Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Selectivity sensor arrays

FIGURE 4 J Miniaturized planar nine-site H /K selective sensor array applied to in-vivo measurements in porcine cardiovascular system. (From [107].)... [Pg.77]

In the field of chemical sensors, the revolution in software and inexpensive hardware means that not only nonlinear chemical responses can be tolerated, but incomplete selectivity to a variety of chemical species can also be handled. Arrays of imperfectly selective sensors can be used in conjunction with pattern recognition algorithms to sort out classes of chemical compounds and thek concentrations when the latter are mixed together. [Pg.389]

Explain clearly why highly selective individual electrodes are not deshed for the operation of sensor arrays. [Pg.204]

Multiple electrodes have been used to obtain selectivity in electrochemical detection. An early example involved the separation of catecholamines from human plasma using a Vydac (The Separation Group Hesperia, CA) SCX cation exchange column eluted with phosphate-EDTA.61 A sensor array using metal oxide-modified surfaces was used with flow injection to analyze multicomponent mixtures of amino acids and sugars.62 An example of the selectivity provided by a multi-electrode system is shown in Figure 2.63... [Pg.223]

In contrast to other analytical methods, ion-selective electrodes respond to an ion activity, not concentration, which makes them especially attractive for clinical applications as health disorders are usually correlated to ion activity. While most ISEs are used in vitro, the possibility to perform measurements in vivo and continuously with implanted sensors could arm a physician with a valuable diagnostic tool. In-vivo detection is still a challenge, as sensors must meet two strict requirements first, minimally perturb the in-vivo environment, which could be problematic due to injuries and inflammation often created by an implanted sensor and also due to leaching of sensing materials second, the sensor must not be susceptible to this environment, and effects of protein adsorption, cell adhesion, and extraction of lipophilic species on a sensor response must be diminished [13], Nevertheless, direct electrolyte measurements in situ in rabbit muscles and in a porcine beating heart were successfully performed with microfabricated sensor arrays [18],... [Pg.96]

Arrays were introduced in the mid-eighties as a method to counteract the cross-selectivity of gas sensors. Their use has since become a common practice in sensor applications [1], The great advantage of this technique is that once arrays are matched with proper multivariate data analysis, the use of non-selective sensors for practical applications becomes possible. Again in the eighties, Persaud and Dodds argued that such arrays has a very close connection with mammalian olfaction systems. This conjecture opened the way to the advent of electronic noses [2], a popular name for chemical sensor arrays used for qualitative analysis of complex samples. [Pg.147]

In some applications, silver/silver chloride or calomel electrodes are considered cumbersome to use and maintain. More importantly, they are extremely difficult to miniaturize particularly with regard to their combined use with potentiometric membrane electrodes (see Section 18a.4.5.4) that have been fabricated into highly miniaturized and compact screen-printed sensor arrays for clinical use. Thus, several reference electrodes are manufactured with the same polymeric materials that are needed to design the responsive ion-selective membranes [7]. Incorporation of suitable active agents into such membranes leads to potentiometric responses that are ideally independent of the sample... [Pg.631]

Puech, J.-L., Prida, A., and Isz, S. (2007). Quality assessment of oenological tannins utilising global selectivity chemical sensors array (electronic tongue). S. Afr. J. Enol. Vitic. 28(2), 101-106. [Pg.115]

For a well-behaved sensor array, only a small subset k of n available PCs is sufficient to characterize the matrix. Once again, Principal Component Regression (PCR) is a data reduction tool. The robustness of the selection of k can be tested by cross-validation in which case data subsets are randomly selected and the error matrix H xn is calculated. [Pg.323]

Formulation of the ion-selective membranes employed in the construction of the potentiometric sensor array... [Pg.739]


See other pages where Selectivity sensor arrays is mentioned: [Pg.48]    [Pg.42]    [Pg.48]    [Pg.42]    [Pg.18]    [Pg.185]    [Pg.187]    [Pg.196]    [Pg.198]    [Pg.218]    [Pg.338]    [Pg.96]    [Pg.217]    [Pg.96]    [Pg.128]    [Pg.377]    [Pg.54]    [Pg.55]    [Pg.163]    [Pg.124]    [Pg.19]    [Pg.627]    [Pg.218]    [Pg.372]    [Pg.150]    [Pg.222]    [Pg.233]    [Pg.409]    [Pg.67]    [Pg.329]    [Pg.334]    [Pg.83]    [Pg.324]    [Pg.299]    [Pg.302]    [Pg.305]    [Pg.208]    [Pg.722]    [Pg.725]   
See also in sourсe #XX -- [ Pg.2 , Pg.196 ]




SEARCH



Ion-selective electrodes sensor arrays

Selectivity Revisited Sensor Arrays and Pattern Recognition

Sensor array

Sensor selection

Sensor selectivity

Sensors selective

© 2024 chempedia.info