Calibration force sensors

The parameters include the critical cracking energy G and the mode-I tensile toughness of the coating. For the dual layer and triple layer systems presented here, the parameters deduced from three experiments for each type of sample are presented in Tables 6 and 7. The strain values are measured to an accuracy of 0.02% following a prior calibration. The applied stress is known to be within 0.1%, from a force sensor and the distance between two cracks is the average of twenty or so values determined to an accuracy of one micron in the central part of the specimen. [Pg.71]

How, and in what direction sound energy is transferred and radiated outward from frictional sound somces is also not well imderstood. Researchers in the field of haptics (haptics describes the combined touch senses of tactile, kinesthetic, motion, force, etc.) use robots fixed with force sensors to measure the frictional profiles of various objects and interactions. Recently, Dinesh Pai and others have begim to add soimd analysis/synthesis to this work, simultaneously recording forces and soimds, and using the results to calibrate sound synthesis and force-feedback systems. [Pg.183]

When die surfaces arc in contact die motion of the piezoelectric tube is transmitted directly to die force sensor. This results in a linear increase of die force sensor signal with the expansion of die piezoelectric tube. The sensitivity of the force sensor can be calibrated from this straight line, and this measuring procedure allows determination of forces as a function of separation from a hard wall contact with a high precision (within 1-2 A in distance resolution). Note, however, that the assumption of a hard wad contact is not always correct (29). [Pg.312]

In applications where there is a definite need to know the absolute calibrated force (be it in pounds or tons), the first choice in sensor selection should be a strain-gauge-based device. In terms of the sensor location within the die, the first choice should be the stationary or lower part of the tooling. For progressive dies and multistation transfer tools, the preferred location for these precalibrated load cells is beneath the individual tool stations in pockets machined into the die shoe. [Pg.371]

In fact, two types of arrays of micro-force sensors would be developed. The first one is a basic version obtained by assembling existing micro-force sensors to produce a demonstrator system. To do it, the engineers start from specifications defined by the physicists but they start the design and realisation for internal reasons the opportunity to still work on 100 millimetres equipment before the technological platform moves towards new industrial standards. They expect to deliver five calibrated... [Pg.198]

Knowledge of the sample pressure is essential in all high-pressure experiments. It is vital for determinations of equations of state, for comparisons with other experimental studies and for comparisons with theoretical calculations. Unfortunately, one cannot determine the sample pressure directly from the applied force on the anvils and their cross-sectional area, as losses due to friction and elastic deformation cannot be accurately accounted for. While an absolute pressure scale can be obtained from the volume and compressibility, by integration of the bulk modulus [109], the most commonly-employed methods to determine pressures in crystallographic experiments are to use a luminescent pressure sensor, or the known equation of state of a calibrant placed into the sample chamber with the sample. W.B. Holzapfel has recently reviewed both fluorescence and calibrant data with the aim of realising a practical pressure scale to 300 GPa [138]. [Pg.78]

Fach new sensor array is automatically calibrated prior to the mea,suremeni step. A blood sample withdrawn from the patient is deposited into the sample entry well, and the cartridge is inserted inlo the i-STAT analyzer. The calibrant pouch, which contains a standard buffered solution of the analytes, is punctured hy the i-STAT analyzer and is compressed to force the calibrant through the flow channel across the surface of the sensor array. When the calibration step is complete, the analyzer compresses the air bladder, which forces the blood sample through the flow channel toe.s-... [Pg.682]

The responses in Fig. 3.8 are calibrated results by two methods of the sensor calibration. One is a calibration method by NIST, as illustrated in Fig. 3.10 (Breckenridge 1982). A large steel block of 90 cm diameter and 43 cm deep was employed. As a step-function impulse, a glass capillary source was employed, and elastic waves were detected by a capacitive transducer and by a sensor under test. The calibration curve was obtained as a ratio of the response of the sensor to that of the eapacitive transducer. The capacitive transducer (sensor) could record a Lamb s solution due to surface pulse as discussed in Chapter 7. It is reasonably assumed that the capacitive transducer detect the vertical displacement at the surface due to a step-function force. The other is known as a reciprocity method, which Hatano and Watanabe (Hatano Watanabe 1997) suggested to use, and confirmed an agreement with the NIST methods. As seen in Fig. 3.8, it is demonstrated that both method can provide similar calibration curves. [Pg.30]

We have chosen another type of Amberlite resin, polymeric adsorbent XAD 1168, as a support in order to investigate its influence on dissociation constant of the dye. An identical, as previously described, procedure of immobilization was applied and a saturated solution of BTB was used. In this case the dye-support binding forces were mainly based on physical sorption interactions. Figure 7 compares calibration curves of the pH sensors based on the membranes prepared from different Amberlite resins. [Pg.963]

