Standard units curves

A statistical method for plotting the relative frequency (dN/N) of a probable error in a single measured value X versus the deviation (z) from fi, the mean of the data, in units of standard deviation (o-), such that z = (x -fji)/a. The standard error curve (shown below) does not depend on either the magnitude of the mean or the standard deviation of the data set. The maximum of the normal error curve is poised at zero, indicating that the mean is the most frequently observed value. [Pg.510]

The normal distribution is the curve over which students and teachers alike agonize in connection with course grades. We discuss this distribution function in greater detail in Chapter 2. For the present we are concerned only with its descriptive capabilities. For this purpose it is sufficient to note that tables are available (e.g., Beyer 1987 also see the other references at the end of this Appendix) that supply the value of this function in terms of the standard unit,... [Pg.634]

The slope of the standard addition curve is 0.018 8 absorbance units/ppm. If, instead, Sr is added to distilled water, the slope is 0.030 8 absorbance units/ppm. That is, in distilled water, the absorbance increases 0.030 8/0.018 8 = 1.64 times more than it does in aquarium water for each addition of standard Sr. We attribute the lower response in aquarium water to interference by other species that are present. The absolute value of the jc-intercept of the standard addition curve, 7.41 ppm, is a reliable measure of Sr in the aquarium. [Pg.468]

Prepare a standard calibration curve using the data obtained for standard gamma globulin (Table E4.2, tubes 2 to 6). Plot the absorbance on the j axis and mg of standard protein per assay on the x axis. Use the standard curve to calculate the protein concentration in the isolated a-lactalbumin fractions (in units of mg/mL.) Compare your graph with Figure 2.6. [Pg.275]

In wavenumbers relative to indicated laser. Standard emission curve (with maximum equal to 1.0 arbitrary units) is reconstructed from the coefficients and the Raman shifts (relative to 514.5 or 785 nm) raised to the indicated powers. From Reference 20. [Pg.277]

A variant of this method was described by Malvano et al. (1982) standard unit response curves are constructed with aliquots of a highly positive serum diluted with a negative sample. This approach is based on the assumption that dose-response curve parallellism eliminates the necessity to employ many different sera for the calibration curve. This positive serum is then calibrated against a WHO standard serum and the antibody content of the positive serum is expressed in international units (lU). Calibration samples of the positive serum diluted with a negative serum are included as internal markers for between-run, between-laboratory and between-method normalizations to provide analytical consistency to the measurements. [Pg.401]

Fig. 3). For this reason, always radiometric units must be used in photosynthesis instead of photometric units. The radiometric analogue of the lumen (luminous flux) is the watt (radiant flux). At each wavelength both are coupled according to the standard observer curve at 555 nm 1 W of radiant flux corresponds to a luminous flux of 683 lumens by definition. As a comparison, at 650 nm, 1 W corresponds to 73 lumens only. [Pg.196]

Dubinin et al. evaluated the amount surface area from the benzene isotherm measured for the nonporous reference adsorbent /7/, we, however estimated the specific surface area Sme of the mesopores from the adsorption isotherm studied /8/, In calculations of the mesopore size distribution and the specific surface area Sme it has been assumed that the parallel - sided slits are rigid and the size distribution does not extend continuously from the mesopore into both the macropore and micropore range. We have used the desorption branch of the hysteresis loop of the isotherm for the computation. The procedure of B.F. Roberts /9/ has been applied. In this computation, which is a rigorous application of the concept of simultaneous capillary condensation and multilayer adsorption, the adsorbed volume is first expressed as a function of pore size then it is converted to pore volume. A standard t - curve /lO/, which represents the benzene adsorption onto nonporous carbon blacks, has been used for correction for multilayer thickness. [Pg.492]

Figure 5-5T. Standard six-blade vertical curved blade turbine impeller. Gives good efficiency per unit of horsepower for suspensions, mixing fibrous materials. Gives high pumping capacity. Courtesy of Philadelphia Gear Corp. Figure 5-5T. Standard six-blade vertical curved blade turbine impeller. Gives good efficiency per unit of horsepower for suspensions, mixing fibrous materials. Gives high pumping capacity. Courtesy of Philadelphia Gear Corp.
An increase in steam pressure over design will not increase vapor handling capacity for the usual fixed capacity ejector. The increased pressure usually decreases capacity due to the extra steam in the diffuser. The best ejector steam economy is attained when the steam nozzle and diffuser are proportioned for a specified performance [8]. This is the reason it is difficult to keep so-called standard ejectors in stock and expect to have the equivalent of a custom designed unit. The throttling type ejector has a family of performance curves depending upon the motive steam pressure. This type has a lower compression ratio across the ejector than the fixed-type. The fixed-type unit is of the most concern in this presentation. [Pg.353]

