Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Absorption, determination mechanism

A very common and useful approach to studying the plasma polymerization process is the careful characterization of the polymer films produced. A specific property of the films is then measured as a function of one or more of the plasma parameters and mechanistic explanations are then derived from such a study. Some of the properties of plasma-polymerized thin films which have been measured include electrical conductivity, tunneling phenomena and photoconductivity, capacitance, optical constants, structure (IR absorption and ESCA), surface tension, free radical density (ESR), surface topography and reverse osmosis characteristics. So far relatively few of these measurements were made with the objective of determining mechanisms of plasma polymerization. The motivation in most instances was a specific application of the thin films. Considerable emphasis on correlations between mass spectroscopy in polymerizing plasmas and ESCA on polymer films with plasma polymerization mechanisms will be given later in this chapter based on recent work done in this laboratory. [Pg.13]

It is interesting to compare the results obtained for ordinary and heavy water. To interpret the difference, we show in Fig. 33 by solid curves the total absorption attained in the R-band (i.e., near the frequency 200 cm-1). Dashed curves and dots show the components of this absorption determined, respectively, by a constant (in time) and by a time-varying parts of a dipole moment. In the case of D20, the R-absorption peak vR is stipulated mainly by nonrigidity of the H-bonded molecules, while in the case of H20 both contributions (due to vibration and reorientation) are commensurable. Therefore one may ignore, in a first approximation, the vibration processes in ordinary water as far as it concerns the wideband absorption frequency dependences (actually this assumption was accepted in Section V, as well is in many other publications (VIG), [7, 12b, 33, 34]. However, in the case of D20, where the mean free-rotation-frequency is substantially less than in the case of H20, neglecting of the vibrating mechanism due to nonrigid dipoles appears to be nonproductive. [Pg.214]

Two-component IPN foams consisting of polyurethane and epoxy were prepared by the one-shot, free-rise method. The effects of PU/E ratio on the sound absorption and mechanical energy attenuation characteristics were determined with varying levels of different fillers and plasticizers. The formulations (Table IX) were based on the best elastomer results. An average of over 90X absorption was obtained at high frequencies by the Impedance tube method. However, this average drops dramatically at low frequencies. This reduction may be seen in Figs. 3 and 4 for 90/10 and 70/30 IPN foams vlth 20X... [Pg.289]

Acid-base interactions have found numerous applieations in research dealing with adsorption of molecules of liquids on the surfaees of solids. The main focus of this research is to estimate the thermodynamic work of adhesion, determine mechanism of interactions, analyze the morphology of interfaces and various surfaee coatings, develop surface modifiers, study the aggregation of macromolecular materials, explain the kinetics of swelling and drying, understand the absorption of low molecular weight compounds in polymeric matrices, and determine the properties of solid surfaces. In addition to these, there are many other applieations. [Pg.565]

In summary, there are many more tests that are used to explore additional properties of adhesives. This chapter has reviewed only the more commonly used tests for determining mechanical properties. Examples of other properties that may be tested for include impact strength, moisture absorption, corrosion, and attack by rodents and insects, just to name a few. The reader is referred to the ASTM Book of Standards Vol. 15.06 (revised and published annually) or the ISO counterpart for further details on the above and many other test standards. [Pg.232]

Studies to determine the nature of intermediate species have been made on a variety of transition metals, and especially on Pt, with emphasis on the Pt(lll) surface. Techniques such as TPD (temperature-programmed desorption), SIMS, NEXAFS (see Table VIII-1) and RAIRS (reflection absorption infrared spectroscopy) have been used, as well as all kinds of isotopic labeling (see Refs. 286 and 289). On Pt(III) the surface is covered with C2H3, ethylidyne, tightly bound to a three-fold hollow site, see Fig. XVIII-25, and Ref. 290. A current mechanism is that of the figure, in which ethylidyne acts as a kind of surface catalyst, allowing surface H atoms to add to a second, perhaps physically adsorbed layer of ethylene this is, in effect, a kind of Eley-Rideal mechanism. [Pg.733]

