Vertical tubes

The flows of gas and liquid need not be concentric for aerosol formation and, indeed, the two flows could meet at any angle. In the cross-flow nebulizers, the flows of gas and sample solution are approximately at right angles to each other. In the simplest arrangement (Figure 19.11), a vertical capillary tube carries the sample solution. A stream of gas from a second capillary is blown across this vertical tube and creates a partial vacuum, so some sample solution lifts above the top of the capillary. There, the fast-flowing gas stream breaks down the thin film of sample... [Pg.144]

One drawback of static crystallization is that crystal layer growth rates are very slow. In the Sulzer MWB process, growth rates are gready improved by allowing a film to dow down vertical tubes (83). [Pg.419]

The vertical tube (water-cooled) generator consists of two concentric tubes the outer of which is cooled with water and acts as the ground electrode. Feed gas is introduced into the top of the inner stainless steel tube (which serves as the high voltage electrode), exits at the bottom of the outer tube, flows upward through the aimular space (which contains the electric discharge), and emerges at the top of the outer tube into a product gas manifold. [Pg.500]

In fossil fuel-fired boilers there are two regions defined by the mode of heat transfer. Fuel is burned in the furnace or radiant section of the boiler. The walls of this section of the boiler are constmcted of vertical, or near vertical, tubes in which water is boiled. Heat is transferred radiatively from the fire to the waterwaH of the boiler. When the hot gas leaves the radiant section of the boiler, it goes to the convective section. In the convective section, heat is transferred to tubes in the gas path. Superheating and reheating are in the convective section of the boiler. The economizer, which can be considered as a gas-heated feedwater heater, is the last element in the convective zone of the boiler. [Pg.358]

The compressor can be driven by electric motors, gas or steam turbiaes, or internal combustion (usually diesel) engines. The compressor can also be a steam-driven ejector (Fig. 7b), which improves plant reUabiUty because of its simplicity and absence of moving parts, but also reduces its efficiency because an ejector is less efficient than a mechanical compressor. In all of the therm ally driven devices, turbiaes, engines, and the ejector mentioned hereia, the exhaust heat can be used for process efficiency improvement, or for desalination by an additional distillation plant. Figure 8 shows a flow diagram of the vertical-tube vapor compression process. [Pg.246]

Fig. 8. Pictorial view (a) and flow diagram (b) for a vertical-tube vapor-compression process. Courtesy of Resources Conservation Co. Fig. 8. Pictorial view (a) and flow diagram (b) for a vertical-tube vapor-compression process. Courtesy of Resources Conservation Co.
For laminar flow in vertical tubes a series of charts developed by Pigford [Chem. Eng. Prog. Symp. Sen 17, 51, 79 (1955)] maybe used to predict values of... [Pg.561]

Falling Films When a hquid is distributed uniformly around the peripheiy at the top of a vertical tube (either inside or outside) and allowed to fall down the tube wall by the influence of gravity, the fluid... [Pg.561]

For the turbulent flow of water in layer form down the walls of vertical tubes the dimensional equation of McAdams, Drew, and Bays [Trans. Am. Soc. Mech. Eng., 62, 627 (1940)] is recommended ... [Pg.562]

Vertical Tubes For the following cases Reynolds number < 2100 and is calculated by using F = Wp/ KD. The Nusselt equation for the heat-transfer coefficient for condensate films may be written in the following ways (using liquid physical properties and where L is the cooled lengm and At is — t,) ... [Pg.566]

FIG. 5-9 Chart for determining film coefficient for film-type condensation of pure vapor, based on Eqs. 5-88 and 5-93. For vertical tubes multiply by 1.2. If 4F/ J exceeds 2100, use Fig. 5-10. is in U.S. customary units to convert feet to... [Pg.567]

H. Vertical tubes, laminar flow, forced and natural convection... [Pg.608]

Laminar Flow For films falling down vertical flat surfaces, as shown in Fig. 6-52, or vertical tubes with small film thickness compared to tube radius, laminar flow conditions prevail for Reynolds numbers less than about 2,000, where the Reynolds number is given by... [Pg.668]

These equations assume that there is no drag force at the gas/liquid interface, such as would be produced by gas flow. For a flat surface inclined at an angle 0 with the horizontal, the preceding equations may be modified by replacing g by g sin 0. For films falhng inside vertical tubes with film thickness up to and including the full pipe radius, see Jackson AlChE1, 231-240 [1955]). [Pg.669]

Rotameter A rotameter consists of a vertical tube with a tapered bore in which a float changes position with the flow rate through the tube. For a given flow rate the float remains stationary since the vertical forces of differential pressure, gravity, viscosity, and buoyancy are balanced. The float position is the output of the meter and can be made essentially linear with flow rate by makiug the tube areavaiy hn-early with the vertical distance. [Pg.762]

Vertical In-Shell Condensers Condensers are often designed so that condensation occurs on the outside of vertical tubes. Equation (5-88) is valid as long as the condensate film is laminar. When it becomes turbulent. Fig. 5-10 or Colburns equation [Tran.s. Am. Jn.st. Chem. Ertg., 30, 187 (1933-1934) maybe used. [Pg.1042]

Forced-Recirculation Reboilers In forced-recirculation reboilers, a pump is used to ensure circiilation of the liquid past the heattransfer surface. Force-recirculation reboilers may be designed so that boiling occurs inside vertical tubes, inside horizontal tubes, or on the shell side. For forced boihng inside vertical tubes. Fair s method (loc. cit.) may be employed, making only the minor modification that the recirculation rate is fixed and does not need to be balanced against the pressure available in the downcomer. Excess pressure required to circiilate the two-phase fluid through the tubes and back into the column is supphed by the pump, which must develop a positive pressure increase in the hquid. [Pg.1043]


See other pages where Vertical tubes is mentioned: [Pg.70]    [Pg.36]    [Pg.323]    [Pg.436]    [Pg.9]    [Pg.149]    [Pg.181]    [Pg.869]    [Pg.869]    [Pg.110]    [Pg.64]    [Pg.502]    [Pg.38]    [Pg.206]    [Pg.219]    [Pg.499]    [Pg.500]    [Pg.78]    [Pg.318]    [Pg.407]    [Pg.407]    [Pg.418]    [Pg.244]    [Pg.245]    [Pg.246]    [Pg.289]    [Pg.291]    [Pg.552]    [Pg.669]    [Pg.669]    [Pg.669]    [Pg.889]    [Pg.1042]    [Pg.1045]   
See also in sourсe #XX -- [ Pg.168 , Pg.178 ]




SEARCH



Boiling in vertical tubes

Bubble-flow vertical tubes

Condensation inside and outside vertical tubes

Condensation on vertical and horizontal tubes

Condensation outside vertical tubes

Enclosed vertical tubes

Evaporation recirculation long-tube vertical

Evaporation short-tube vertical evaporator

Evaporator long-tube vertical

Evaporator recirculation long-tube vertical

Evaporator short-tube vertical

Evaporators Short tube vertical

Evaporators long-tube vertical

Flooding in vertical tubes

Heat transfer in vertical tubes

Heat transfer, fluidized beds vertical tubes

Reactor vertical tube

Recirculation long-tube vertical

Slug flow in vertical tubes

Slug-flow vertical tubes

Tubes vertical, condensation

Upper Limit Flooding in Vertical Tubes

Vertical tube apparatus

Vertical tube evaporator

Vertical tube evaporators

Vertical-tube vapor-compression process