Calibration ring determining

Radiocarbon years are calibrated from determinations of the 14C activity and stable isotopic carbon ratios of dendrochrono-logically dated tree rings [4]. The stable isotope data are required to normalize the dates to average wood with 613C value of -25 per mil (13C/12C fractionation relative to PDB reference standard). Photosynthetic and other plant physiological processes may produce differential isotopic fractionation between species, within the same species in different localities and even within the same tree under changing environmental conditions. [Pg.235]

Before d-spacings or intensities may be measured, it is necessary to know the position of the centre of the pattern and the specimen-to-film distance. Both these parameters may be determined accurately by making use of the calibration ring (see Figure 1). [Pg.117]

The RRDE is calibrated by determining its collection efficiency N. This parameter is defined as the fraction of a species formed at the disc that arrives at the ring and reacts there. To do this, consider a simple oxidation reaction, say, Fe to Fe. The disc potential is set at a positive value, where the oxidation process occurs at some rate i, while the ring potential is set at a very negative value, at which the oxidized species is reduced at its limiting current density. Assuming that there is initially no Fe in solution, the ring current results... [Pg.370]

While barrel, die, and water-bath temperatures and extrusion rate can be varied in pipe extrusion, the primary controls are the die gap, calibration rings or extended mandrel, and the take-off speed. Die gap and centering of the mandrel provide the initial wall thickness and thickness uniformity, whereas take-off speed determines the final thickness. While extended mandrels fix the inner diameter, calibration rings establish the outer diameter in vacuum and pressure cahbration systems. The other diameter varies with the take-off rate. Water-bath temperatures and temperature profiles control the cooling rate for the pipe or tubing. This alters the shrinkage, crystallinity, and retained stresses in the products. [Pg.386]

It is important to note that simulated distillation does not always separate hydrocarbons in the order of their boiling point. For example, high-boihng multiple-ring-type compounds may be eluted earher than normal paraffins (used as the calibration standard) of the same boiling point. Gas chromatography is also used in the ASTM D 2427 test method to determine quantitatively ethane through pentane hydrocarbons. [Pg.1326]

Epstein and Yapp [4] state "it is obviously necessary to calibrate more specifically the relationship between 6(D) records in cellulose nitrate from tree-ring records and known climatic records. This can probably be done best by the analysis of tree rings from widely different, well-documented environments. Such data will allow the comparison of a large variety of trees and determine the versatility of using the isotopic method for climatic temperature determination". We concur with this statement as long as "from the same population" is inserted. [Pg.231]

Fig. 2. Determination of the NOE across the glycosidic bond to estimate the distance between the two protons neighboring the glycosidic bond. The distances of the irradiated proton to others within the same ring serve as calibrations for the interglycosidic NOE... Fig. 2. Determination of the NOE across the glycosidic bond to estimate the distance between the two protons neighboring the glycosidic bond. The distances of the irradiated proton to others within the same ring serve as calibrations for the interglycosidic NOE...
The relationship between the disk current (iD) and the ring current (iR) depends on the rate of movement (velocity) of the product species from the disk to the ring electrode. However, only a fraction of the disk-electrode products will reach the ring-electrode surface. Thus, each ring-disk electrode must be calibrated with a well-behaved reversible couple to determine its collection efficiency (N) ... [Pg.80]

Apparatus Ring-and-ball softening point may be determined manually using the apparatus described below. Automated apparatus may be used provided equivalent results are obtained. The calibration of any automated apparatus should be monitored on a regular basis because accurate temperature control is required. The apparatus illustrated in Figs. 40 and 41 consists of the components described in the following paragraphs. [Pg.948]

The rate of the ring-opening reaction of 5, " and other substrates have been determined using an indirect method for the calibration of fast radical reactions, applicable for radicals with lifetimes as short as 1 ps/ This radical clock method is based on the use of Barton s use of pyridine-2-thione-Al-oxycarbonyl esters as radical precursors and radical trapping by the highly reactive thiophenol and benzeneselenol/ A number of radical clock substrates are known/ Other radical clock processes include racemization of radicals with chiral conformations, one-carbon ring expansion in cyclopentanones, norcarane and sprro[2,5]octane, a-and p-thujone radical rearrangements, and cyclopropylcarbinyl radicals or... [Pg.946]


See other pages where Calibration ring determining is mentioned: [Pg.117]    [Pg.120]    [Pg.136]    [Pg.137]    [Pg.384]    [Pg.50]    [Pg.82]    [Pg.11]    [Pg.227]    [Pg.160]    [Pg.209]    [Pg.207]    [Pg.453]    [Pg.38]    [Pg.44]    [Pg.117]    [Pg.565]    [Pg.570]    [Pg.425]    [Pg.335]    [Pg.644]    [Pg.193]    [Pg.23]    [Pg.60]    [Pg.209]    [Pg.570]    [Pg.48]    [Pg.367]    [Pg.147]    [Pg.69]    [Pg.405]    [Pg.281]    [Pg.60]    [Pg.424]    [Pg.137]    [Pg.441]    [Pg.570]    [Pg.346]   
See also in sourсe #XX -- [ Pg.120 ]