Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Atomic optical spectrometry physical

Interferences are physical or chemical processes that cause the signal from the analyte in the sample to be higher or lower than the signal from an equivalent standard. Interferences can therefore cause positive or negative errors in quantitative analysis. There are two major classes of interferences in AAS, spectral interferences and nonspectral interferences. Nonspectral interferences are those that affect the formation of analyte free atoms. Nonspectral interferences include chemical interference, ionization interference, and solvent effects (or matrix interference). Spectral interferences cause the amount of light absorbed to be erroneously high due to absorption by a species other than the analyte atom. While all techniques suffer from interferences to some extent, AAS is much less prone to spectral interferences and nonspectral interferences than atomic anission spectrometry and X-ray fluorescence (XRF), the other major optical atomic spectroscopic techniques. [Pg.466]

The basic instrumentation used for spectrometric measurements has already been described in the previous chapter (p. 277). Methods of excitation, monochromators and detectors used in atomic emission and absorption techniques are included in Table 8.1. Sources of radiation physically separated from the sample are required for atomic absorption, atomic fluorescence and X-ray fluorescence spectrometry (cf. molecular absorption spectrometry), whereas in flame photometry, arc/spark and plasma emission techniques, the sample is excited directly by thermal means. Diffraction gratings or prism monochromators are used for dispersion in all the techniques including X-ray fluorescence where a single crystal of appropriate lattice dimensions acts as a grating. Atomic fluorescence spectra are sufficiently simple to allow the use of an interference filter in many instances. Photomultiplier detectors are used in every technique except X-ray fluorescence where proportional counting or scintillation devices are employed. Photographic recording of a complete spectrum facilitates qualitative analysis by optical emission spectrometry, but is now rarely used. [Pg.288]

Owing to the line broadening mechanisms, the physical widths of spectral lines in most radiation sources used in optical atomic spectrometry are between 1 and 20 pm. This applies both for atomic emission and atomic absorption line profiles. In reality the spectral bandwidth of dispersive spectrometers is much larger than the physical widths of the atomic spectral lines. [Pg.16]

For all the techniques of optical atomic spectrometry, the samples (solutions and/or solid samples) must be converted into an atomic vapour. The sensitivity is strongly dependent on the yield of this process, as are the chemical and physical interferences, i.e. the specificity of the method in general. For the first approach, the atomization of the sample is proportional and the occurrence of chemical and/or physical interferences is inversely proportional to the excitation temperature. Therefore the temperature available in the atomization stage should be as high as possible. The classical excitation sources used in atomic spectrometry like flame, graphite furnace, arc and spark are well known. The temperature available, especially in a flame or in the graphite furnace, is around 3000°C. Due to the Boltzmann-distribution... [Pg.92]

This article provides some general remarks on detection requirements for FIA and related techniques and outlines the basic features of the most commonly used detection principles, including optical methods (namely, ultraviolet (UV)-visible spectrophotometry, spectrofluorimetry, chemiluminescence (CL), infrared (IR) spectroscopy, and atomic absorption/emission spectrometry) and electrochemical techniques such as potentiometry, amperometry, voltammetry, and stripping analysis methods. Very few flowing stream applications involve other detection techniques. In this respect, measurement of physical properties such as the refractive index, surface tension, and optical rotation, as well as the a-, //-, or y-emission of radionuclides, should be underlined. Piezoelectric quartz crystal detectors, thermal lens spectroscopy, photoacoustic spectroscopy, surface-enhanced Raman spectroscopy, and conductometric detection have also been coupled to flow systems, with notable advantages in terms of automation, precision, and sampling rate in comparison with the manual counterparts. [Pg.1275]

Chemical analysis of polymers typically deals with monomers or functional groups rather than constituent atoms. Thermal infrared and laser optical Raman spectrometry are the typical tools (36) (see Test Methods Vibrational Spectroscopy), but frequently, specific specimen size or form is required. For physical properties, mechanical and sonic/ultrasonic NDT methods are available (see above). Molecular mass distribution and related properties of polymers, or fiber or particle volume fraction and distribution for PMC, are usually determined destructively (see Test Methods). [Pg.5081]

Atomic Spectrometry Aurora Galactic Structure and Evolution INERARED ASTRONOMY INTERSTELLAR MATTER Planetary Atmospheres Solar Physics Stellar Spectroscopy Stellar Structure AND Evolution telescopes. Optical... [Pg.327]


See other pages where Atomic optical spectrometry physical is mentioned: [Pg.443]    [Pg.434]    [Pg.324]    [Pg.434]    [Pg.1555]    [Pg.1558]    [Pg.64]    [Pg.326]    [Pg.516]    [Pg.267]    [Pg.169]    [Pg.313]    [Pg.11]    [Pg.8]    [Pg.457]    [Pg.224]    [Pg.146]    [Pg.146]    [Pg.216]    [Pg.328]    [Pg.19]    [Pg.9]    [Pg.317]    [Pg.1072]   


SEARCH



Atom optics

Atomic physics

Atoms physics

Optical spectrometry

Physical optics

© 2024 chempedia.info