Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Vibrational signals

Vibration analysis This ineludes an on-line analysis of the vibration signals, FFT speetral analysis, transient analysis, and diagnosties. A wide variety of displays are available ineluding orbits, easeades, bode and nyquist plots, and transient plots. [Pg.648]

During the startup, all vibration signals should be tape reeorded. The reeordings ean be analyzed and plotted to provide baseline vibration data for future evaluation of maehine performanee. [Pg.767]

This section provides information needed to understand and solve the majority of balancing problems using a vibration/balance analyzer, a portable device that detects the level of imbalance, misalignment, etc., in a rotating part based on the measurement of vibration signals. [Pg.936]

Fig. 1.1. TOF data for I2 as a function of time delay in a pump-probe experiment showing a variety of vibrational signals in the I+ signal. The horizontal band at 5,145 ns corresponds to metastable t] 1. The pair of bands at 5,020 and 5,270 ns corresponds to the I+ + I+ dissociation channel, while the signal in between these bands corresponds to I+ + I. Pump and probe are both 25 fs, 800 nm pulses... Fig. 1.1. TOF data for I2 as a function of time delay in a pump-probe experiment showing a variety of vibrational signals in the I+ signal. The horizontal band at 5,145 ns corresponds to metastable t] 1. The pair of bands at 5,020 and 5,270 ns corresponds to the I+ + I+ dissociation channel, while the signal in between these bands corresponds to I+ + I. Pump and probe are both 25 fs, 800 nm pulses...
A special O-ring cell design is needed for in situ infrared (IR) vibrational characterization of an electrochemical interface. The absorption of one monolayer (i.e. <1015 cm 2 vibrators) can be measured if the silicon electrode is shaped as an attenuated total reflection (ATR) prism, which allows for working in a multiple-in-ternal-reflection geometry. A set-up as shown in Fig. 1.9 enhances the vibrational signal proportional to the number of reflections and restricts the equivalent path in the electrolyte to a value close to the product of the number of reflections by the penetration depth of the IR radiation in the electrolyte, which is typically a tenth of the wavelength. The best compromise in terms of sensitivity often leads to about ten reflections [Oz2]. [Pg.20]

If the vendor can demonstrate that there is electrical or mechanical runout of the rotor surfaees at the proximity probes (see 2.5.9), a maximum of 25 pereent of the measured value or 6 microns (0.25 mils), whichever is greater, may be vectorially subtracted from the vibration signal measured during the shop test. [Pg.34]

D. Daniher, L. Briens, A. Tallevi, End-point detection in high-shear granulation using sound and vibration signal analysis. Powder Technol., 181, Issue 2, 130-136 6 (2008). [Pg.302]

The wandering spider Cupiennius salei (Ctenidae) deposits a pheromone on its silk. This cue triggers vibrational signaling by males, to which a receptive female... [Pg.126]

There are two main approaches or configurations for the AFM-assisted detection of the local piezoelectric activity (pfm) in ferroelectric thin films for ferroelectric memory applications (FeRAM). The most used one was introduced in the early 90s and uses a conductive afm-tip as both top electrode and sensor for the induced vibration [2-4]. The second and more recent one [15,16], uses a normal metallic thin top electrode to apply the electric field and the vibration signal is detected by the AFM-tip above the top electrode. Both approaches present numerous advantages and disadvantages, as widely discussed in the literature, and are quite complementary. [Pg.359]

Lewis, L.A., Schneider, S.S. and Degrandi-Hoffman, G. (2002). Factors influencing the selection of recipients by workers performing vibration signals in colonies of the honeybee, Apis mellifera. Anim. Behav., 63, 361-367. [Pg.252]

Technicians require minimal effort to generate surveillance and summary reports, once the vibration data is collected. The vibration signals from the operating equipment is computer classified using proprietary computer programs into three levels of operation (1) Smooth, (2) Marginal, and (3) Rough. [Pg.210]

Subtraction of the resolution function reveals the vibrational contribution S (v) to the excitation probability. PHOENIX adjusts the subtraction weight to achieve the best match to the one-phonon contribution to the vibrational signal near Eq expected for a Debye frequency distribution (D (v) a v y The Fourier-log algorithm then yields the dominant first-order vibrational contribution... [Pg.6253]


See other pages where Vibrational signals is mentioned: [Pg.1786]    [Pg.378]    [Pg.40]    [Pg.2]    [Pg.57]    [Pg.65]    [Pg.32]    [Pg.71]    [Pg.297]    [Pg.294]    [Pg.373]    [Pg.246]    [Pg.359]    [Pg.92]    [Pg.682]    [Pg.45]    [Pg.53]    [Pg.6248]    [Pg.6249]    [Pg.6251]    [Pg.6253]    [Pg.6262]    [Pg.687]    [Pg.356]    [Pg.94]    [Pg.199]    [Pg.260]    [Pg.1786]    [Pg.403]    [Pg.6247]    [Pg.6248]    [Pg.6250]    [Pg.6252]    [Pg.6261]   
See also in sourсe #XX -- [ Pg.40 , Pg.45 , Pg.53 ]

See also in sourсe #XX -- [ Pg.126 , Pg.127 ]

See also in sourсe #XX -- [ Pg.40 , Pg.45 , Pg.53 ]




SEARCH