The calibration curve of the calcium sensor is presented in figure 15. The lower limit of detection was found at about 10- mol/dm. The membrane exhibited linear dependence of the signal in function of the calcium ions concentration. However, at high concentrations (about 10 2 mol/dm ) the indicator started to be washed out from the membrane because of weak adsorption forces. [Pg.972]

In electronic balances the force exercised by the load on the base is measured with a force measurement cell (for example, an electrical strain gauge) and transformed into an electrical signal. This signal is processed within the balance in a digital or analog fashion and is then displayed. These systems can be calibrated and used in fully automatic installations. As force measurement cells one can use pressure sensors with lower requirements for accuracy. These are installations in which the weight is transformed into pressure pneumatically or hydraulically one can determine levels in tanks or reaction vessels by this method, which can also be used to meter automatically the main ingredients of a batch process, for example the water and monomer phase in an emulsion or suspension polymerization. [Pg.605]

Fig. 7 Force measurement with a ferroelectret sensor coupled to a charge amplifier top). A rectangular varying compressive force is applied to the sample. Force rate measurement, when the ferroelectret sensor is connected to a digital oscilloscope bottom). Measurement signals can be calibrated to determine the piezoelectric coefficient of the ferroelectret foam sensor... Fig. 7 Force measurement with a ferroelectret sensor coupled to a charge amplifier top). A rectangular varying compressive force is applied to the sample. Force rate measurement, when the ferroelectret sensor is connected to a digital oscilloscope bottom). Measurement signals can be calibrated to determine the piezoelectric coefficient of the ferroelectret foam sensor...
If the sensor bore does not correspond to the required tolerances, the sensor front touches the sensor bore in many cases, and the sensor loses its sensitivity. In technical language, this effect is called force shunt and can cause measurement errors of up to 30%. For this reason, cavity pressure sensors have recently developed that are initially built precisely into a sleeve and then calibrated in a second step [1]. The actual sensor is thus protected during installation, and measurement errors through the installation are excluded (PRIASAFE principle). The determined sensitivity is eventually stored in the sensor body itself as a code, so that no adjustments in the subsequent electronics in the industrial use have to be made [2]. The optimal measuring ranges are determined automatically as soon as the sensor is connected to the electronics (PRIASED principle). [Pg.648]

Atomic force microscopes may use sophisticated algorithms to modify the voltages applied to actuating elements (piezoelectric ceramics) that incorporate the effects of scan rate, scan size,non-linearities,andcross-talk.Thisapproach is referred to as an open loop method. Closed loop approaches are also available. These provide an independent method of dimensional measurement (strain gauges, capacitance sensors, or optical interferometers) in order to apply realtime correction to actuator motion. Closed loop is more readily applied in x and y dimensions recent advances include z motion. Closed loop calibration can introduce additional electric noise, and care is required to make sure that ultimate resolution is not compromised. [Pg.58]

Sensors, Calibration of. Fig. 3 Simplified principle behind the force balanced accelerometer. The displacement transducer normally uses a capacitor C, whose capacitance varies with the displacement of the mass. A current, proportional to the displacement transducer output, will force the mass to remain stationary relative to the frame (Figure from Havskov and Alguacil 2010)... [Pg.3258]

A signal generator sends out a sine wave with a constant amplitude Vq. This voltage is applied to the sensor calibration input and exerts a force on the mass proportional to Vq. For the velocity sensor with a calibration coil, the amplimde of the force/ will be... [Pg.3263]

Calibration Pulse It is common practice to generate a calibration pulse by applying a step current into the calibration coil of a passive sensor. For a BB sensor an equivalent test can be made when a voltage is applied to the feedback loop to produce a force on the mass. As the applied force is proportional to the coil current or the voltage, this input signal is equivalent to a ground step in acceleration (see also section above). The output pulse can be recorded (Fig. 9), and this pulse can be used in several ways to obtain sensor parameters. [Pg.3265]

Depending on the simulator, with suitable calibrated sensors (Figure 26.13), this force-control concept could therefore facilitate assessment of the dynamic performance of a TKR implant by measuring its kinematics in vitro during a simulated walking activity. [Pg.395]


See other pages where Calibration force sensors is mentioned: [Pg.371]    [Pg.372]    [Pg.417]    [Pg.16]    [Pg.386]    [Pg.667]    [Pg.958]    [Pg.595]    [Pg.24]    [Pg.184]    [Pg.613]    [Pg.148]    [Pg.198]    [Pg.291]    [Pg.279]    [Pg.320]    [Pg.48]    [Pg.89]    [Pg.348]    [Pg.370]    [Pg.28]    [Pg.335]    [Pg.66]    [Pg.25]    [Pg.995]    [Pg.4]    [Pg.629]    [Pg.148]    [Pg.753]    [Pg.3263]    [Pg.402]   