Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Capable faults

Guerrieri L, Blumetti AM, Esposito E, Michetti AM, Porfido S, Serva L, Tondi E, Vittori E (2008) Capable faulting, environmental effects and seismic landscape in the area affected by the 1997 Umbria-Marche (Central Italy) seismic sequence. Tectonophysics 476(l-2) 269-281... [Pg.1236]

Tsunami deposits are highly variable in extent, sediments, and preservation through time. If tsunami deposits are used as paleoseismic indicators, other source mechanisms like mass wasting or volcanic eruption have to be ruled out. Also, in high seismic areas with more than one capable fault, it is difficult to assign tsunami generation to an individual fault rather than to an area. [Pg.3794]

Field investigation on the SRS site must be continued as part of the effort to further confirm that the Pen Branch Fault is not a capable fault. [Pg.175]

Describe the geologic and tev tonic characteristics of the site, including a discussion of capable faults located within 200 miles of the site. [Pg.201]

Material of construction of sensor not suited for operating environment. Loss of sensing capability, leading to unwanted consequences such as spurious trips, overt (announced) and covert (unannounced) faults. [Pg.115]

The terminal box must be capable of withstanding the system fault current for at least 0.25 second. [Pg.188]

It is necessary to coordinate the HRC fuses with the overcurrent relay to ensure that during a fault the relay is capable of withstanding the let-through energy of the fuses without damage (Figures 12.11 and 12.15). [Pg.313]

We have mentioned two systems, I second and 3 second. A choice of any of them would depend upon the location and the application of the equipment and criticality of the installation. Generally speaking, it is only the one-second system that is in practice. The three-second system may sometimes be used for low fault level networks, where V3 / c, would fall within the capability of the available interrupting devices and at reasonable cost. [Pg.357]

The rated momentary peak value of the fault current, /y, will relate to the dynamic rating of an equipment. It is also known as the making current of a switching device and defines its capability to make on fault. [Pg.357]

As the moving contact moves away, so the arc plasma elongates, losing its initial intensity, and as it approaches the current zero, it loses the most of it. The gas, on the other hand, cools and regains its lost mass, while its pressure in the chamber continues to build to its optimum level, making it more capable of extinguishing a less severe arc plasma. The interrupter can thus be adjusted to blow out the arc at the first current zero, while clearing heavy to very heavy fault currents. [Pg.641]

A CT is provided in series with the spark gap to sense its operation during a line fault. As soon as there is arcing, it provides an instantaneous command to a short-circuit relay. The relay, in turn, closes the bypass breaker, within 3 to 5 cycles, leaving only the natural line impedance in the faulty eircuit. Now = 0, which limits the fault current to the natural level of the system, as if the capacitors were not connected. The shorting device is restored to its original status as soon as the fault condition is cleared. The device must be capable of interrupting the line fault... [Pg.836]

In the special case when d = 1 and of = 1, that is, when if a fault occurs it will not be detected and that failure is certain, occurrence equates directly to the probability of a fault. The probability of a fault in turn depends on the capability of the process used for the component/characteristic. [Pg.67]

A standard for the minimum acceptable process capability index for any component/characteristic is normally set at = 1.33, and this standard will be used later to align costs of failure estimates. If the characteristics follow a Normal distribution, Cp = 1.33 corresponds to a fault probability of ... [Pg.68]

PSAPACK 4,2 is an integrated fault/event tree package with capabilities for easily examining results and performing recalculations. There are two levels of processing in the package ... [Pg.141]

FTA, fault free analyzer module, uses SETS and FTAP to reduce fault trees and generate minimal cutsets for storage as minimal cutset libraries. Cutset control uses truncation hy probability or order. The user chooses the codes according to the personal computer s capabilities. The FTA module uses OR, AND, N/M, switch gates and supercomponents. [Pg.142]

Unlike products, nonconforming services are usually rendered unavailable for use by notices such as Out of Order or by announcements such as Normal service will be resumed as soon as possible . Products are often capable of operation with nonconformities whereas services tend to be withdrawn once the nonconformity has been detected, however trivial the fault. [Pg.437]

The use of event trees is sometimes limiting for liazard analysis because it may lack die capability of quantifying die potendal of die event occurring. Tlie analysis may also be incomplete if all inidal occurrences are not identified. Its use is beneficial in examining, rather dian evaluating, die possibilities and consequences of a failure. For this reason, a fault tree analysis (FTA) should supplement diis, to establish die probabilities of die event tree branches. Tliis topic was introduced in a subsection of Cliapter 16. [Pg.506]

Distribution voltage switchgear is designed for the range of full-load current and fault-current capabilities shown in Table 16.3. [Pg.213]

The grounding conductors must be capable of carrying maximum earth fault current without overheating or causing mechanical damage. [Pg.227]

The earth electrode system must be designed to be capable of carrying without damage to the full earth fault current of the supply system. [Pg.227]


See other pages where Capable faults is mentioned: [Pg.27]    [Pg.215]    [Pg.174]    [Pg.201]    [Pg.27]    [Pg.215]    [Pg.174]    [Pg.201]    [Pg.1701]    [Pg.2277]    [Pg.328]    [Pg.339]    [Pg.111]    [Pg.184]    [Pg.290]    [Pg.290]    [Pg.318]    [Pg.803]    [Pg.814]    [Pg.270]    [Pg.270]    [Pg.67]    [Pg.126]    [Pg.166]    [Pg.518]    [Pg.63]    [Pg.274]    [Pg.432]    [Pg.191]    [Pg.212]    [Pg.212]    [Pg.213]    [Pg.508]   
See also in sourсe #XX -- [ Pg.27 ]




SEARCH



© 2024 chempedia.info