Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Work conversion factors

The system of atomic units was developed to simplify mathematical equations by setting many fundamental constants equal to 1. This is a means for theorists to save on pencil lead and thus possible errors. It also reduces the amount of computer time necessary to perform chemical computations, which can be considerable. The third advantage is that any changes in the measured values of physical constants do not affect the theoretical results. Some theorists work entirely in atomic units, but many researchers convert the theoretical results into more familiar unit systems. Table 2.1 gives some conversion factors for atomic units. [Pg.9]

This is the infamous Friedel-Crafts method and works in a manner similar to the previously mentioned method where P2P was made by merging benzene and chloroacetone using AICI3. This method is for speed makers only and is not recommended for conversion of 1,3-benzodioxole. However, this should work in a limited way on catechol. The conversion factor is very low but that isn t a major concern of speed chemists because cheap old benzene is the precursor and all of that benzene that isn t converted can be run back through this simple little process over and over again. Before she knows it, the chemist will have amassed an enormous amount of allylbenzene [139, 140]. [Pg.243]

The chapter on Radioactive chemicals (Chapter 11) has been updated. Considerations of safety in design (Chapter 12) are presented separately from systems of work requirements, i.e. Operating procedures (Chapter 13). Tlie considerations for Marketing and transportation of hazardous chemicals are now addressed in two separate chapters (Chapters 14 and 15). Chemicals and the Environment are now also covered in two chapters (Chapters 16 and 17) to reflect the requirement that the impact of chemicals on the environment should be properly assessed, monitored and controlled. Although a substantial contribution to atmospheric pollution is made by emissions from road vehicles and other means of transport, and this is now strictly legislated for, this topic is outside the scope of this text. Chapter 18 provides useful conversion factors to help with the myriad of units used internationally. [Pg.617]

Energy and work are interchangeable, and various terms and conversion factors are in common usage throughout the world today. These conversion factors are equivalencies unrelated to operational efficiencies because practical energy and work conversions are never 100% efficient. [Pg.10]

Therefore, if we work in pascals and cubic meters, the work is obtained in joules. However, we might have expressed the pressure in atmospheres and the volume in liters. In this case, we may need to convert the answer (in liter-atmospheres) into joules. The conversion factor is obtained by noting that 1 L = 10 3 m3 and 1 atm = 101 325 Pa exactly therefore... [Pg.340]

BEIs apply to 8 hr exposures, five days a week. However, BEIs for altered working schedules can be extrapolated on pharmacokinetic and pharmacodynamic bases. BEIs should not be applied, either directly or through a conversion factor, to the determination of safe levels for non-occupational exposure to air and water pollutants, or food contaminants. The BEIs are not intended for use as a measure of adverse effects or for diagnosis of occupational illness. [Pg.77]

It is usually the best practice to work through design calculations in the units in which the result is to be presented but, if working in SI units is preferred, data can be converted to SI units, the calculation made, and the result converted to whatever units are required. Conversion factors to the SI system from most of the scientific and engineering units used in chemical engineering design are given in Appendix D. [Pg.14]

Beginning students often regard the metric system as difficult because it is new to them and because they think they must learn all the English-metric conversion factors (Table 2-3). Engineers do have to work in both systems in the United States, but scientists generally do not work in the English system at all. Once you familiarize yourself with the metric system, it is much easier to work with than the English system is. [Pg.11]

MeV. WL-R = 100% x WL/radon concentrations (pCi/1). The dose conversion factor of 0.7 rad/working level month (WLM) (Harley and Pasternack, 1982) was used to calculate the mean absorbed dose to the epithelial cells and a quality factor (OF) of 20 was applied to convert the absorbed dose to dose equivalent rate. For example, from the average value of (WL) obtained from the arithmetic mean radon concentrations measured in the living area during winter and summer in South Carolina (Table I), the calculated dose equivalent rate is 4.1 rem/yr, e.g.,... [Pg.62]

The working level concept evaluates the unattached fraction and the activity median diameter in an indirect way, through the dose conversion factor. This paper will show that in the domestic environment this is mostly inaccurate to estimate the dose. [Pg.305]

Note Because there is a constant conversion factor between grams and pounds, we can work totally in pounds. Since the formula weights are CuFeS2 (183.5 g/mol), Cu2S (159.2 g/mol) and Cu (63.55 g/mol), we have... [Pg.32]

B Unfortunately, we cannot use the result of Example 26-5 ( 0.0045 u = 4.2 MeV ) because it is expressed to only two significant figures, and we begin with four significant figures. But, we essentially work backwards through that calculation. The last conversion factor is from Table 2-1. [Pg.605]

Examples. Let us now work out some examples. The energies are given in kcal/mol using the conversion factor 1 hartree = 627.51 kcal/mol. Distances... [Pg.140]

This works out because the ampere (the standard unit of current, abbreviated A) is defined as 1 coulomb per second. Because this equation gives you the amount of charge that has passed through the circuit during its operating time, all that remains is to calculate the number of moles of electrons that make up that amount of charge. For this, you use the conversion factor 1 mol e = 96,500 C. [Pg.267]

For each of the following pairs of units, work out a conversion factor F that will convert a measurement given in one unit to a measurement given in the other, and show the simple steps used in your work. [Pg.31]

If none of this work was wasted, we could use it to lift a 1000-lb rock up to the top of Mount Everest (which is about 26,000 ft high). But in the 1840s, Robert Mayer did not know the conversion factor of heat equivalent to work of 740 ft-lb per Btu. It had not been determined yet, because Dr. Mayer was the one who first discovered it. So Dr. Mayer had to use the following method. [Pg.359]

Molarity can be used as a conversion factor to relate a solution s volume to the number of moles of solute. If we know the molarity and volume of a solution, we can calculate the number of moles of solute. If we know the number of moles of solute and the molarity of the solution, we can find the solution s volume. Worked Examples 3.11 and 3.12 show how such calculations are done. [Pg.91]

For work in the laboratory, it s necessary to weigh reactants rather than just know numbers of moles. Thus, it s necessary to convert between numbers of moles and numbers of grams by using molar mass as the conversion factor. The molar mass of any substance is the amount in grams numerically equal to the substance s molecular or formula mass. Carrying out chemical calculations using these relationships is called stoichiometry. [Pg.106]

Note Although this problem is given to us and worked in mg/mL, any volumetric concentration units could have been used in this problem, so long as the same units are used throughout because the conversion factors cancel. [Pg.231]

When using conversion factors, there are two key points to remember. First, this method works only if you are meticulous in including units with all numerical data. Secondly, if your final answer has the correct units, the answer is probably correct. If your final answer has the wrong units, the answer is almost certainly incorrect. [Pg.21]

In the British system, the unit of work is called the foot-pound (ft-lb), because the pound is a unit of force and the foot is a unit of displacement. These units of work are all related by simple conversion factors. [Pg.82]


See other pages where Work conversion factors is mentioned: [Pg.1403]    [Pg.1403]    [Pg.250]    [Pg.221]    [Pg.1097]    [Pg.115]    [Pg.91]    [Pg.204]    [Pg.421]    [Pg.164]    [Pg.125]    [Pg.257]    [Pg.123]    [Pg.27]    [Pg.5]    [Pg.67]    [Pg.436]    [Pg.436]    [Pg.1047]    [Pg.72]   
See also in sourсe #XX -- [ Pg.656 ]




SEARCH



Conversion Factors

Conversions conversion factors

Work factor

Work units, conversion factors

Work-heat conversion factor

© 2024 chempedia.info