Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Termination procedures

Final Transactional Closure and Reconciliation of Materials and Costs Termination procedures should outline who will have responsibility for assuring residual activities, material shipments, and processing has ceased. It is wise for both parties to confirm that this last step is complete. Normally, residual service activities and material supply ceases once the final invoice has been generated. [Pg.134]

Histopathology testing is a terminal procedure, and, therefore, sampling of any single animal is a one-time event (except in the case of a tissue collected by biopsy). Because it is a regulatory requirement that the tissues from a basic number of... [Pg.253]

Development of a new acetylene terminating procedure to facilitate the synthesis of the aforementioned systems. [Pg.19]

In the context of schistosomiasis, where parasites do not multiply in the mammalian host, protective immunity is primarily measured as a reduction in the adult worm burden of vaccinated animals relative to controls. Conventionally, this has been assessed by a terminal procedure involving perfusion of the portal... [Pg.304]

Termination procedures (all listed implementation features must be present) Procedures for the ending of an employee s employment or an intemal/extemal user s access. Combination locks changed Removal from access lists Removal of user account(s) Return of keys, tokens, or cards that allow access... [Pg.236]

Most businesses have a procedure for terminating employees, so the manager simply follows that procedure. Most termination procedures require that a witness be present during the meeting to verify conversations and actions. [Pg.161]

DNA can be sequenced by the chemical method or the chain termination procedure. The latter is now the method of choice in which the (single-stranded) DNA to be sequenced serves as the template for the synthesis of a complementary strand when supplied with a specific primer and E. coli DNA polymerase I. [Pg.260]

The real breakthrough was the appreciation of the limitations inherent in trying to modify RNA sequencing methods to suit the DNA problem. In this respect it is perhaps fortunate that enzymes with the type of base specificity exhibited by the RNA endonucleases are not available for degrading DNA and this also played its part in driving the development of the modern chemical and chain termination procedures for DNA sequence analysis. [Pg.2]

Fig. 4.12. Principle of the dideoxynucleotide chain-termination procedure. Primer ( ) is annealed to the single-stranded template at a site adjacent to the cloned sequence. Chain extension in the presence of the competing dideoxynucleotide results in the random incorporation of that nucleotide at the appropriate sites in the extended product. The mixture of labelled chain-terminated products are fractionated according to size by electrophoresis on a denaturing acrylamide gel and the ladder of products revealed by autoradiography. Fig. 4.12. Principle of the dideoxynucleotide chain-termination procedure. Primer ( ) is annealed to the single-stranded template at a site adjacent to the cloned sequence. Chain extension in the presence of the competing dideoxynucleotide results in the random incorporation of that nucleotide at the appropriate sites in the extended product. The mixture of labelled chain-terminated products are fractionated according to size by electrophoresis on a denaturing acrylamide gel and the ladder of products revealed by autoradiography.
Row sheet for sequencing by the M13 cloning-dideoxy chain termination procedure. [Pg.162]

In the dideoxy chain-termination procedure all the bands produced on the sequencing gel should ideally result from specific chain termination caused by the incorporation of a dideoxynucleo-tide. However, spurious chain termination can also occur and while the reasons for this are not altogether clear, it is supposed that this... [Pg.201]

A method for sequencing single stranded cloned DNA in both directions by the dideoxynucleotide-chain termination procedure (Hong, G.F., Bioscience Reports 1, 243-252 (1981)... [Pg.289]

Only carried out as a terminal procedure under general anaesthesia. [Pg.926]

A Hazardous Materials Technician can take more aggressive action toward hazardous materials incidents than an operations level first responder. They can plug, patch, and stop a release. Their training is of at least 24 h, equal to that of the first responder at the operation level in addition, the technician must have competency and the employer shall certify that competency in the following areas (1) function of the Incident Command System (ICS) (2) proper PPE selection (3) hazard and risk assessment techniques (4) advanced control, containment, and confinement operations (5) decontamination procedures - or lack of decontamination (6) termination procedures and... [Pg.971]

Hazard and risk assessment, personal protective equipment, handling of releases, decontamination, operating and termination procedures leader s training guide included. [Pg.157]

The restriction fragments can be sequenced using a chain-terminator procedure developed by Frederick Sanger known as the dideoxy method. This method involves generating fragments whose length depends on the last base added to the fragment. Because of its simplicity, it has superceded alternative methods. [Pg.1134]

In the future, there may be greater utilization of cerebrospinal fluid and techniques such as proteomics and metabonomics (Ohta and Ohta 2002 van den Heuvel et al. 2003 Sukuzi et al. 2005). Collection of cerebrospinal fluid (CSF) is an invasive procedure generally reserved for terminal procedures. However, it is not commonly used in toxicology, and species differences in the blood-brain barriers are not well documented. [Pg.249]

An imderstanding of the relevant standard operating procedures and termination procedures. [Pg.245]

This series converges much faster than the Fourier series employed in calculations of the electron density distributions [3-5], However, in view of the limited number of x-ray reflections, the present series cannot be computed by the usual summation method without committing an error in the termination procedure... [Pg.101]


See other pages where Termination procedures is mentioned: [Pg.3]    [Pg.4]    [Pg.255]    [Pg.759]    [Pg.115]    [Pg.174]    [Pg.167]    [Pg.1494]    [Pg.432]    [Pg.432]    [Pg.76]    [Pg.30]    [Pg.31]    [Pg.40]    [Pg.107]    [Pg.123]    [Pg.137]    [Pg.161]    [Pg.203]    [Pg.214]    [Pg.438]    [Pg.387]    [Pg.4]    [Pg.4]    [Pg.5]    [Pg.971]    [Pg.581]    [Pg.560]    [Pg.246]    [Pg.131]   
See also in sourсe #XX -- [ Pg.299 ]




SEARCH



© 2024 chempedia.info