Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Standard minute value

Step 3 List all motions sequentially. Refer to the synthetic data for time measuring unit (TMU) values. For synthetic data one can refer to GSD (without license use of GSD code prohibited but for personal use and study one can refer to GSD code and TMU values) or sewing performance data (SPD) table. Now one can obtain a TMU value for one operation (for example, say it is 400 TMU). Convert total TMU into minutes (1 TMU = 0.0006 min). This is called as basic time in minutes. In this example it is 0.24 min (i.e. 400 x 0.0006 min). Step 4 SAM = (basic minute - - bundle allowances -I- machine and personal allowances). Add bundle allowances (10%) and machine and personal allowances (20%) to basic time. Now one can obtain standard minute value (SMV) or SAM. SAM = (0.24 -I- 0.024 - -0.048) = 0.312 min. [Pg.91]

Figure 9 Effect of cyclosporin A on the brain (A) and plasma (B) concentration of nC verapamil in healthy volunteers. (A) 1 -Verapamil ( 0.2 mCi/kg) was administered to healthy volunteers intravenously, approximately one minute before and after one-hour infusion of cyclosporin A (2.5 mg/kg/h). (B) PET images of a normal human brain after nC-verapamil administration in the absence or presence of cyclosporin A. Images shown are in SUV summed over a period of 5 to 25 minutes, which is an index of regional radioactivity uptake normalized to the administered dose and weight of the subject. Abbreviations PET, positron emission tomography SUV, standardized uptake value. Source From Ref. 218. Figure 9 Effect of cyclosporin A on the brain (A) and plasma (B) concentration of nC verapamil in healthy volunteers. (A) 1 -Verapamil ( 0.2 mCi/kg) was administered to healthy volunteers intravenously, approximately one minute before and after one-hour infusion of cyclosporin A (2.5 mg/kg/h). (B) PET images of a normal human brain after nC-verapamil administration in the absence or presence of cyclosporin A. Images shown are in SUV summed over a period of 5 to 25 minutes, which is an index of regional radioactivity uptake normalized to the administered dose and weight of the subject. Abbreviations PET, positron emission tomography SUV, standardized uptake value. Source From Ref. 218.
Use the data from the measurements of the solutions of standards and unknown to calculate the following for each, with standard deviation. The instructor will provide the beta-particle values in disintegration per minute values for the standard sources. [Pg.20]

Blood and urine are most often analyzed for alcohol by headspace gas chromatography (qv) using an internal standard, eg, 1-propanol. Assays are straightforward and lend themselves to automation (see Automated instrumentation). Urine samples are collected as a voided specimen, ie, subjects must void their bladders, wait about 20 minutes, and then provide the urine sample. Voided urine samples provide the most accurate deterrnination of blood alcohol concentrations. Voided urine alcohol concentrations are divided by a factor of 1.3 to determine the equivalent blood alcohol concentration. The 1.3 value is used because urine has approximately one-third more water in it than blood and, at equiUbrium, there is about one-third more alcohol in the urine as in the blood. [Pg.486]

Because pulp bleaching agents are, for the most part, reactive oxidising agents, appropriate precautions must be taken in their handling and use. For example, it is important to ensure that the threshold limit values (TLV) (20) in Table 2 are not exceeded in the workplace air. These are airborne concentrations in either parts per million by volume under standard ambient conditions or mg per cubic meter of air. They "represent conditions under which it is beUeved that nearly all workers may be repeatedly exposed, day after day, without adverse effect" (20). TWA refers to a time-weighted average for an 8-h workday STEL is a short-term exposure limit or maximum allowable concentration to which workers can be continuously exposed for 15 minutes. [Pg.158]

For non-effectively grounded systems, having a GFF of more than 1.4, a higher level of insulation (BIL) will be essential for all equipment being used on the system to withstand a higher level of a one-minute power frequency voltage test as well as an impulse voltage withstand test if such levels (Lists I, II and III) are prescribed in the relevant standards. If not, then it may be assumed, that the prescribed test values take account of such an... [Pg.667]

