Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

5 sigma width

Metrics for this might include number of excursions from statistical process control, but one very useful metric for controllability is process capability, or more accurately, process capability indices. Process capability compares the output of an in-control process to the specification limits by using capability indices. The comparison is made by forming the ratio of the spread between the process specifications (the specification width ) to the spread of the process values. In a six-sigma environment, this is measured by six standard deviation units for the process (the process width ). A process under control is one where almost all the measurements fall inside the specification limits. The general formula for process capability index is ... [Pg.238]

FIGURE 9.1 Linewidth versus standard deviation. A gaussian distribution of unit amplitude is plotted on an x-axis scale in units of the standard deviation (or sigma). At 3.15x0 the unit intensity has dropped to 0.1%. The linewidth in simulations is usually expressed as the halfwidth at half height (HWHH), which is equal to circa 1.17x0, or as twice this value that is, the full width at half height (FWHH). [Pg.154]

FIGURE i 6 Diagram indicating that the total variance in the analysis results equals the sum of the method variance and the process variance. A capable measurement system has a method variance that is less than 30% of the design width (difference between upper specification level and lower specification level). The production process is considered to be under full control when the average assay value is centered at Six Sigma values away from the lower and upper specification levels. [Pg.180]

Match the main features of the rocking curve first, using plane wave calculations and a single (sigma) polarisation. It shonld be possible to fit all the main peaks accnrately in spacing and approximately in intensity. Then begin refinement to match the intensities and widths. [Pg.123]

Dialysis tubing (from Sigma Cat. No. D9652), flat width 33 mm, diameter 21 mm, cellulose (retains > 90% cytochrome c, MM 12.4 kDa, in solution over a 10 h period supplied in rolls, dry may contain glycerol and sulfur compounds in more than trace amounts washing instructions supplied). [Pg.24]

Correlations of with Other Properties. With this introduction to the measurement of we shall examine the important relationships which have been found between the physical properties of H bonded systems and the shift of brought about by the H bond interaction. Some of these relationships are summarized qualitatively in Fig. 3-6. These values of Av refer to a variety of systems, each with a well defined H bonded molecular species (in contrast to the Avs data of Fig. 3-5, which refer to the superposition of absorptions of many different polymeric species of a single type of AB molecules). In Fig. 3-6 we see that Av is inversely related to the A 3 distance (/ ), and Hammett sigma function, whereas it is directly related to enthalpy of H bond formation, the A—H distance (r), and the two IR spectral properties, half-width and intensity. [Pg.82]

The position, extinction coefficients and band half-widths of anilines and of polycyclic aromatic amines were studied by infrared spectroscopic measurements a long time ago34. One purpose was to understand the hybridization of the nitrogen atom bonded to unsaturated systems35,36. Infrared spectroscopic parameters of the NH2 group in substituted anilines were correlated with the Hammett sigma substituent constants37. [Pg.411]

Agarose (e.g. Sepharose CL-4B(r), Sigma) column of adequate length and width 30 cm length and 1 cm width) for size exclusion chromatography (SEC). Store hydrated with isotonic HEPES buffer at 4°C. [Pg.548]

Gold-coated cover slip. (Sigma-Aldrich, 99.999% (Au), layer thickness 100 A, length x width x thickness 22 mm x 22 mm x 160 pm, Catalog Number 643254). [Pg.75]

Detection of hydroxyl radical. For detection of hydroxyl radicals, a spin trapping agent, DMPO was obtained from Sigma-Aldrich.4 The water containing 500 pM DMPO was circulated for 30 min in exPCAW-l,and the water was sampled at 0, 1, 5, 10, 15, 20, 30 min of circulation and exposure to UV, USW and elevated 02. The samples in a flat-shaped quartz ESR cell were analyzed with an electron spin resonance spectrometer (JEOL-TE200, X-band). DMPO-OH signal were collected with a sweep width of 5 mM, a 100 kHz modulation frequency, 60 s sweep time, a time constant of 0.1 s and microwave power of 10 mW, at room temperature of 20-25°C. [Pg.226]

The standard deviation, a, commonly called sigma, parametrizes the half-width of the distribution. It is defined as the root mean square of the distribution. The mean square is given by... [Pg.105]

In the 15 keV - 10 MeV region, line-forming processes such as nuclear excitation, radioactivity, positron annihilation, cyclotron emission and absorption become important, and when used as astrophysical tools, are almost certain to lead to fundamental new discoveries. Unique astrophysical information is contained in the spectral shift, line width, and line profiles. Detailed studies of these processes require the resolving power (E/AE = 500) of a Germanium spectrometer such as that employed on INTEGRAL. Lower resolution spectrometers (e.g. SIGMA, OSSE, COMPTEL) do not have sufficient energy resolution to study the parameters of these lines. The... [Pg.71]

A further procedure using five standard deviations (the five sigma method, can also be used as a measure of column efficiency. This measures the width of the peak at 4.4% of peak height (1V4 4) and has the advantage of giving a better indication of undesirable tailing effects (see Figure 1.1). The plate number is calculated from eqn (1.5), but the measured efficiencies will inevitably be lower then the 4 values usually encountered. [Pg.5]

Fig. 8.18 Results of the address level calibration [13]. Left RMS of width of the six address level peaks for all operable ROCs in the detector. Right Separation between the mean of two neighboring peaks. The separation is given in units of sigma, defined by summing in quadrature the RMS widths for adjacent peaks... Fig. 8.18 Results of the address level calibration [13]. Left RMS of width of the six address level peaks for all operable ROCs in the detector. Right Separation between the mean of two neighboring peaks. The separation is given in units of sigma, defined by summing in quadrature the RMS widths for adjacent peaks...
Modulation-based readout circuits have gained popularity for interfacing with capacitive and inductive MEMS sensors to reduce the noise levels of l// noise and direct current (dc) offset in the circuit. Modulation-based circuits are based on sigma-delta (2A) converter [56,62,65], successive approximation register (SAR) analog-to-digital converter (ADC) [56,66], chopper modulation [54,55,58], pulse-width modulation (PWM) [57,61,63], and frequency modulation (FM) configurations [42,48,51,64,68],... [Pg.158]

Width of a chromatographic peak measured either on the projected baseline (w) or at 60% height (also called 2 times sigma). [Pg.71]


See other pages where 5 sigma width is mentioned: [Pg.32]    [Pg.70]    [Pg.176]    [Pg.364]    [Pg.364]    [Pg.365]    [Pg.367]    [Pg.78]    [Pg.32]    [Pg.217]    [Pg.58]    [Pg.567]    [Pg.13]    [Pg.266]    [Pg.320]    [Pg.16]    [Pg.824]    [Pg.824]    [Pg.43]    [Pg.674]    [Pg.114]    [Pg.18]    [Pg.547]    [Pg.93]    [Pg.104]    [Pg.128]    [Pg.179]    [Pg.76]    [Pg.139]    [Pg.243]    [Pg.127]   
See also in sourсe #XX -- [ Pg.49 ]




SEARCH



Sigma

© 2024 chempedia.info