlier [16], that there is considerable uncertainty in some of the input parameters to an RRKM analysis, especially the Frot term. It is of interest to compare the present kinetic calculations with the Multiwell [61] Master Equation calculations on this system by Golden [16]. He used a Morse potential to locate the centrifugal maximum, and from the bond extension Frot 2.1 is derived, about 1/7 of fhaf used here. On the other hand, the higher Eo value yields a density of sfafes larger by a facfor of 6, and fhese two factors largely cancel. [Pg.173]

Recover the RNA by centrifugation (maximum speed in a microcentrifuge at 4 C for 10 min). Decant the supernatant and resuspend the RNA in 400 pL of guanidinium thiocyanate solution. Transfer to a new microcentrifuge tube. [Pg.44]

The pressure-volume curve of a proposed centrifugal fan has a different shape. This fan curve must be drawn for the anticipated fan inlet density expected at its location in the system. The point of intersection of these two curves locates the flow rate and pressure rise at which the fan and system operate. This intersection represents a desirable operating combination for fan and system. The system curve intersects the fan curve in the middle of its maximum efficiency range and also at a point where the fan pressure produced varies smoothly but distinctly in a constant trend with flow rate which is desirable for flow control. [Pg.106]

The plough cannot be allowed to reach too close to the cloth and some residual cake remains. Where this is not acceptable, the cake may be removed by a pneumatic system, by vacuum, or by reslurrying. The cycle can be automated and controlled by timers. The maximum speeds of basket centrifuges vary from 800 to 1500 rpm, and basket diameters are in the range from 10 to 1400 mm. A 1200-mm diameter, 750-mm long basket may handle as much as 200 kg of cake in one charge. [Pg.413]

Booster Pump. Use of a centrifugal booster pump avoids a low intake pressure, particularly for large, high volume units. A low pressure (>26.6 kPa (200 mm Hg)) on the iatake of a timing pump can cause vaporization of the product. The booster pump is ia the circuit ahead of the timing pump and operates only when the FDV is ia forward flow, the metering pump is ia operation, and the pasteurized product is at least 7 kPa (1 psi) above the maximum pressure developed by the booster pump (Fig. 8). [Pg.358]

Sediment Volume. If the dispersion is unstable, the sediment bed will be quite deep and sedimenting particles will stick together where they first strike the sediment bed, thus forming an open stmcture with considerable occluded Hquid. If the dispersion is stable to reagglomeration, the particles will move freely past one another to avoid contact as long as possible. The result is a thin sediment bed with maximum soHds packing and minimum occluded hquid (12). Since dispersed particles setde more slowly than docs, centrifugation maybe needed to force sedimentation of small particles within a reasonable analysis time. [Pg.549]

Following carbonation, the product can be further purified by screening. This screening, also used to control the maximum size of the product, is followed by dewatering (qv). Rotary vacuum filters, pressure filters, or centrifuges are used in the mechanical removal of water. Final drying is accompHshed as with natural calcium carbonate in either a rotary, spray, or flash dryer. Products having mean particle sizes from submicrometers (- O-OS fiTo) to several micrometers are available. [Pg.411]

The pressure and the density of a gas are related by an equation of state. If the maximum pressure permitted within the centrifuge bowl is not too high, the equation of state for an ideal gas will suffice. The relationship between the pressure and density of an ideal gas is given by the weU-known equation ... [Pg.91]

Maximum Separative Capaeity and the Separative Effieieney. The separative efficiency of a gas centrifuge used for isotope separation is best defined in terms of separative work. Thus, the separative efficiency E is defined by... [Pg.93]

The Optimum Velocity Profile. The optimum velocity profile (41), that is the velocity profile that yields the maximum value for the flow pattern efficiency, is one in which the mass velocitypv is constant over the radius of the centrifuge except for a discontinuity at the wall of the centrifuge (r = rP). This optimum velocity profile is shown in Figure 14a. For this case the following values for the separation parameters of the centrifuge are obtained... [Pg.94]

These simple velocity profiles do not indicate directly any dependence of the flow pattern efficiency upon the rotational speed of the centrifuge. A dependence on speed is to be expected on the basis of the argument that at high speeds the gas in the centrifuge is crowded toward the periphery of the rotor and that the effective distance between the countercurrent streams is thereby reduced. It can be seen from the two-sheU model that, as the position of upflowing stream approaches the periphery, the flow pattern efficiency drops off from its maximum value. [Pg.95]

The separation parameters have been calculated for a centrifuge in which the behavior of the circulating gas is described by Martin s equation. The flow pattern efficiency is shown in Figure 15(b) as a function of the dimensionless parameter M, where M is equal to (ME /2RT). In this case the maximum flow pattern efficiency attainable is 0.956. [Pg.96]

Whereas the total dynamic head developed by a centrifugal, mixed-flow, or axial-flow pump is uniquely determined for any given flow by the speed at whicdi it rotates, positive-displacement pumps and those which approach positive displacement will ideally produce whatever head is impressed upon them by the system restrictions to flow. Actually with slippage neglecTed, the maximum head attainable is determined by the power available in the drive and the strength of the pump parts. An automatic relief valve set to open at a safe pressure... [Pg.909]

The performance of a centrifugal compressor (discharge to suction-pressure ratio vs. the flow rate) for different speeds is shown in Fig. 11-87. Lines of constant efficiencies show the maximum efficiency. Unstable operation sequence, called surging, occurs when compressors fails to operate in the range left of the surge envelope. It is characterized by noise and wide fluctuations of load on the compressor and the motor. The period of the cycle is usually 2 to 5 s, depending upon the size of the installation. [Pg.1113]

The two principal elements of evaporator control are evaporation rate a.ndproduct concentration. Evaporation rate in single- and multiple-effect evaporators is usually achieved by steam-flow control. Conventional-control instrumentation is used (see Sec. 22), with the added precaution that pressure drop across meter and control valve, which reduces temperature difference available for heat transfer, not be excessive when maximum capacity is desired. Capacity control of thermocompression evaporators depends on the type of compressor positive-displacement compressors can utilize speed control or variations in operating pressure level. Centrifugal machines normally utihze adjustable inlet-guide vanes. Steam jets may have an adjustable spindle in the high-pressure orifice or be arranged as multiple jets that can individually be cut out of the system. [Pg.1148]

General Characteristics Countercurrent flow is maintained by virtue of the difference in densities of the hquids and either the force of gravity (vertical towers) or centrifugal force (centrifugal extractors). Only one of the liquids may be pumped through the equipment at any desired velocity. Tne maximum velocity for the second is then fixed if it is attempted to exceed this limit, the second hquid will be rejected and the extractor will be flooded. [Pg.1473]


See other pages where Centrifugal maxima is mentioned: [Pg.172]    [Pg.5]    [Pg.171]    [Pg.558]    [Pg.566]    [Pg.28]    [Pg.161]    [Pg.408]    [Pg.14]    [Pg.109]    [Pg.152]    [Pg.404]    [Pg.64]    [Pg.233]    [Pg.404]    [Pg.404]    [Pg.406]    [Pg.411]    [Pg.411]    [Pg.413]    [Pg.414]    [Pg.415]    [Pg.415]    [Pg.90]    [Pg.90]    [Pg.93]    [Pg.93]    [Pg.94]    [Pg.96]    [Pg.440]    [Pg.767]    [Pg.926]    [Pg.1428]    [Pg.1726]    [Pg.1727]   
See also in sourсe #XX -- [ Pg.171 , Pg.172 ]




SEARCH



Centrifuge maximum allowable flow rate

Maximum separative power centrifuge

© 2024 chempedia.info