Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Absorption variation

The hydroxyl content of commercial material is kept low but it is to be observed that this has an effect on the water absorption. Variation in the residual acetate content has a significant effect on heat distortion temperature, impact strength and water absorption. The incorporation of plasticisers has the usual influence on mechanical and thermal properties. [Pg.393]

Intravenous administration no absorption problem Oral administration submitted to absorption variations... [Pg.1194]

Table 2. Application of Fourier Transform IR to Dehydration Studies of Epoxy Systems. Tentative Infrared Absorption Assignments for the Three Cured Epoxy Resins and the Absorption Variations During Degradation 18)... [Pg.82]

Again, CD changes are parallel to the remarkable absorption variations. Protonation at pH 2.3 of the H2TPyP peripheral nitrogens leads to aggregation and to about 90% of hypochromicity (Fig. 15, spectrum a) whereas deprotonation (at pH 9.0) restores the Soret intensity (Fig. 15, spectrum b). [Pg.163]

Ultrasonic absorption and viscosity measurements are reported on Figures 4 and 5 for the ATP and ATB systems. The viscosity and ultrasonic absorption variations for the hard-sphere-like microemulsion ATP versus 4> are progressive while for ATB microemulsion, viscosity and ultrasonic absorption data show a large anomaly around [Pg.80]

As a result of the nature of the photon emission there is no preference for a certain angle. However, the presence of local obstructions and absorption variations of the sample will have an influence on the distribution. Moreover the local variation of the specimen surface (topography)may result in variation of the internal reflection coefficient, and this reduces the efficiency for the light to get out of the specimen (analogous to light in an optical fiber)and induces local polarization of the light. [Pg.77]

To summarize several, in part unknown factors are responsible for the absorptivity variations of the 7.25 p band in amorphous polypropylenes the influence of any one of them may depend to an undefined extent upon the copolymer composition. Consequently, until the behaviour of this band has been further clarified, the use of amorphous polypropylene as a standard will entail some inaccuracy (perhaps a few units per cent) in the composition analysis of C2-C3 copolymers. [Pg.95]

Considerable thought has gone into devising absorption corrections. With the synchrotron, when there is not a requirement to use a particular wavelength for anomalous dispersion (see chapter 9), then as short a wavelength as possible is used to minimise absorption variations - see figure 6.3 - (and reduce radiation damage). This is a point that will be detailed later. [Pg.257]

Sample absorption can be a serious source of systematic error which can affect reflections in a set of equivalents differently or diminish the intensity of the equivalents in an overall way. The former problem can be avoided by measuring hkt and hkt only, since the absorption correction is identical for each, provided the sample is always fully bathed in a uniformly intense beam. If the absorption edge is at short wavelength (e.g. = 1 A) then, in the case of protein crystals, absorption variations are usually negligible for a typical-sized crystal. At longer wavelengths an absorption correction will become essential. [Pg.379]

Newer vehicles include liposomes and microgel formulations. Liposomes are concentric spherical shells of phospholipids in an aqueous medium that may enhance percutaneous absorption. Variations in size, charge, and hpid content can influence liposome function substantially. Liposomes penetrate compromised epidermal barriers more efficiently. Microgels are polymers that may enhance solubilization of certain drugs, thereby enhancing penetration and diminishing irritancy. [Pg.1076]

The first FOCS described for pH measurements was based on the absorption variations of Phenol Red [10]. This dye is copolymerized with a monomer of the acrylic type (5-10 pm diameter) [24]. Polystyrene microspheres (20<% with diameter 1 pm) improve the diffusion of light and provide a hydrophilic structure that is advantageous for ion transfer. The ratio (/, ) of the intensities at two wavelengths (558 nm at the peak and 478 nm at the isosbestic point) is related to the concentration and pH by the equation... [Pg.176]

The complexation of indole with a- and fi-CD caused a red shift of the absorption spectrum and a blue shift of the fluorescence emission. In the case of a-CD as complexing agent, the absorption variations were described by a sequential formation of 1 1 (K =2M ) and 2 1 (Aj = 210M ) complexes. Fluorescence quenching by CsCl was wavelength dependent and lower in presence of CD than in bulk water. This was attributed to dififerent absorption spectra for 1 1 and 2 1 complexes and to dififerent levels of protection offered by the two complexes against quenching by CsCl [254]. [Pg.68]