A common method of stating flow is standard cubic feet per minute where the flowing conditions are referred to an arbitrary set of standard conditions. Unfortunately, standard conditions are anything but standard. Of the many used, two are more common. The ASME standard uses 68°F and 14.7 psia. The relative humidity is given as 36%. The other standard that is used by the gas transmission industry and the API Mechanical Equipment Standards is 60°F at 14.7 psia. As can be seen from this short discussion, a flow value must be carefully evaluated before it can be used in a compressor calculation. [Pg.21]

The vibration characteristics, determined by use of the instrumentation, will serve as the basis for acceptance or rejection of the machine. API standards generally require that the equipment be operated at speed increments of approximately 10% from zero to the maximum continuous speed and run at the maximum continuous speed until bearings, lube-oil temperatures, and shaft vibrations have stabilized. Next, the speed should be increased to trip speed and the equipment run for a minimum of 15 minutes. Finally, the speed should be reduced to the maximum continuous speed and the equipment should be run for four hours. API does not require that the four hours be uninterrupted however, it is generally interpreted that way. The interpretation is one of the many test criteria to be discussed. It would seem that a break in the test at the midpoint is not the same as having it cut short five minutes from the end because the vendor s boiler took an upset that was not related to the compressor test. The ibration during the shop test is normally specified as the API limit of 1.0 mils peak to peak, or the value from Equation 10.1, unfiltcred. whichever is lower. [Pg.410]

To determine the cubic feet per minute of compressed air at any temperature and pressure other than standard conditions, multiply the value of cubic feet per minute of free air by the ratio ... [Pg.106]

Therrtial Sterilization of Pouches of Beef. Methodology for food thermoprocessing in cylindrical metal containers assured food sterility in flexible packages. Beef slices (1.25 cm thick) were steam cooked to an internal temperature of 72°C and vacuum sealed in pouches to give a fill of 120 g. These pouches of beef were processed in a standard retort with complete water circulation and a superimposed air pressure of 1.7 X 105 Pa. The retort schedule—a 40-minute cook at 118°C plus come-up time followed by a 30-minute cooling time—achieved a F0 (lethality value) of 6. [Pg.96]

Determination of the porosity of a tablet presents the classic problem of defining the appropriate volume to be measured. The displacement medium may be able to penetrate the most minute crevices, as is the case for helium. Other displacement media, such as mercury, are unable to enter the smallest tablet crevices and thus produce different porosity values. Standardization of displacement media is therefore necessary for comparative evaluations. [Pg.332]

Lineweaver and Ballou49 have proposed a pectinesterase unit ( PE. u. ) for expressing PM activity. One such unit is equivalent to 1/930 PMU under the same experimental conditions or the quantity of enzyme that, at 30° and optimum pH, will catalyze the hydrolysis of pectin at an initial rate of one milliequivalent ester bonds per minute in a standard substrate (0.5% citrus pectin containing 8-11% methoxyl) and 0.15 M sodium chloride. The use of the latter unit is unfortunate since the values obtained for the activity in ordinary plant materials are obtained in the third decimal place and because the experimental conditions are so... [Pg.107]

THC levels, drawn at hourly intervals starting 20 minutes after smoking, were highly variable, as shown by the large standard deviation (which appears quite small when plotted on a logarithmic y-axis). The actual range of all THC values was from 3 to 220 ng/ml (no doubt reflecting major differences in the rate and depth of... [Pg.337]


See other pages where Standard minute value is mentioned: [Pg.91]    [Pg.91]    [Pg.350]    [Pg.76]    [Pg.29]    [Pg.29]    [Pg.197]    [Pg.395]    [Pg.390]    [Pg.403]    [Pg.188]    [Pg.265]    [Pg.166]    [Pg.173]    [Pg.343]    [Pg.726]    [Pg.119]    [Pg.415]    [Pg.391]    [Pg.305]    [Pg.236]    [Pg.93]    [Pg.219]    [Pg.24]    [Pg.379]    [Pg.34]    [Pg.212]    [Pg.145]    [Pg.171]    [Pg.208]    [Pg.322]    [Pg.241]    [Pg.146]    [Pg.161]    [Pg.282]    [Pg.192]   
See also in sourсe #XX -- [ Pg.91 ]




SEARCH



Minute

Standard value

© 2024 chempedia.info