Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Water loading

A humidification subsystem controls the temperature, flow rate, and relative humidity of the sweep stream. Air and water can be fed to a Hquid-gas packed contactor to produce the desired moisture level ia the vapor stream. The saturation temperature controls the water loading of the air which can be heated to give exactly the desired relative humidity. [Pg.87]

The required desiccant weight is a function of several factors the water removal requirements (mass/time), the cycle time, the equiUbrium loading of water on the desiccant at the feed conditions, the residual water loading on the desiccant after regeneration, and the size of the mass-transfer zone of the desiccant bed. These factors, in turn, depend on the flow rate, temperature, pressure, and water content of both the fluid being dried and the regeneration fluid (see Adsorption, gas separation). [Pg.516]

The performance coefficients usually attained have been about 5.2 for water loadings in excess of 750 lb/(h-ft ), though new types of packing are improving... [Pg.1169]

Water Load Circulating rate of water over the tower, expressed in gallons per minute. [Pg.93]

The buttress dam uses much less concrete than the gravity dam, and also relies on its shape to transfer the water load. Buttress dams were developed in areas... [Pg.648]

Determine the inlet water temperature to the tower. This is approximately the oudet temperature from the cooling water load. [Pg.396]

In most cases, splitting the heating and domestic hot water loads will be advantageous. This avoids the inefficient use of a large boiler solely to heat a calorifier in the summer months. [Pg.279]

Excessive water loads can lead to malfunction of the distribution system. Higher loading in one area can lead to pack collapse and rapid falToff in performance. [Pg.530]

In order to make adjustments in the water load, the reabsorption of the remaining 20% of the filtered water from the distal tubule and the collecting duct is physiologically controlled by antidiuretic hormone (ADH), also referred to as vasopressin. Antidiuretic hormone, synthesized in the hypothalamus and released from the neurohypophysis of the pituitary gland, promotes the... [Pg.320]

Fig. 10.4 Schematic diagram of the microwave system for catalytic study 1. generator, 2. water load, 3. circulator, 4. switch,... Fig. 10.4 Schematic diagram of the microwave system for catalytic study 1. generator, 2. water load, 3. circulator, 4. switch,...
Table 3 Total loads (expressed as gram per day per 1,000 inhabitants) of pharmaceuticals detected in WWTP effluents that are afterwards discharged into receiving river waters. Loads are expressed as the range of the amounts detected in each sampling period altogether with average and mean values... Table 3 Total loads (expressed as gram per day per 1,000 inhabitants) of pharmaceuticals detected in WWTP effluents that are afterwards discharged into receiving river waters. Loads are expressed as the range of the amounts detected in each sampling period altogether with average and mean values...
Before moving on to true mass transport issues it is worthwhile to point out that the quantity vep(Y - Yp) is in fact the water load per unit of time (whichever units of time v is expressed in.) Further that with an a-priori design process we may not know the required cross sectional area for flow and hence it may be more convenient to multiply the above relationship by and thus obtain the adsorbable contaminant input rate ... [Pg.282]

As with the sweetening application our most common need for CO2 removal is from natural gas prior to liquefaction. In this application we are often faced with amounts of oxygen in the feed that may range up to several hundred ppm by volume. The process is often limited to adsorption at a total pressure of about 3 5 bar. In this application however the feed gas is most often pipeline natural gas which gas will have been pre-dried to pipeline standards or about seven pounds (1 lb = 0.45 kg) of water per MMSCF of gas. In some cases the gas source may be other than pipeline and the water load needs to be estimated based on a given mole fraction. The liquefaction process, which runs at -260°F (127°C), demands very low levels of water in the product as well as trace levels of CO2 so that the heat exchangers in the downstream process remain clean. [Pg.295]

There are not many models that do transients, mainly because of the computational cost and complexity. The models that do have mainly been discussed above. In terms of modeling, the equations use the time derivatives in the conservation equations (eqs 23 and 68) and there is still no accumulation of current or charging of the double layer that is, eq 27 still holds. The mass balance for liquid water requires that the saturation enter into the time derivative because it is the change in the water loading per unit time. However, this treatment is not necessarily rigorous because a water capacitance term should also be included,although it can be neglected as a first approximation. [Pg.480]

Replace the water load with 100 mL distilled water at 25°C. [Pg.321]

The sources of wastewater generation in petroleum refineries have been discussed previously in this chapter. Table 5 presents a qualitative evaluation of wastewater flow and characteristics by fundamental refinery processes [5]. The trend of the industry has been to reduce wastewater production by improving the management of the wastewater systems. Table 6 shows waste-water loadings and volumes per unit fundamental process throughput in older, typical, and newer technologies [15]. Table 7 shows typical wastewater characteristics associated with several refinery processes [16]. [Pg.256]

Air streams from the digestion system, vacuum cooler, concentrator, and other areas where fluorine is evolved are connected to a highly efficient absorption system, providing extremely high volumes of water relative to the stream. The effluent from this absorption system forms part of the recycled water and is eventually discharged as part of the product used for fertilizer manufacture. The Minnesota plant requires a constant recirculating water load in excess of 3000 gpm (11.4 m /min), but multiple use and recycle reduce makeup requirements to less than 400 gpm (1.5 m /min) or a mere 13% of total water use. [Pg.437]

Glucocorticoids maintain normal glomerular filtration rate. The adrenalectomized animal can not excrete a water load and tend to develop water intoxication and this can be treated by glucocorticoids. [Pg.282]


See other pages where Water loading is mentioned: [Pg.276]    [Pg.157]    [Pg.513]    [Pg.1169]    [Pg.1169]    [Pg.74]    [Pg.1217]    [Pg.193]    [Pg.766]    [Pg.766]    [Pg.788]    [Pg.80]    [Pg.83]    [Pg.731]    [Pg.595]    [Pg.443]    [Pg.69]    [Pg.71]    [Pg.72]    [Pg.444]    [Pg.21]    [Pg.209]    [Pg.212]    [Pg.220]    [Pg.28]    [Pg.125]    [Pg.292]    [Pg.459]    [Pg.321]    [Pg.241]    [Pg.71]    [Pg.53]    [Pg.138]   
See also in sourсe #XX -- [ Pg.102 ]

See also in sourсe #XX -- [ Pg.102 ]




SEARCH



Pressurized water reactors thermal loads

Retrofitting Selected Water Networks for Increase in Hydrocarbon Load

Revamping Selected Water Networks for Increase in Hydrocarbon Load

River water suspended load normalization

Typical cooling tower performance curves for different water loadings

WWTPs water/nutrient loads

Water discharge dissolved load

Water loading uncertainty

Water organic chemical load

© 2024 chempedia.info