Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Active protection systems application rates

Wide chemical variability without loss of biological properties --High efficacy against numerous phytopathogenic fungi —Systemic activity In some cases —Protective, curative and eradicative activity —Low application rates... [Pg.22]

Anodic protection possesses unique features. For example, the applied current is usually equal to the corrosion rate of the protected system. Thus, anodic protection not only protects but also offers a direct means for monitoring the corrosion rate of a system. The main advantages of anodic protection are (1) low current requirements (2) large reductions in corrosion rate (typically 10,000-fold or more) and (3) applicability to certain strong, hot acids and other highly corrosive media. It is important to emphasize that anodic protection can only be applied to metals and alloys possessing active-passive characteristics such as titanium, stainless steels, steel, and nickel-base alloys. [Pg.136]

During BMN-170 development, the design principles to provide plant safety was aimed at an optimum combination of reliance on intrinsic safety features and application of engineered (active and passive) systems. To be specific, the protection system being developed employs hydraulically suspended reactivity control rods that effectively influence the reactivity and convert the reactor to a sub critical state when flow rate is reduced through the core [XXI-9]. Use of a passive emergency cool down system allows complete removal of residual heat. [Pg.588]

Pressure detection shall be used for closed enclosure applications. Threshold detectors provide an electric signal when a preset overpressure is exceeded. Dynamic detectors provide an electric signal to the control and indicating equipment (CIE). Typically they have both rate-of-rise and pressure threshold triggering points that can be configured specifically to the application conditions. Although this type of detector minimizes spurious activation of the isolation system (due to pressure fluctuations other than explosion pressure rise), care shall be taken to set up such detectors to meet appropriate detection response criteria for the particular application and protected enclosure geometry. [Pg.20]


See other pages where Active protection systems application rates is mentioned: [Pg.396]    [Pg.475]    [Pg.396]    [Pg.404]    [Pg.252]    [Pg.26]    [Pg.101]    [Pg.63]    [Pg.166]    [Pg.1341]    [Pg.46]    [Pg.40]    [Pg.1341]    [Pg.994]    [Pg.116]    [Pg.172]    [Pg.475]    [Pg.994]    [Pg.243]    [Pg.355]    [Pg.197]    [Pg.198]    [Pg.857]    [Pg.85]    [Pg.90]    [Pg.404]    [Pg.284]    [Pg.113]    [Pg.15]    [Pg.172]    [Pg.26]    [Pg.1603]    [Pg.857]    [Pg.143]    [Pg.566]    [Pg.63]    [Pg.169]    [Pg.183]    [Pg.180]    [Pg.265]    [Pg.166]    [Pg.89]    [Pg.758]   
See also in sourсe #XX -- [ Pg.212 , Pg.213 ]




SEARCH



Activation rate

Active Protective System

Active applications

Active protection systems

Active protection systems applications

Activity ratings

Application rates

Applications system

Protection rates

Protection systems

Protection systems applications

Protective systems

Rating System

© 2024 chempedia.info