Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Specimen mounting

The specimen chamber (or target chamber) may contain a number of samples and standard specimens mounted on the same sample holder. Also here are the X-ray detection system and a Faraday cup which monitors the proton current incident... [Pg.98]

Figure 15. Detail of the bottom of the Avesta cell. Crevice corrosion is avoided by a small flow of distilled water through the pores of filter paper at the crevice at the specimen/mounting interface. I. specimen. 2. O-ring. 3. Filter paper ring. Figure 15. Detail of the bottom of the Avesta cell. Crevice corrosion is avoided by a small flow of distilled water through the pores of filter paper at the crevice at the specimen/mounting interface. I. specimen. 2. O-ring. 3. Filter paper ring.
Samples of microspheres were mounted on aluminum specimen mounts by means of double-faced tapes. The microspheres were fractured with razor blades to expose the internal matrix. The samples were then coated with approximately 125 of gold by pulsing the sputter coater to avoid the possibility of artifact caused by heat generation. Secondary emissive scanning electron microscopy was performed with an Amray 1600 Turbo scanning electron microscope. [Pg.216]

In this test a failing weighted pendulum strikes a rectangular bar specimen, mounted vertically by being clamped at the lower end the specimen is usually notched, the notch dimensions being specified. Commonly used standard conditions are ... [Pg.829]

The analysis chamber was equipped with diffusion and Ti-sublimation pumps and had a base pressure of 1x10 mbar It was also equipped with an RGA identical to the one on the preparation chamber. In this chamber the specimen could be analyzed by XPS and heated by a resistive element Incorporated in the specimen mount. [Pg.224]

Scanning electron micrographs were obtained on a Cambride Mark II Stereoscan SEM. The samples were mounted on the specimen mounts with double-sided tape. Silver paint along the edge of the sample provided electrical contact between the specimen mount and... [Pg.408]

Environmental Chamber The samples were aged in an environmental exposure chamber (Tenney model BTRS) which is capable of operating and maintaining (up to several months) a hot, humid atmosphere which can be varied to 100 C while the relative humidity can be varied from 20 to 98% (for temperatures up to 85 °C). The internal dimensions of the chamber are 0.5 x 0.5 x 0.5 m permitting the simultaneous aging of many specimens mounted in stress rigs. [Pg.123]

To examine the nanowires using SEM, place a drop of nanowires suspended in water directly on an aluminum SEM specimen mount and allow the drop to dry. (To obtain a smoother background in the images, attach a piece of silicon to the specimen mount using carbon tape and place the drop of nanowire suspension on the silicon.) No conductive coating needs to be added. We imaged... [Pg.468]

Consideration is given to (a) possible edge effects, (b) the method of specimen mounting, (c) the problem of illumination and viewing, and (d) possible interactions (Bowman Bevis, 1977). [Pg.19]

Figure 11.25. Raman microspectroscopy of a human tissue slice from a prostate cancer biopsy specimen mounted in paraffin. Scale on video image is in microns. Figure 11.25. Raman microspectroscopy of a human tissue slice from a prostate cancer biopsy specimen mounted in paraffin. Scale on video image is in microns.
Fig. 7. Atomic force microscope image of the acquired pellicle layer formed on an enamel specimen mounted at the palatal site of the upper first molar and exposed to the oral environment for 10 min. The pellicle surface is characterised by a densely packed layer of globularly shaped particles of 15-30 nm diameter. [Pg.43]

Diffraction by substances other than the unknown. Such substances are usually impurities in the specimen but may also include the specimen mount or badly... [Pg.326]

Figure 13 shows the set-up used for a corrosion study at high acid levels, with specimens mounted in a chamber in a vertical downflow reactor configuration. The chamber was nominally divided into five equal-length zones, with each zone being defined by the presence of a thermocouple. Oxidation of organic... [Pg.432]

Figure 4. Stone specimen mounted in shaping machine for surface sampling. Tungsten carbide tool bit reciprocating horizontally precisely removes layers of stone, producing powders for chemical analysis. Figure 4. Stone specimen mounted in shaping machine for surface sampling. Tungsten carbide tool bit reciprocating horizontally precisely removes layers of stone, producing powders for chemical analysis.
Specimen mounting solution Add 1 part of PI staining solution to 9 parts of glycerol. [Pg.44]

A = Capillary inlet B = Power coil C = Specimen mounting tube D = Sidearm to manometer and E r= Outlet to vacuum pump... [Pg.241]

Taber Abrasion Resistance - The weight loss of a plastic or other material specimen after it was subjected to abrasion in a Taber abraser for a prescribed number of specimen disk rotations, usually 1000. A Taber abraser consists of an idling abrasive wheel, designated depending on the type and grit of abrasive used as CS-lOF, H 22, etc., and a rotary disk with the specimen mounted on it. The load is applied to the wheel. The produced motion simulates that of rolling with slip. [Pg.544]


See other pages where Specimen mounting is mentioned: [Pg.1345]    [Pg.146]    [Pg.29]    [Pg.155]    [Pg.385]    [Pg.89]    [Pg.60]    [Pg.357]    [Pg.728]    [Pg.95]    [Pg.103]    [Pg.465]    [Pg.147]    [Pg.345]    [Pg.20]    [Pg.31]    [Pg.142]    [Pg.176]    [Pg.68]    [Pg.319]    [Pg.497]    [Pg.66]    [Pg.482]    [Pg.242]    [Pg.34]    [Pg.364]   
See also in sourсe #XX -- [ Pg.95 ]




SEARCH



Mount

© 2024 chempedia.info