Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Boundary handling

S-13C How is an insulated boundary handled in the finite difference formulation of a problem How does a symmetry line differ from an insulated boundaty in the finite difference formulation ... [Pg.354]

Fig. 5 Boundary handling by periodisation (a) sample spectrum, (b). spectrum wraparound with period K and e.xtension to infinity. Fig. 5 Boundary handling by periodisation (a) sample spectrum, (b). spectrum wraparound with period K and e.xtension to infinity.
Fig. 13 Boundary handling using symmetric e.xtension by reflection. Fig. 13 Boundary handling using symmetric e.xtension by reflection.
Fig. 14 Boundary handling using exten.sion hy antisymmetric reflection. Fig. 14 Boundary handling using exten.sion hy antisymmetric reflection.
Fig. 15 WPT results for a linear ramp signal IN = 128, Dauhechies wavelet. N/ = 6) with boundary handling using. symmetric extension. First six levels shown only. Fig. 15 WPT results for a linear ramp signal IN = 128, Dauhechies wavelet. N/ = 6) with boundary handling using. symmetric extension. First six levels shown only.
Since singularities about the boundaries can be significant, boundary handling with constant-padding extension should be used with care. [Pg.114]

In the polynomial extension approach to boundary handling the data sequence is extrapolated by fitting a polynomial to the end-points of the se-... [Pg.114]

Boundary handling using wavelets on an interval The extension techniques for boundary handling so far investigated are quite useful, producing the desired effect - as long as the appropriate technique is used for the data set at hand. However, a more obvious approach is to directly construct the wavelet on the interval [0, K]. [Pg.116]

Beckman Elutriation Method. The Beckman elutriation method uses a chamber designed so that the centrifugal effect of the radial inward fluid flow is constant (Fig. 3). The separation chambers are made of transparent epoxy resin which faciUtates observation of the movements of the cell boundary in strobe light illumination. This enables detection of the radius at which the cells are separating. When a mixture of cells, eg, mononuclear white cells, enters the chamber, separation can be achieved by fine tuning centrifuge speed and inward fluid flow to the specific cell group. This is a laboratory method suitable for relatively small numbers of cells. Chambers are available in sizes to handle 2-3 x 10 , 1 2 x 10 , and 1 x 10 ° cells. The Beckman chambers can be appHed to collect mononuclear cells from bone marrow aspirates. [Pg.522]

In addition to the laws and regulations that govern the handling of the substances involved in the process, the parties have legal obligations to one another as stated in the contract. Contract topics that specify boundaries may include ... [Pg.51]

Exposure in a solution that is passivating and yet not far removed from the passive-activity boundary may lead to coiTosion if the exposure involves a strong abrasive condition as well. Pitting of pump shafts under packing handling sea water is an example of this abrasive effect. [Pg.259]

The results of the audits indicate that the delineation of zones is easy to put into a plan hut difficult to keep current. The nature of remedial work demands fiexihility. As sites become remediated, the exclusion zone boundaries change. This is not a situation that is easily handled in a plan, but should be reviewed as other site documents on a predetermined regular basis. [Pg.200]

The mathematical principles of convective heat transfer are complex and outside the scope of this section. The problems are often so complicated that theoretical handling is difficult, and full use is made of empirical correlation formulas. These formulas often use different variables depending on the research methods. Inaccuracy in defining material characteristics, experimental errors, and geometric deviations produce noticeable deviations between correlation formulas and practice. Near the validity boundaries of the equations, or in certain unfavorable cases, the errors can be excessive. [Pg.113]

Good entry of the air into the cupboard reduces the size of eddies at the boundaries and can be achieved by using rounded jambs at the side walls, an aerofoil on the sill, and a well designed sash handle. ... [Pg.885]

DATA BOUNDARY Solids handling equipment for one plant rotary kiln,... [Pg.54]


See other pages where Boundary handling is mentioned: [Pg.99]    [Pg.99]    [Pg.111]    [Pg.113]    [Pg.114]    [Pg.117]    [Pg.117]    [Pg.118]    [Pg.126]    [Pg.99]    [Pg.99]    [Pg.111]    [Pg.113]    [Pg.114]    [Pg.117]    [Pg.117]    [Pg.118]    [Pg.126]    [Pg.58]    [Pg.2242]    [Pg.2277]    [Pg.613]    [Pg.192]    [Pg.193]    [Pg.194]    [Pg.106]    [Pg.555]    [Pg.448]    [Pg.151]    [Pg.153]    [Pg.745]    [Pg.1410]    [Pg.191]    [Pg.226]    [Pg.435]    [Pg.199]    [Pg.892]    [Pg.711]    [Pg.616]    [Pg.517]    [Pg.48]    [Pg.304]   
See also in sourсe #XX -- [ Pg.99 , Pg.111 , Pg.113 , Pg.114 , Pg.116 , Pg.117 ]




SEARCH



Boundary Condition Handling

© 2024 chempedia.info