Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Wire rope sling

High-alloy or heat-treated vessels (since it would not be advisable for the field to be doing welding on these vessels after they arrive on site, and wire rope slings could contaminate the vessel material)... [Pg.387]

Table 19.3 shows the working load limits for a variety of wire rope slings made from 10mm diameter wire and operating at various angles (see BS EN 13414). [Pg.321]

Hgures 19.12. (a) Three-leg wire rope sling (b) Two-leg chain sling... [Pg.321]

Parts Holder Synthetic Web Sling. Use of synthetic web slings in areas where fiimes or vapors are present is a violation of OSHA 29 CFR 1910.184(i)(6). Constant exposure to solvent vapors could result in premature failure of synthetic web sling. Recommend use of wire rope sling instead. [Pg.81]

Example 15-5 A hoist with 10,000-lb capacity will lift a 7,500-lb (3.75 ton) load. A wire rope sling will lift the load. If the lift uses a vertical hitch, what size rope is needed to lift the load safely Consider two kinds of ropes ... [Pg.209]

Wire rope slings also require regular inspection because the first signs of failure often are not readily noticeable. A rope failure could result in a crippling ii jury or even death. [Pg.9]

Ensure that slingers understand that doubling up the sling does NOT double up the Safe Working Load avoid this practice if possible. Limit the use of endless wire rope slings. [Pg.670]

Ensure that wire rope slings are protected from sharp corners of the loads, by suitable packings. [Pg.670]

Wire rope slings shall have permanently I affixed, legible identification markings stating... [Pg.415]

Scaffolds shall be suspended from metal outriggers, brackets, wire rope slings, hooks, or means that meet equivalent criteria (e.g., strength, durability). [Pg.510]

Synthetic slings are protected from Abrasive, sharp or acute edges, and configurations that could cause a reduction of the sling s rated capacity, such as distortion or localized compression. Note Requirements for the protection of wire rope slings are contained in 29 CFR 1926.251(c)(9). [Pg.1237]

Eyes in wire rope slings must be fabricated with thimbles. [Pg.1272]

Bridle wire rope sling— A wire rope formed by plaiting component wire ropes. [Pg.347]

Cable laid endless sling-mechanical joint— A wire rope sling made endless by joining the ends of a single length of cable laid rope with one or more metallic fittings. [Pg.347]

Cable laid grommet-hand tucked—An endless wire rope sling made from one length of rope wrapped six times around a core formed by hand tucking the ends of the rope inside the six wraps. [Pg.347]

Cable laid rope sling-mechanical joint—A wire rope sling made from a cable laid rope with eyes fabricated by pressing or swagging one or more metal sleeves over the rope junction. [Pg.348]

Master link or gathering ring— A forged or welded steel link used to support all members (legs) of an alloy steel chain sling or wire rope sling. [Pg.348]

Wire rope slings must be used only with loads that do not exceed the rated capacities. [Pg.352]

Fiber core wire rope slings of all grades must be permanently removed from service if they are exposed to temperatures in excess of200°F. [Pg.352]

Describe the defects that might be identified in a wire rope sling during routine inspection prior to use. [Pg.230]

Ensure that all wire rope slings are inspected by a competent person for damage each day before use and additionally as conditions warrant. Damaged or defective slings must be immediately removed from service. See 29 CFR 1910.184(d). [Pg.40]

Remove wire rope slings from service if they show kinking, crushing, bird caging or other damage resulting in distortion. See OSHA standard 29 CFR 1910.184(f)(5)(iii). [Pg.40]

Wire rope slings shonld immediately be removed from service if any of the... [Pg.124]

BS 6166 Part 3 1988 Guide to selection and use of lifting slings for multi purposes BS 6210 1983 Code of Practice for the safe use of wire rope slings for general purposes... [Pg.209]

Are wire rope slings and cables inspected before use ... [Pg.407]

Do all attachments meet the same load standards as the wire rope sling they are attached to ... [Pg.407]

Are nonfiber core, wire rope slings only used at tanperatures below 400°F and above 60 F ... [Pg.407]