Derivative spectroscopy provides a means for presenting spectral data in a potentially more useful form than the zero th order, normal data. The technique has been used for many years in many branches of analytical spectroscopy. Derivative spectra are usually obtained by differentiating the recorded signal with respect to wavelength as thf spectrum is scanned. Whereas early applications mainly relied on hard-wired units for electronic differentiation, modem derivative spectroscopy is normally accomplished computationally using mathematical functions. First-, second-, and higher-order derivatives can easily be generated. [Pg.55]

Vibrational spectroscopy is of utmost importance in many areas of chemical research and the application of electronic structure methods for the calculation of harmonic frequencies has been of great value for the interpretation of complex experimental spectra. Numerous unusual molecules have been identified by comparison of computed and observed frequencies. Another standard use of harmonic frequencies in first principles computations is the derivation of thermochemical and kinetic data by statistical thermodynamics for which the frequencies are an important ingredient (see, e. g., Hehre et al. 1986). The theoretical evaluation of harmonic vibrational frequencies is efficiently done in modem programs by evaluation of analytic second derivatives of the total energy with respect to cartesian coordinates (see, e. g., Johnson and Frisch, 1994, for the corresponding DFT implementation and Stratman etal., 1997, for further developments). Alternatively, if the second derivatives are not available analytically, they are obtained by numerical differentiation of analytic first derivatives (i. e., by evaluating gradient differences obtained after finite displacements of atomic coordinates). In the past two decades, most of these calculations have been carried... [Pg.146]

Luminescence spectroscopy is an analytical method derived from the emission of light by molecules which have become electronically excited subsequent to the absorption of visible or ultraviolet radiation. Due to its high analytical sensitivity (concentrations of luminescing analytes 1 X 10 9 moles/L are routinely determined), this technique is widely employed in the analysis of drugs and metabolites. These applications are derived from the relationships between analyte concentrations and luminescence intensities and are therefore similar in concept to most other physicochemical methods of analysis. Other features of luminescence spectral bands, such as position in the electromagnetic spectrum (wavelength or frequency), band form, emission lifetime, and excitation spectrum, are related to molecular structure and environment and therefore also have analytical value. [Pg.441]

In analytical chemistry derivative spectroscopy is frequently used if the... [Pg.273]

Many analytical applications of atomic spectroscopy produce their spectra by arc or spark excitation techniques and these methods form the basis for much of the present practice in the field. The historical development in this area is most difficult to document since almost from the start, after observations of the spectrum from the sun, the attempt was to utilize high-energy sources. This led immediately to arc and spark methods. The present-day applications of the arc or spark are improvements of the early work with attempts to better stabilize and control excitation conditions within the arc or spark in an effort to improve analytical data derived from the spectra. These techniques will be discussed in Chapter 5, which deals with accessory equipment for arc and spark spectrochemical analysis. [Pg.7]

Acetylene Derived from Hydrocarbons The analysis of purified hydrocarbon-derived acetylene is primarily concerned with the determination of other unsaturated hydrocarbons and iaert gases. Besides chemical analysis, physical analytical methods are employed such as gas chromatography, ir, uv, and mass spectroscopy. In iadustrial practice, gas chromatography is the most widely used tool for the analysis of acetylene. Satisfactory separation of acetylene from its impurities can be achieved usiag 50—80 mesh Porapak N programmed from 50—100°C at 4°C per minute. [Pg.378]

Abstract Protoberberine alkaloids and related compounds represent an important class of molecules and have attracted recent attention for their various pharmacological activities. This chapter deals with the physicochemical properties of several isoquinoline alkaloids (berberine, palmatine and coralyne) and many of their derivatives under various environmental conditions. The interaction of these compounds with polymorphic DNA structures (B-form, Z-form, H -form, protonated form, triple helical form and quadruplex form) and polymorphic RNA structures (A-form, protonated form, triple helical form and quadruplex form) reported by several research groups, employing various analytical techniques such as spectrophotometry, spectrofluorimetry, circular dichro-ism, NMR spectroscopy, viscometry as well as molecular modelling and thermodynamic analysis to elucidate their mode and mechanism of action for structure-activity relationships, are also presented. [Pg.156]

The most basic method for the determination of the methylxanthines is ultraviolet (UV) spectroscopy. In fact, many of the HPLC detectors that will be mentioned use spectroscopic methods of detection. The sample must be totally dissolved and particle-free prior to final analysis. Samples containing more than one component can necessitate the use of extensive clean-up procedures, ajudicious choice of wavelength, the use of derivative spectroscopy, or some other mathematical manipulation to arrive at a final analytical measurement. A recent book by Wilson has a chapter on the analysis of foods using UV spectroscopy and can be used as a suitable reference for those interested in learning more about this topic.1... [Pg.24]

Sections on matrix algebra, analytic geometry, experimental design, instrument and system calibration, noise, derivatives and their use in data analysis, linearity and nonlinearity are described. Collaborative laboratory studies, using ANOVA, testing for systematic error, ranking tests for collaborative studies, and efficient comparison of two analytical methods are included. Discussion on topics such as the limitations in analytical accuracy and brief introductions to the statistics of spectral searches and the chemometrics of imaging spectroscopy are included. [Pg.556]

In the list of diazoketones studied by us95 mostly derivatives were included which have in solution no or only a small tendency for a Wolff rearrangement. Nevertheless we found not a single diazoketone 71 which enabled us to identify a ketocarbene 72, only the corresponding ketenes 73 could be detected. The same observation was made when we studied in collaboration with Yannoni et al." the photochemically induced deazotation of l-diazo-2-propanone in an organic matrix at 77 K, using 13C CPMAS NMR spectroscopy as the analytical tool. [Pg.132]


See other pages where Analytical spectroscopy derivative is mentioned: [Pg.137]    [Pg.64]    [Pg.83]    [Pg.413]    [Pg.23]    [Pg.69]    [Pg.208]    [Pg.545]    [Pg.135]    [Pg.133]    [Pg.265]    [Pg.149]    [Pg.5]    [Pg.199]    [Pg.302]    [Pg.305]    [Pg.452]    [Pg.734]    [Pg.181]    [Pg.4]    [Pg.143]    [Pg.725]    [Pg.740]    [Pg.17]    [Pg.7]    [Pg.237]    [Pg.339]    [Pg.66]    [Pg.66]    [Pg.16]    [Pg.277]    [Pg.325]    [Pg.149]    [Pg.42]    [Pg.214]    [Pg.841]    [Pg.24]    [Pg.997]   
See also in sourсe #XX -- [ Pg.177 , Pg.178 ]




SEARCH



Analytic derivatives

Analytical derivatives

Analytical spectroscopies

Derivative spectroscopy

Derivative spectroscopy, analytical method

Derivative spectroscopy, analytical method Applications

© 2024 chempedia.info