Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Calibration ring

Can the calibration ring be identified How does the appearance of the calibration ring differ from that of diffraction maxima of the polymer ... [Pg.182]

The program, AXIS, was specifically designed to analyse fibre diffraction patterns similar to that shown in Figure 1, although some of the methods described in this chapter may be extended to other types of pattern if required. The fibre patterns are recorded on flat film using pinhole collimated, nickel-filtered CuKor radiation, and finely powdered calcite is dusted onto the specimen to provide a calibration ring of spacing 0.3035 nm. [Pg.113]

Before d-spacings or intensities may be measured, it is necessary to know the position of the centre of the pattern and the specimen-to-film distance. Both these parameters may be determined accurately by making use of the calibration ring (see Figure 1). [Pg.117]

While barrel, die, and water-bath temperatures and extrusion rate can be varied in pipe extrusion, the primary controls are the die gap, calibration rings or extended mandrel, and the take-off speed. Die gap and centering of the mandrel provide the initial wall thickness and thickness uniformity, whereas take-off speed determines the final thickness. While extended mandrels fix the inner diameter, calibration rings establish the outer diameter in vacuum and pressure cahbration systems. The other diameter varies with the take-off rate. Water-bath temperatures and temperature profiles control the cooling rate for the pipe or tubing. This alters the shrinkage, crystallinity, and retained stresses in the products. [Pg.386]

Remote Diaphragm Seals Isolation valves and calibration rings should be provided for on-line testing. Consider elevation relative to tap(s) and specific gravity of fill fluid of capillary in validating the calibration. [Pg.67]

It is important to note that simulated distillation does not always separate hydrocarbons in the order of their boiling point. For example, high-boihng multiple-ring-type compounds may be eluted earher than normal paraffins (used as the calibration standard) of the same boiling point. Gas chromatography is also used in the ASTM D 2427 test method to determine quantitatively ethane through pentane hydrocarbons. [Pg.1326]

Enzyme Reference Serums. Several companies sell lyophilized or stabilized reference serums for the calibration of instruments and for quality control. The label values given for the enzymatic activity of these serums should never be taken at face value, as at times they may be quite erroneous (19,33). Also, these values should only be used for the assay with which they were standardized, as interconversion of activity from one method to another for the same enzyme may often lead to marked errors. For instance, it is not recommended that alkaline phosphatase expressed in Bodansky units be multiplied by a factor to convert it to the units of the Ring-Armstrong method, or any other method for that matter. [Pg.190]

An example of a simulated overnight experiment on Mars is shown in Fig. 3.22 for eight temperature intervals using the Compositional Calibration Target (CCT made out of magnetite rock slab) on the rover as the target. In the case of contact-ring temperature sensor failure, the internal temperature sensor would be used (software selectable). [Pg.62]

Case, D. A. 1995. Calibration of Ring-Current Effects in Proteins and Nucleic Acids. Journal of Biomolecular NMR 6, 341. [Pg.123]

A fundamental assumption made for most dating with atmospheric radionuclides is that the cosmic radiation flux and hence, the natural production of the radionuclides has been constant with time. Various studies of this problem using 14C and tree-ring calibration have been made. Isotopic studies of meteorites have also been useful [17]. Considering the probable lack of basic accuracy of dating water, the problem of changes in cosmic ray flux is not serious. [Pg.195]

Epstein and Yapp [4] state "it is obviously necessary to calibrate more specifically the relationship between 6(D) records in cellulose nitrate from tree-ring records and known climatic records. This can probably be done best by the analysis of tree rings from widely different, well-documented environments. Such data will allow the comparison of a large variety of trees and determine the versatility of using the isotopic method for climatic temperature determination". We concur with this statement as long as "from the same population" is inserted. [Pg.231]

It is necessary to calibrate the 14C time scale for greater dating accuracy. However, the second-order variations are at least as important as the first-order constancy of atmospheric 14C. For example, they provide a record of prehistoric solar variations, changes in the Earth s dipole moment and an insight into the fate of C02 from fossil fuel combustion. Improved techniques are needed that will enable the precise measurement of small cellulose samples from single tree rings. The tandem accelerator mass spectrometer (TAMS) may fill this need. [Pg.234]

Radiocarbon years are calibrated from determinations of the 14C activity and stable isotopic carbon ratios of dendrochrono-logically dated tree rings [4]. The stable isotope data are required to normalize the dates to average wood with 613C value of -25 per mil (13C/12C fractionation relative to PDB reference standard). Photosynthetic and other plant physiological processes may produce differential isotopic fractionation between species, within the same species in different localities and even within the same tree under changing environmental conditions. [Pg.235]

Watmough, S.A., Hutchinson, T. C., and Evans, R. D. (1998). Development of solid calibration standards for trace elemental analyses of tree rings by laser ablation inductively coupled plasma-mass spectrometry. Environmental Science and Technology 32 2185-2190. [Pg.388]


See other pages where Calibration ring is mentioned: [Pg.176]    [Pg.176]    [Pg.117]    [Pg.117]    [Pg.120]    [Pg.120]    [Pg.121]    [Pg.136]    [Pg.137]    [Pg.384]    [Pg.176]    [Pg.176]    [Pg.117]    [Pg.117]    [Pg.120]    [Pg.120]    [Pg.121]    [Pg.136]    [Pg.137]    [Pg.384]    [Pg.287]    [Pg.287]    [Pg.1383]    [Pg.73]    [Pg.82]    [Pg.382]    [Pg.11]    [Pg.8]    [Pg.625]    [Pg.207]    [Pg.208]    [Pg.197]    [Pg.201]    [Pg.311]    [Pg.312]    [Pg.225]    [Pg.227]    [Pg.232]    [Pg.260]    [Pg.285]    [Pg.191]    [Pg.604]    [Pg.450]    [Pg.288]    [Pg.209]   
See also in sourсe #XX -- [ Pg.117 , Pg.118 , Pg.119 , Pg.120 ]




SEARCH



Calibration ring determining

Calibration ring radius

Radius of the calibration ring

© 2024 chempedia.info