Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Thin determination

By many properties emulsion aqueous films are analogous to foam films. There are several review articles dedicated to properties of emulsion aqueous films [e.g. 320,503-506]. The properties of microscopic emulsion aqueous films (kinetics of thinning, determination of equilibrium thickness, etc.) are studied employing devices quite similar to those used for foam films [503]. Analogous to foam films, stable (metastable) emulsion films are formed only in the presence of surfactants (emulsifiers) at concentrations higher than the critical concentration of formation of black spots C or the concentration, corresponding to... [Pg.303]

The analysis of the curves obtained in the thin-skin regime ean lead to a simple determination of slot length depending on the dimension of the probe chosen for the inspection. If the size of the probe (outer diameter) is smaller than the defect length we can notice 5 zones relative to the relationship between the position of the probe, the interaction of the induced eddy current and the slot, and the impedance change for the probe. [Pg.146]

The most widely used experimental method for determining surface excess quantities at the liquid-vapor interface makes use of radioactive tracers. The solute to be studied is labeled with a radioisotope that emits weak beta radiation, such as H, C, or One places a detector close to the surface of the solution and measures the intensity of beta radiation. Since the penetration range of such beta emitters is small (a ut 30 mg/cm for C, with most of the adsorption occurring in the first two-tenths of the range), the measured radioactivity corresponds to the surface region plus only a thin layer of solution (about 0.06 mm for C and even less for H). [Pg.77]

In the case of Langmuir monolayers, film thickness and index of refraction have not been given much attention. While several groups have measured A versus a, [143-145], calculations by Knoll and co-workers [146] call into question the ability of ellipsometry to unambiguously determine thickness and refractive index of a Langmuir monolayer. A small error in the chosen index of refraction produces a large error in thickness. A new microscopic imaging technique described in section IV-3E uses ellipsometric contrast but does not require absolute determination of thickness and refractive index. Ellipsometry is routinely used to successfully characterize thin films on solid supports as described in Sections X-7, XI-2, and XV-7. [Pg.126]

A thin film of hydrocarbon spread on a horizontal surface of quartz will experience a negative dispersion interaction. Treating these as 1 = quartz, 2 = n-decane, 3 = vacuum, determine the Hamaker constant A123 for the interaction. Balance the negative dispersion force (nonretarded) against the gravitational force to find the equilibrium film thickness. [Pg.251]

Parikh A N and Allara D L 1992 Quantitative determination of moleoular struoture in multilayered thin films of... [Pg.1796]

A-4-Thiazoline-2-thione and derivatives can be determined in mixtures as a result of sv Stematic studies on thin-layer-chromatography values... [Pg.385]

V. Other physical determinations w. Thin-layer chromatography X. X-ray diffraction z. Optical properties... [Pg.3]

From the arguments of the present section it is clear that an inverse relationship holds between the specific surface and the particle size, and if the particles are long or thin it is the minimum dimension, the thickness of the plates or of the rods, which mainly determines the magnitude of the specific surface. [Pg.35]

When first developed, potentiometry was restricted to redox equilibria at metallic electrodes, limiting its application to a few ions. In 1906, Cremer discovered that a potential difference exists between the two sides of a thin glass membrane when opposite sides of the membrane are in contact with solutions containing different concentrations of H3O+. This discovery led to the development of the glass pH electrode in 1909. Other types of membranes also yield useful potentials. Kolthoff and Sanders, for example, showed in 1937 that pellets made from AgCl could be used to determine the concentration of Ag+. Electrodes based on membrane potentials are called ion-selective electrodes, and their continued development has extended potentiometry to a diverse array of analytes. [Pg.465]

The size of the droplets formed in an aerosol has been examined for a range of conditions important in ICP/MS and can be predicted from an experimentally determined empirical formula (Figure 19.6). Of the two terms in the formula, the first is most important, except at very low relative flow rates. At low relative velocity of liquid and gas, simple droplet formation is observed, but as the relative velocity increases, the stream of liquid begins to flutter and to break apart into long thinner streamlets, which then break into droplets. At even higher relative velocity, the liquid surface is stripped off, and the thin films so-formed are broken down into... [Pg.140]


See other pages where Thin determination is mentioned: [Pg.704]    [Pg.704]    [Pg.142]    [Pg.868]    [Pg.79]    [Pg.81]    [Pg.257]    [Pg.272]    [Pg.362]    [Pg.370]    [Pg.523]    [Pg.188]    [Pg.437]    [Pg.442]    [Pg.81]    [Pg.1037]    [Pg.30]    [Pg.116]    [Pg.394]    [Pg.493]    [Pg.253]    [Pg.237]    [Pg.241]    [Pg.288]    [Pg.20]    [Pg.192]    [Pg.37]    [Pg.134]    [Pg.316]    [Pg.417]    [Pg.544]    [Pg.311]    [Pg.448]    [Pg.160]    [Pg.287]    [Pg.171]    [Pg.178]    [Pg.181]    [Pg.183]    [Pg.198]    [Pg.201]   
See also in sourсe #XX -- [ Pg.336 , Pg.337 ]




SEARCH



Thin films property determinants

Thin films thickness determination

© 2024 chempedia.info