Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Underwriters Laboratories, Inc

UE 94 Standardfor Safety, Tests for Flammability of Plastic Materials for Parts in Devices and Appliances, Underwriters Laboratories, Inc., Northbrook, lU.,... [Pg.473]

The limiting oxygen index of Tefzel as measured by the candle test (ASTM D2863) is 30%. Tefzel is rated 94 V-0 by Underwriters Laboratories, Inc., in their burning test classification for polymeric materials. As a fuel, it has a comparatively low rating. Its heat of combustion is 13.7 MJ/kg (32,500 kcal/kg) compared to 14.9 MJ /kg (35,000 kcal/kg) for poly(vinyHdene fluoride) and 46.5 MJ /kg (110,000 kcal/kg) for polyethylene. [Pg.370]

Underwriters Laboratories Inc., Standards forA.cetylene Generators No. 297 Portable Medium Pressure, May 1973 No. 408 Stationay Medium Pressure, May 1973. [Pg.382]

Kecogni d Component Directory, Vol. 2, Underwriters Laboratories Inc., Northbrook, Dl., 1994. [Pg.453]

A. F. Matson, R. E. Dufour, andj. E. Breen, Survey of Available Information on Ignition of Wood Exposed to Moderately Elevated Temperatures, Bulletin of Research 51, Part II, Underwriters Laboratories, Inc., 1959. [Pg.335]

Underwriters Laboratories Inc. has published the following tank standards ... [Pg.1016]

MESG is defined in terms of die precise test mediod and apparatus used, of which there are three variants British, lEC, and Underwriters Laboratories, Inc. Each apparatus consists of two combusdon chambers connected by a slot of specified size and variable widdi. The separate chambers are filled with the test mixture. The MESG is die maximum slot widdi that prevents flame propagadoii between die chambers for all composi-doiis of die test gas in air under the specified test coiididoiis. Phillips (1987) describes and compares diese three types of experimental apparatus for determining the MESG. [Pg.100]

Underwriters Laboratories Inc. (UL) and Factory Mntnal Research (FM) will condnct tests for flame arrester mannfactnrers to ascertain if a designated flame arrester (deflagration or detonation type) will prevent passage of a flame of a specific gas. Both UL and FM test procednres also inclnde tests for endnrance bnrning, and in the case of UL tests, also for continnons flames. [Pg.191]

Outline of Investigation for Household and Commercial Batteries, Subject 2054, Underwriters Laboratories, Inc. September 7, 1993. [Pg.562]

Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II and III, Division 1, Hazardous Locations, UL 913, Underwriters Laboratories, Inc., Northbrook, IL, July 1979 Installation of Intrinsically Safe Instrument Systems in Class I Hazardous Locations, ISA-RP12.6, Instrument Society of America, Research Triangle Park, NC... [Pg.267]

Underwriters Laboratories Inc. (UL), UL 674, Safety Electric Motors and Generators for Use in Division 1 Hazardous (Classified) Locations, Third Edition, UL, Northbrook, IL, 1994. [Pg.153]

Underwriters Laboratories Inc. (UL) UL is an independent, not-for-profit product safety testing and certification organization. UL has tested products for public safety for more than a century with more than 14 billion UL Marks applied to products worldwide. UL has developed a standard for inverters that can be applied to fuel cells. [Pg.335]

UL2054, Household and Commercial Batteries. Underwriters Laboratories, Inc. [Pg.221]

Safety Standard for Lithium Batteries, UL 1642, Underwriters Laboratories Inc, Third Edition, 1995. [Pg.221]

ASTM E 1529 Standard Test Methods for Determining Effects of Large Eiydrocarbon Pool Fires on Structural Members and Assemblies and Underwriters Laboratories Inc. 1709 Standard for Rapid Rise Fire Tests of Protection Materials for Structural Steel are two tests which are used to evaluate the performance of structures, equipment, and protective materials to hydrocarbon fires (see Figure 5-17). [Pg.85]

Underwriters Laboratories Inc. standards for steel ASTs storing flammable and combustible liquids include the following ... [Pg.141]

Printing Office(1946) 5 )H. W.Heinrich. Indus trial Accident Prevention A Scientific Approach5, 3rd ed, McGraw-Hill,NY( 1950) 6)National Safety Council,"Accident Prevention Manual for Industrial Operations, 2nd ed, Chicago,111(1951) 7)Underwriters Laboratories,Inc, Lists Relating to Accident Equipment , NY(1951) 8)National Fire Protection Association,"National Fire Codes for the Prevention of Dust Explosions, Bostoh(1952) 9)W.M.Kunstler,"The Law of Accidents, Oceana Publications,NY( 1954) 10)US Bureau of Mines,"Accidents from Explosives at Metal and Non-metallic Mines, JuIy(1956)(See also Safety Measures in Industry)... [Pg.12]


See other pages where Underwriters Laboratories, Inc is mentioned: [Pg.379]    [Pg.529]    [Pg.181]    [Pg.185]    [Pg.233]    [Pg.551]    [Pg.99]    [Pg.133]    [Pg.146]    [Pg.183]    [Pg.349]    [Pg.221]    [Pg.12]    [Pg.529]    [Pg.22]   
See also in sourсe #XX -- [ Pg.551 ]




SEARCH



Underwriters

Underwriters Laboratories

© 2024 chempedia.info