In HPLC-TLC coupling, the crucial aspect is the maintenance of the chromatographic integrity during the deposition process. The chromatogram is preserved after LC separation, and is available for further separation and/or investigation. LC-TLC coupling increases the separation efficiency, and allows detection modes which are incompatible with LC (e.g. spectroscopic techniques... [Pg.554]

Integrating liquid-liquid extraction and detection is far from easy, as reflected in the few attempts made so far. Many of the devices developed for this purpose fail to comply with the definition of sensor. Such is the case with continuous liquid-liquid extraction systems without phase separation, where programmed switching of the propulsion system (a peristaltic pump) allows the extracting phase to be passed iteratively by the detection point in a back-and-forth motion that enriches it gradually with the extracted species [9-11]. This type of system is much too Complex to be considered a sensor, though in addition, the extraction process is not completely simultaneous with detection. [Pg.211]

Therefore, this sensor integrates a biochemical and a chemical reaction with a prior separation (dialysis) and chemiluminescence detection. The process involves the following steps (a) dialysis of the enzyme (6) enzymatic oxidation of the reagent (c) derivatization of hydrogen peroxide and d) detection of the chemiluminescence produced. Such an original approach offers several advantages over similar methodologies, namely ... [Pg.280]

For MS detection, the microfluidic chip has been coupled to various ionization interfaces (ESI, MALDI) and to different mass analyzers (by single quadrupole, triple Q, ion-trap, MS/MS, and FTICR). The chip can be single- or multi-channel, and can be integrated with various sample handling processes such as preconcentration, digestion, and separation. The following two sections describe the two ionization interfaces (ESI and MALDI) that precede the MS analysis. [Pg.224]

By retaining the pervaporated species in the detection zone, the previous two steps can be integrated and the kinetics of the separation process monitored as the volatile species will reach the detector at the same rate as they cross the membrane (Fig. 4.21C). Obviously, this approach is only viable with non-destructive detectors. Both approaches (Figs 4.2IB and 4.21C) allow fresh portions of the acceptor fluid to be brought into contact with the membrane in such a way that equilibrium of the separation process is never reached. [Pg.139]

This dielectrophoresis backgroxmd only serves as a brief overview these technologies need to be explored in more detail before incorporating them into a Lab-on-a-Chip system. Lab-on-a-Qiip systems integrate techniques of small fluid and sample handling with detection or process capabilities. Dielectrophoresis can be incorporated into these systems to manipulate, separate, or trap cells as well as control small amoxmts of fluid. This technology can be used to trap cells for additional analysis, separate cell types based on dielectric properties, dispense picoliter droplets, or used for similar manipulative applications. [Pg.5]

Fast analysis of ofloxacin and lidocaine (as bactericide and analgesic) is of clinic importance for understanding the patient s medical process. A sensitive method for the determination of lidocaine, ofloxacin [46], enrolloxacin (ENR), and ciprofloxacin (CIP) [47] by CE integrated with ECL detection has been developed based on porous etched joint and end-column Ru(bpy)3 ECL and successfully applied to determine ENR and CIP in milk with a solid-phase extraction procedure. The proposed method explores detection limits of lidocaine, ofloxacin, enrofloxacin, and ciprofloxacin as 3.0 x 10 , 5.0 x 10 , 10 x 10 , and 15 x 10 mol L respectively (S/N = 3). CE-ECL detection method has also been used to characterize disopyramide with a detection limit of 2.5 x 10 mol L (S/N = 3) [48], and procaine hydrolysis as a probe for butyrylcholinesterase by in vitro procaine metabolism in plasma with butyrylcholinesterase acting as bioscavenger. Procaine and its metabolite N, A-diethylethanolamine were separated at 16 kV with... [Pg.127]

The SIS is a part of instrumentation and control system which when detects that the process is out of control and there could he possibilities of hazards, it automatically returns the process to a safe state. It could be the last line - or near last line - of defense against a process hazard. Normally it is better to keep it out of BPCS and treat separately. However, there could be cases where these may be integrated with BPCS also (let the discussions start with separate SIS). The last line or near last line of defense is what differentiates an SIS from the BPCS, which is used for normal regulatory process control. Fig. VII/1.1.2-1 shows the relationship between BPCS and SIS with respect to the process. [Pg.474]

Sample preparation, injection, calibration, and data collection, must be automated for process analysis. Methods used for flow injection analysis (FLA) are also useful for reliable sampling for process LC systems.1 Dynamic dilution is a technique that is used extensively in FIA.13 In this technique, sample from a loop or slot of a valve is diluted as it is transferred to a HPLC injection valve for analysis. As the diluted sample plug passes through the HPLC valve it is switched and the sample is injected onto the HPLC column for separation. The sample transfer time typically is determined with a refractive index detector and valve switching, which can be controlled by an integrator or computer. The transfer time is very reproducible. Calibration is typically done by external standardization using normalization by response factor. Internal standardization has also been used. To detect upsets or for process optimization, absolute numbers are not always needed. An alternative to... [Pg.76]


See other pages where Separation processes integrated with detection is mentioned: [Pg.57]    [Pg.143]    [Pg.274]    [Pg.1336]    [Pg.140]    [Pg.385]    [Pg.121]    [Pg.10]    [Pg.53]    [Pg.287]    [Pg.94]    [Pg.266]    [Pg.291]    [Pg.1674]    [Pg.292]    [Pg.252]    [Pg.114]    [Pg.704]    [Pg.782]    [Pg.372]    [Pg.1052]    [Pg.1081]    [Pg.1567]    [Pg.865]    [Pg.907]    [Pg.2378]    [Pg.89]    [Pg.517]    [Pg.1602]    [Pg.4]    [Pg.945]    [Pg.964]    [Pg.1221]    [Pg.1231]    [Pg.1855]    [Pg.445]    [Pg.765]    [Pg.446]    [Pg.234]    [Pg.499]    [Pg.51]   


SEARCH



Detection integrated

Detection integrated with separation

Detection separation

Integral detection

Integrated detection-separation

Integrated processes

Integrated processing

Integration processing

Process integration

Process integrity

Processing separation

Separation processes

© 2024 chempedia.info