It follows from equation 1.14 that for any constant ratio of a /a the E vs. pH relationship will be linear with a slope -0-059m/z, and that when = 1 fhe intercept of the curve on the E axis (i.e. pH= 0) will be E, the standard equilibrium potential, which by definition is the potential when the species involved in the equilibrium are at unit activity. [Pg.65]

FIGURE 11.23 Power analysis.The desired difference is >2 standard deviation units (X, - / = 8). The sample distribution in panel a is wide and only 67% of the distribution values are > 8. Therefore, with an experimental design that yields the sample distribution shown in panel a will have a power of 67% to attain the desired endpoint. In contrast, the sample distribution shown in panel b is much less broad and 97% of the area under the distribution curve is >8. Therefore, an experimental design yielding the sample distribution shown in panel B will gave a much higher power (97%) to attain the desired end point. One way to decrease the broadness of sample distributions is to increase the sample size. [Pg.253]

Curve Equilibrium Standard value, (E° s) (V) pH dependence (V / pH unit)... [Pg.159]

Figure 5-5S. Four-blade, vertical Figure 5-5T. Standard six-blade fiat blade turbine Impeller. Very vertical curved blade turbine versatile, one of the most used impeller. Gives good efficiency in wide application range. Cour- per unit of horsepower for sus-tesy of Philadelphia Gear Corp. pensions, mixing fibrous materials. Gives high pumping capacity. Courtesy of Philadelphia Gear Corp. Figure 5-5S. Four-blade, vertical Figure 5-5T. Standard six-blade fiat blade turbine Impeller. Very vertical curved blade turbine versatile, one of the most used impeller. Gives good efficiency in wide application range. Cour- per unit of horsepower for sus-tesy of Philadelphia Gear Corp. pensions, mixing fibrous materials. Gives high pumping capacity. Courtesy of Philadelphia Gear Corp.
Wittwer and Zollinger (1954) determined the neutralization curves of aqueous solutions of diazonium salts under standard conditions of ionic strength, etc., and found that the acidity depended on the degree of neutralization in a manner different to that expected for a dibasic acid. The curve obtained did not exhibit two steps with an intermediate region of a few pH units in which the monobasic acid is stable, as is the case, for instance, with oxalic acid (Fig. 5-1). On the contrary, there was only one step, but it extended over two equivalents of base per diazonium ion. [Pg.90]

Figure 1.17. The 95% confidence intervals for v and Xmean are depicted. The curves were plotted using the approximations given in Section 5.1.2 the /-axis was logarithmically transformed for a better overview. Note that solid curves are plotted as if the number of degrees of freedom could assume any positive value this was done to show the trend / is always a positive integer. The ordinates are scaled in units of the standard deviation. Figure 1.17. The 95% confidence intervals for v and Xmean are depicted. The curves were plotted using the approximations given in Section 5.1.2 the /-axis was logarithmically transformed for a better overview. Note that solid curves are plotted as if the number of degrees of freedom could assume any positive value this was done to show the trend / is always a positive integer. The ordinates are scaled in units of the standard deviation.
These data can then be fed into electronic medical records (EMR) such as those the NHS plans to introduce throughout the UK over the next 2 years. This represents a process that will ultimately both reduce the frequency with which patients have to visit their doctor and improve health care delivery. EMR or electronic personal health records (as they are also known) have already been established, or are being established, in many European nations, such as Denmark. The United States, with its decentralized health care industry, is behind the curve in these efforts. However, in early fall of 2005, IBM and eight other IT companies that form the Technology CEO Council (TCC), including Intel, HP, Dell, Motorola, EMC, Applied Materials, NCR, and Unisys committed to adopt electronic health records based on open standards. In addition to these private sector efforts, the US Department of... [Pg.769]


See other pages where Standard units curves is mentioned: [Pg.226]    [Pg.253]    [Pg.224]    [Pg.88]    [Pg.274]    [Pg.400]    [Pg.391]    [Pg.79]    [Pg.443]    [Pg.444]    [Pg.111]    [Pg.290]    [Pg.545]    [Pg.316]    [Pg.323]    [Pg.513]    [Pg.822]    [Pg.1051]    [Pg.134]    [Pg.528]    [Pg.17]    [Pg.226]    [Pg.164]    [Pg.452]    [Pg.196]    [Pg.81]    [Pg.388]    [Pg.399]   
See also in sourсe #XX -- [ Pg.400 ]




SEARCH



Expression of dose-response curves in standard units

Standard curve

Standardization curve

Standardized units

Units standard