Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sensor-motor

Also called conformal coating. It encloses a product in a closed envelope of plastic by immersing the product (solenoids, ornament, sensors, motor components, integrated circuits, and other articles.) in an unheated or... [Pg.529]

Automated railway gate using sensors, motors, buzzer and LED. [Pg.528]

Sato H., Fuchino Y., et al.,(2005) Intersubject variability of near-infared spectroscopy signals during sensor motor contex activation, J.Biomed.Optics 10 044001.1-044001.10s... [Pg.595]

Bell, A. 2006. Sensors, motors, and tuning in the cochlea Interacting cells could form a surface acoustic wave resonator. Bioinsp. Biomim., 1(3),96-101. [Pg.420]

This section presents a case study of navigation of a mobile robot with a type of architecture sensor-motor, which fits within the reactive... [Pg.95]

Consequently, the experimental method is the development of a training course determined from a mapping sensor-motor of the robot that responds to that path. Then you must train the network to that path and verify in the operation phase that the robot learned the path, and finally, test the robot with other paths and evaluate its performance. [Pg.100]

Figure Bl.27.4. Rotating bomb isoperibole calorimeter. A, stainless steel bomb, platinum lined B, heater C, thermostat can D, thennostat iimer wall E, themiostat water G, sleeve for temperature sensor H, motor for bomb rotation J, motor for calorimeter stirrer K, coimection to cooling or heating unit for thennostat L, circulation pump. Figure Bl.27.4. Rotating bomb isoperibole calorimeter. A, stainless steel bomb, platinum lined B, heater C, thermostat can D, thennostat iimer wall E, themiostat water G, sleeve for temperature sensor H, motor for bomb rotation J, motor for calorimeter stirrer K, coimection to cooling or heating unit for thennostat L, circulation pump.
The Nametre Rotary B rotational viscometer measures torque in terms of the current needed to drive the d-c motor at a given speed while a material is under test. The standard sensors are coaxial cylinders or Brookfield disk-type spindles, but a cone—plate system is also available. The viscosity range for the coaxial cylinder sensors is 5 to 5 x 1(T mPa-s, and the maximum shear rate is 200. ... [Pg.189]

FIG. 29-8 Typical high-voltage ac motor starter illiistrating several protective schemes fuses, overload relays, ground-fault relays, and differential relays with the associated current transformer that act as fault-current sensors. In practice, the differential protection current transformers are located at the motor, hut the relays are part of the starter. [Pg.2490]

Programmable Logic Controller (PLC) A microcomputer-based solid-state control system which receives inputs from user-supplied control devices such as switches and sensors, implements them in a precise pattern determined by instructions stored in the PLC memory, and provides outputs for control or user-supplied devices such as relays and motor starters. [Pg.165]

Industrial platinum resistance thermometer sensors Effects of unbalanced voltages on the performance of 30 cage induction motors BS EN 60751/1996... [Pg.319]

Also important is the interplay between different sensors, controllers, automation equipment, and objects regulated by the control equipment. The requirements of pumps, fans, batteries, heat exchanger, valves, motors, etc. in standard sizes may greatly differ from the theoretical calculations. Because of this fact, the control equipment, in addition to satisfactory control, must be capable of correcting the differences between the calculated and delivered subproducts. [Pg.774]

Sensors TS 1-2-4 regulate the batteries for heating and cooling in a se quence to achieve the required temperatures (Fig. 9.56). Regulating valves for heat recovery are controlled by a frequency converter RCl for the pump motor. When a greater output is required from the heating battery, the pump motor speed increases before the valve MV2 opens. If the extract temperature is lower than the outdoor temperature, the speed of the pump motor increases before valve MVl opens. To avoid ice formation at low outdoor temperatures, the sensor TS7 operates on a lower limit, depending on the demands of the battery in the exhaust. [Pg.779]

Automatic roll A motor-driven continuous roll of material, either viscous or fiber, which ensures a set pressure drop in the airflow. Its operation depends on sensors that record the pressure differential on either side of the filter. [Pg.1409]


See other pages where Sensor-motor is mentioned: [Pg.802]    [Pg.308]    [Pg.508]    [Pg.308]    [Pg.10]    [Pg.308]    [Pg.149]    [Pg.259]    [Pg.23]    [Pg.9]    [Pg.802]    [Pg.308]    [Pg.508]    [Pg.308]    [Pg.10]    [Pg.308]    [Pg.149]    [Pg.259]    [Pg.23]    [Pg.9]    [Pg.800]    [Pg.802]    [Pg.199]    [Pg.429]    [Pg.165]    [Pg.23]    [Pg.187]    [Pg.407]    [Pg.121]    [Pg.108]    [Pg.127]    [Pg.134]    [Pg.135]    [Pg.292]    [Pg.305]    [Pg.339]    [Pg.477]    [Pg.598]    [Pg.55]    [Pg.547]    [Pg.550]    [Pg.255]   
See also in sourсe #XX -- [ Pg.95 , Pg.100 ]




SEARCH



Speed control motor sensors

© 2024 chempedia.info