Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Signal modifiers

The recognition of the importance of MP in maintaining the health of the retina has led to the development of a number of methods for determining its concentration in situ. These methods, necessarily noninvasive, are routinely employed in dietary supplementation studies with lutein or zeaxanthin to monitor the uptake of the carotenoids into the retina. Every method exploits the optical properties of lutein and zeaxanthin, specifically their absorbance at visible wavelengths. The detection of a light signal, modified by the carotenoids, is accomplished either by the retinal photoreceptors themselves (psychophysical methods) or by a physical detector such as a photomultiplier,... [Pg.75]

Reversibility is also an issue if the sensor is to be used more than once which, given the investment necessary to synthesize any complex molecule, will be highly desirable. The sensor s solubility in aqueous or organic solvents must be considered. Most targets are likely to be in water so fluorescent and optical sensors will need to be water soluble. Other sensors may be surface bound, or incorporated into other materials as signal modifiers, in which case aqueous solubility is not an issue. [Pg.187]

All proportional detectors are designed to provide a response that is as close to linear as possible in order to facilitate calculation procedures in quantitative analysis. In many detectors the output from the detector sensor is not linearly elated to the solute concentration, in which case appropriate signal modifying circuits must be used to furnish a linear output. For example the output from a light adsorption sensor will be exponential and consequently it must be used with a logarithmic amplifier to produce an output that is linearly related to solute concentration. [Pg.19]

Any inherent non-linearity of the sensor can be corrected by an appropriate signal modifying amplifier. An example of the use of the detector to analyze a sample of helium is shown in figure 10. The high sensitivity of the detector to traces of the permanent gases is clearly demonstrated. [Pg.135]

The detector was claimed to be moderately linear over a dynamic range of three orders of magnitude but values for the response index are not known. It is also not clear whether the associated electronics contained signal modifying circuitry or not. The disadvantages of this detector included erosion of the electrodes due to "spluttering", contamination of the electrodes from sample decomposition and the need for a well-controlled vacuum system. [Pg.162]

The electronic system of the electrical conductivity detector is comprised of a 1 kHz frequency generator, the output of which is fed via a suitable impedance to the detector electrodes. The voltage across the electrodes is fed to a precision rectifier to provide a DC signal that is related to the conductivity of the fluid between the sensor plates. The DC signal is then passed to a signal modifying amplifier to... [Pg.281]

As an example, for a UV-Vis spectrophotometer, the signal generator is the radiation source, the input transducer is the photodetector, the electronic signal modifier is a current-to-voltage converter and the output transducer is the digital display. [Pg.4]

The critical role of carbohydrate recognition in cellular functioning has impelled aggressive research directed toward the understanding and control of the intermolecular processes involved in carbohydrate metabolism and signaling. Modified saccharide structures incorporating /V-thiocarbonyl... [Pg.102]

Chen, T, Bai, H Shao, Y, Arzigian, M Janzen, V., Attar, E., Xie, Y, Scadden, D.T., and Wang, Z.Z. (2007) Stromal cell-derived factor-l/CXCR4 signaling modifies the capillary-like organization of human embryonic stem cell-derived endotheliiun in vitro. Stem Cells (Dayton, Ohio), 25, 392-401. [Pg.265]

Thermoresistive Flow Sensors, Fig. 4 Flow measurement by time-of-flight principle, (a) Sensor configuration (b) sensor signal (Modified from [V, 9])... [Pg.3315]

A third class of synthesis units comprises signal modifiers such as low- and high-pass filters (more about filters in Chapter 4). [Pg.16]

In order to introduce some variance over time, wavecycle oscillators should be used in conjunction with signal modifiers such as envelopes and low-frequency oscillators (LFO). [Pg.45]


See other pages where Signal modifiers is mentioned: [Pg.214]    [Pg.545]    [Pg.195]    [Pg.180]    [Pg.184]    [Pg.281]    [Pg.777]    [Pg.130]    [Pg.75]    [Pg.17]    [Pg.8]    [Pg.4]    [Pg.267]    [Pg.1060]    [Pg.2164]    [Pg.705]    [Pg.111]    [Pg.118]   
See also in sourсe #XX -- [ Pg.16 ]




SEARCH



© 2024 chempedia.info