Factors that affect control of thyroid function in elderly persons include noncompliance with therapy, variability in absorption, variation in the biological activity of levothyroxine tablets, or the influence of drugs on TSH levels. Rapid changes in levothyroxine dose may also cause delays in the control of patients. The half life of T4 is about 1 week, but is longer in patients with hypothyroidism. This is the reason why a lapse of 3—6 weeks would be needed forT4 concentrations to reach a steady state and to evaluate the need for a change in dose. [Pg.1042]

Figure 20 Three traces obtained during the formation of cobalt boride particles, (a) Absorption variation of an aqueous solution and (b) that of an ethanolic cobalt chloride solution (0.1 M) during the reduction of the cobalt ions, (c) Trace obtained for the same reduction but in a Triton X-100 microemulsion sample ([Triton X-100] =1.5 M and / = 13.3). Note the small changes (W, E, and M) in absorbance due to addition of the reducing agent solution. Figure 20 Three traces obtained during the formation of cobalt boride particles, (a) Absorption variation of an aqueous solution and (b) that of an ethanolic cobalt chloride solution (0.1 M) during the reduction of the cobalt ions, (c) Trace obtained for the same reduction but in a Triton X-100 microemulsion sample ([Triton X-100] =1.5 M and / = 13.3). Note the small changes (W, E, and M) in absorbance due to addition of the reducing agent solution.
The main problem of submission of anthocyanins to UVA IS spectroscopy is the diversity of possible structures with different absorption properties and the lack of reliable calibration procedures. Hydrolysis of anthocyanins to anthocyanidins prior to measurement reduces possible UVA IS absorption variations in both, X max and e, to few well described structures. Yet another advantage of hydrolysis is that most anthocyanidins but only few anthocyanins are commercially available as reference standards for method calibration. The main disadvantages of acidic hydrolysis are that, oligomeric proanthocyanidins present in the sample are also hydrolyzed to anthocyanidins yielding possibly over-estimation of the original monomeric anthocyanin content. [Pg.145]

A change in the absorption of a medium in a resonant light field must be accompanied by a change in the refractive index of the medium, for the absorption variation A (cm ) is related to the refractive-index dispersion An by the Kramers-Kronig relation. In the particular case of a Lorentzian profile... [Pg.47]

The relaxation time did not depend on the parameters used to follow the kinetics, but only on the final temperature. It was found to be identical using optical rotation, absorption spectroscopy at different wavelengths, and fluorescence. Furthermore, when an extrinsic probe was used (fluorescence or absorption variations of the anthranyloyl group in anthranyloyl chymotrypsin) the same relation time was observed. [Pg.351]

The discovery of the fluorescence variation of pyrene-modified y-CD 1 upon addition of guests prompted the use of fluorophore-modified CD as chemosensors [9,10]. The pyrene-modified y-CD forms an association dimer in aqueous solution and exhibits excimer emission around 470 nm. The addition of a guest into the solution of the pyrene-modified y-CD causes a remarkable decrease in the excimer emission and an increase in the monomer emission around 378 and 397 nm. The guest-induced circular dichroism and absorption variations of 1 substantiated that this fluorescence variation occurs associated with the conversion from the association dimer to a 1 1 host-guest complex (Fig. 1). Since the... [Pg.267]

Geometry shown in Fig. 1 is subjected to differential fluxes of 55 % for the top and 75 % for the bottom surface. The absorptivity of the bulk is assumed as 0.5 and where as for the defect it is taken as 10 % more than the bulk. The defect size assumed as 300 microns. The sheet is subjected to a heating for 32 Sec to reach 220C. The temperature profiles on the bottom and top surface is shown in Fig. 8. From the Fig. 8, we can see that there is only 2C change in temperature at the bottom and 0.5C on top of the sheet. Thus the absorptivity variation has a minimal effect on temperature, and thus the differential strains. [Pg.2881]


See other pages where Absorption variation is mentioned: [Pg.314]    [Pg.102]    [Pg.314]    [Pg.69]    [Pg.82]    [Pg.94]    [Pg.314]    [Pg.110]    [Pg.349]    [Pg.172]    [Pg.231]   
See also in sourсe #XX -- [ Pg.148 ]




SEARCH



Regional variations, in percutaneous absorption

© 2024 chempedia.info