Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Baseline placement

The first source of uncertainty affecting these results is the placement of the experimental baseline on the oscilloscope photographs for each kinetic run. After minimizing the effects of random error in baseline placement, we screened computer fitted rates of individual kinetic determinations for outliers indicative of non-random electrical noise. An example is shown in Figure 3. Ue have plotted the logarithm of the exponential rate constants (a s) for ell the individual seawater experiments at pH s between 8 and 8.3 versus the logarithm of the second-order rate constants (B s) for the same runs. The entire data set, including four seawater types, yields a mean a of 2.54 . 79 X 1q3 s l and a mean 8 of 10.74 3.95 x 10 1 m l s. The three circled points are outliers sufficiently different from the rest to be rejected. [Pg.104]

Before ameroiid 30 days after ameroid 60 days after ameroid placement baseline) placemenl/before placement/30 days... [Pg.99]

Fig. 7.3 (A) Left ventricular ejection fraction at rest. Assessments were made at baseline before ameroid placement left), 30 days later at time of cell or saline injection middle), and 60 days after ameroid placement right). (B) Left ventricular ejection fraction with stress. Assessments were made before and 30 days after intramyocardial injection. Reprinted from [63]... Fig. 7.3 (A) Left ventricular ejection fraction at rest. Assessments were made at baseline before ameroid placement left), 30 days later at time of cell or saline injection middle), and 60 days after ameroid placement right). (B) Left ventricular ejection fraction with stress. Assessments were made before and 30 days after intramyocardial injection. Reprinted from [63]...
Pressure loops are used to control the pump delivery rate, by the placement of a sensitive and highly responsive pressure transducer downstream of the pump heads. Once a normalized baseline is established, the sensing circuitry regulates motor speed to keep the pressure constant. A momentary decrease in pressure will cause the control loop to accelerate the motor in order to increase the pressure. Although the pressure loop is effective at maintaining a smooth pressure delivery, it is done at the expense of flow accuracy. [Pg.77]

Baseline drift creates errors in a number of ways. It can affect the true area of the peak, the retention time of the peak, and the operating range of the detector. When a peak is eluted on a baseline slope, the baseline that is drawn under the peak is usually a straight line. The true baseline, however, may often be curved, as shown in Figure 7.16 thus, area may be lost or gained by incorrect placement of the baseline. [Pg.230]

Figure 7.16 Errors associated with incorrect placement of baseline. The dotted line represents the true baseline the dashed baseline is the one placed by the integrator. The left-hand side shows area lost by incorrect placement of the baseline the right-hand side shows area gained by incorrect placement of the baseline. (Reprinted from Ref. 11 with permission.)... Figure 7.16 Errors associated with incorrect placement of baseline. The dotted line represents the true baseline the dashed baseline is the one placed by the integrator. The left-hand side shows area lost by incorrect placement of the baseline the right-hand side shows area gained by incorrect placement of the baseline. (Reprinted from Ref. 11 with permission.)...
The perpendicular drop should only be used if (1) the peaks are symmetrical and about the same height and width, (2) the valley between the peaks is no more than 5% of the peak height, (3) the baseline is flat, and (4) noise does not obscure the accurate placement of the baseline. If the peaks are asymmetrical, a perpendicular drop will overestimate the area of the smaller peak. Under those circumstances, a tangential skim may be a better approach. [Pg.231]

Initial assessment of the CXR evaluates the quality of the film for patient rotation, inspiratory effort, and penetration. Rotation is assessed by evaluating symmetry of the clavicles and central placement of the Carina. Inspiratory effect is considered adequate if the diaphragms are pulled below the ninth rib. Lack of inspiratory effort and obesity lead to a poor-quality CXR, which makes it more difficult to assess the presence of pleural effusions and fluid in the costophrenic angles. Where possible, comparison with previous or baseline films is done to determine the quality of film and comparison of structures. [Pg.153]

The AMADEUS registry is a prospective multicenter European registry to evaluate the safety and efficacy of the CARILLON Mitral Contour System in patients with function mitral regurgitation. Joachim Schofer recently presented 6-month clinical outcomes of 48 patients (34). Among the 30 patients with successful device placement, cardiac perforation was noted in three patients at one month and there were two deaths (6.9%) and three myocardial infarctions reported at six months. The regurgitant volume was reduced from 35 16 mL at baseline to 24 12 at six months (P <0.001) and six-minute walk test increased from a mean of 307 meters to 403 meters (P <0.001). [Pg.130]

Another major nonprocess waste stream is used personal protective clothing and equipment, which includes DPE suits, Tyvek coveralls, gloves, boots, masks, canisters, filters, hoses, and other items. The disposal method for this type of waste depends on whether it is at a 3X decontamination level or has never been in contact with agent. The current baseline method is to retain this waste for placement in a hazardous waste landfill as a listed waste. Parsons/Honeywell proposes to process DPE suits and other personal protective wastes through the CST after size reduction to improve homogeneity... [Pg.77]

A fairly common practice in a pre-placement medical examination program, in addition to a thorough physical and a battery of tests, is to take a serum sample to be stored in an ultra-low temperature freezer. These samples take up very little space and are valuable should a question later arise where a comparison between a current serum specimen and a baseline sample would be useful. It is also possible and feasible to lyophilize the serum for storage. This might be cost effective and space saving if a large number of specimens are to be kept. [Pg.391]

Empirical Results. In Table 9.2 we compare the Perseus baseline to the following additions (i) only Mercury, (ii) only force-directed placement (FDP), and (iii) only gradual evolution of clock networks. In these designs we compare circuit performance metrics including the worst slack path in the design, and 4>, the sum of slacks below a threshold, which is computed as follows considering every timing endpoint i ... [Pg.145]

The challenge for spinal artery CTA is to provide sufficient arterial enhancement but to scan before arrival of contrast medium in the venous system. An ROI of the bolus tracking system placed in the ascending aorta might be affected by inflow artifacts of the SVC and may result in a mistimed early scan. Therefore, placement of the ROI in the aortic arch or descending aorta is recommended. In the presence of aortic dissection, caution should be taken that the ROI is not too big or positioned in the false lumen or across the dissection membrane, respectively. In these cases, manual start of the scan should be considered. The Hounsfield unit threshold should be around 100 HU above baseline. Scan start is usually delayed by time for table movement (<3 s), which is usually right above the origin of the vertebral arteries. An additional scan delay of 3 s is recommended for scanners with equal to or more than 16 rows and rotation time equal or less than 0.4 s. Hounsfield unit values of attenuated blood in the thoracic aorta should never be lower than within the pulmonary trunk. [Pg.315]


See other pages where Baseline placement is mentioned: [Pg.600]    [Pg.68]    [Pg.104]    [Pg.31]    [Pg.600]    [Pg.68]    [Pg.104]    [Pg.31]    [Pg.201]    [Pg.249]    [Pg.399]    [Pg.79]    [Pg.181]    [Pg.185]    [Pg.172]    [Pg.79]    [Pg.133]    [Pg.231]    [Pg.356]    [Pg.136]    [Pg.961]    [Pg.170]    [Pg.390]    [Pg.3342]    [Pg.30]    [Pg.366]    [Pg.407]    [Pg.40]    [Pg.125]    [Pg.514]    [Pg.446]    [Pg.425]    [Pg.1188]    [Pg.122]    [Pg.352]    [Pg.158]    [Pg.118]    [Pg.29]    [Pg.135]    [Pg.425]   
See also in sourсe #XX -- [ Pg.231 ]




SEARCH



Baseline

Placement

© 2024 chempedia.info