An important application of photochemical initiation is in the determination of the rate constants which appear in the overall analysis of the chain-growth mechanism. Although we shall take up the details of this method in Sec. 6.6, it is worthwhile to develop Eq. (6.7) somewhat further at this point. It is not possible to give a detailed treatment of light absorption here. Instead, we summarize some pertinent relationships and refer the reader who desires more information to textbooks of physical or analytical chemistry. The following results will be useful ... [Pg.356]

The mechanism of interaction with DNA is suggested. Ethidium bromide (EB) displacement assay was performed. We determine the binding constant of Tb-E to DNA to be in the order of Ig K = 6.47 0.4. The bathochromic and hypsochromic effects in the absorption spectra of investigated complex were observed and the interaction is assumed to be mainly of the mono-intercalating type. [Pg.377]

Whereas mechanical properties are largely determined by chain length, the softening point, hardness, water absorption and solubility are rather more determined by the degree of substitution (see Figure 22.6). [Pg.630]

Surface analysis has made enormous contributions to the field of adhesion science. It enabled investigators to probe fundamental aspects of adhesion such as the composition of anodic oxides on metals, the surface composition of polymers that have been pretreated by etching, the nature of reactions occurring at the interface between a primer and a substrate or between a primer and an adhesive, and the orientation of molecules adsorbed onto substrates. Surface analysis has also enabled adhesion scientists to determine the mechanisms responsible for failure of adhesive bonds, especially after exposure to aggressive environments. The objective of this chapter is to review the principals of surface analysis techniques including attenuated total reflection (ATR) and reflection-absorption (RAIR) infrared spectroscopy. X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and secondary ion mass spectrometry (SIMS) and to present examples of the application of each technique to important problems in adhesion science. [Pg.243]

Determining the number of theoretical and actual trays in a distillation column is only part of the design necessary to ensure system performance. The interpretation of distillation, absorption, or stripping requirements into a mechanical vessel with internal components (trays or packing, see Chapter 9) to carry out the function requires use of theoretical and empirical data. The costs of this equipment are markedly influenced by the column diameter and the intricacies of the trays, such as caps, risers, weirs, downcomers, perforations, etc. Calcvdated tray efficiencies for determination of actual trays can be lost by any unbalanced and improperly designed tray. [Pg.122]

The methods dependent upon measurement of an electrical property, and those based upon determination of the extent to which radiation is absorbed or upon assessment of the intensity of emitted radiation, all require the use of a suitable instrument, e.g. polarograph, spectrophotometer, etc., and in consequence such methods are referred to as instrumental methods . Instrumental methods are usually much faster than purely chemical procedures, they are normally applicable at concentrations far too small to be amenable to determination by classical methods, and they find wide application in industry. In most cases a microcomputer can be interfaced to the instrument so that absorption curves, polarograms, titration curves, etc., can be plotted automatically, and in fact, by the incorporation of appropriate servo-mechanisms, the whole analytical process may, in suitable cases, be completely automated. [Pg.8]


See other pages where Absorption, determination mechanism is mentioned: [Pg.267]    [Pg.345]    [Pg.267]    [Pg.326]    [Pg.302]    [Pg.244]    [Pg.446]    [Pg.131]    [Pg.5906]    [Pg.800]    [Pg.413]    [Pg.316]    [Pg.77]    [Pg.20]    [Pg.183]    [Pg.251]    [Pg.416]    [Pg.286]    [Pg.431]    [Pg.220]    [Pg.359]    [Pg.257]    [Pg.456]    [Pg.232]    [Pg.417]    [Pg.254]    [Pg.1063]    [Pg.42]    [Pg.35]    [Pg.696]    [Pg.162]    [Pg.141]    [Pg.203]    [Pg.23]    [Pg.995]   
See also in sourсe #XX -- [ Pg.202 ]




SEARCH



Absorption mechanisms

Mechanically determined

Mechanism determination

© 2024 chempedia.info