Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Selectivity ionization and

Selective Ionization and Computer Techniques for the Mass Spectrometric Analysis of Air Pollutants... [Pg.195]

These and many other variations (see below) make it possible to find a chromatographic system suitable for application to most complex mixtures. The species to be separated may be large or small, polar or nonpolar, isomeric or homologous, molecular or ionic, volatile or nonvolatile, and, of course, colored and thus visible (as with Tswett s work) or, more commonly, invisible, requiring a sensitive detector based on UV adsorption, selective ionization, and so on. [Pg.225]

Mass spectrometry is a powerful qualitative and quantitative analytical tool that is used to assess the molecular mass and primary amino acid sequence of peptides and proteins. Technical advancements in mass spectrometry have resulted in the development of matrix-assisted laser desorption/ion-ization (MALDI) and electrospray ionization techniques that allow sequencing and mass determination of picomole quantities of proteins with masses greater than 100kDa (see Chapter 7). A time-of flight mass spectrometer is used to detect the small quantities of ions that are produced by MALDI. In this type of spectrometer, ions are accelerated in an electrical field and allowed to drift to a detector. The mass of the ion is calculated from the time it takes to reach the detector. To measure the masses of proteins in a mixture or to produce a peptide map of a proteolytic digest, from 0.5 to 2.0 p.L of sample is dried on the tip of tlie sample probe, which is then introduced into tire spectrometer for analysis. With this technique, proteins located on the surfaces of cells are selectively ionized and analyzed. [Pg.590]

The next stage of experimental control consists in forming the reactants in known electronic, vibrational, and rotational states either by selective ionization and excitation or by state selection. (Here, the neutral reactant must also be formed as a beam or else the state selection will be lost by collision.) Once again, total integral, integral reactive, and integral nonreactive cross sections may be measured, but the particular information... [Pg.107]

Pu (86 years) is formed from Np. Pu is separated by selective oxidation and solvent extraction. The metal is formed by reduction of PuF with calcium there are six crystal forms. Pu is used in nuclear weapons and reactors Pu is used as a nuclear power source (e.g. in space exploration). The ionizing radiation of plutonium can be a health hazard if the material is inhaled. [Pg.318]

Experimental access to the probabilities P(E ,E) for energy transfer in large molecules usually involves teclmiques providing just the first moment of this distribution, i.e. the average energy (AE) transferred in a collision. Such methods include UV absorption, infrared fluorescence and related spectroscopic teclmiques [11. 28. 71. 72, 73 and 74]. More advanced teclmiques, such as kinetically controlled selective ionization (KCSI [74]) have also provided infonnation on higher moments of P(E ,E), such as ((AE) ). [Pg.1055]

Hold U, Lenzer T, Luther K, Reihs K and Symonds A C 2000 Collisional energy transfer probabilities of highly excited molecules from kinetically controlled selective ionization (KCSI). I. The KCSI technique experimental approach for the determination of P(E, E) in the quasicontinuous energy ranged. Chem. Phys. 112 4076-89... [Pg.1086]

Atomic- Vapor Laser Isotope-Separation. Although the technology has been around since the 1970s, laser isotope separation has only recently matured to the point of industrialization. In particular, laser isotope separation for the production of fuel and moderators for nuclear power generation is on the threshold of pilot-plant demonstrations in several countries. In the atomic vapor laser isotope-separation (AVLIS) process, vibrationaHy cooled U metal atoms are selectively ionized by means of a high power (1—2 kW) tunable copper vapor or dye laser operated at high (kHz) repetition rates (51,59,60). [Pg.322]

Fast concentration and sample injection are considered with the use of a theory of vibrational relaxation. A possibility to reduce a detection limit for trinitrotoluene to 10 g/cnf in less than 1 min is shown. Such a detection limit can by obtained using selective ionization combined with ion drift spectrometry. The time of detection in this case is 1- 3 s. A detection technique based on fluorescent reinforcing polymers, when the target molecules strongly quench fluorescence, holds much promise for developing fast detectors. [Pg.165]

The SIMS analytical ion signal of a specific element or isotope also can be enhanced by selective ionization of particular atoms, and the detection limit for that element thereby improved. This mode of SNMS is important to specific applications, but it lacks the generality inherent in nonselective SNMS methods. The focus of this article will be on the methods for obtaining complete, accurate, and matrix-independent compositions of chemically complex thin-film structures and materials. [Pg.573]

In the process of SNMS analysis, sputtered atoms are ionized while passii through the ionizer and are accelerated into the mass spectrometer for mass analysis. The ion currents of the analyzed ions are measured and recorded as a function of mass while stepping the mass spectrometer through the desired mass or element sequence. If the purpose of the analysis is to develop a depth profile to characterize the surface and subsurface regions of the sample, the selected sequence is repeated a number of times to record the variation in ion current of a selected elemental isotope as the sample surfiice is sputtered away. [Pg.575]

The term following EL is always less than unity so that an adventitious correction to the laboratory energy occurs. This enhances the precision of the Er measurement. As with electrons, selection rules for ionization and dissociation seem to be relaxed. [Pg.123]

It is likely that the answers to these questions will come only from more selective and sophisticated experiments than have been done hitherto, although some useful directions have been established. The use of high-sensitivity electron spin resonance for the study in situ of anticipated radical species will likely be possible, if the background signals from other radiation-produced species are not too intense. Studies of the chemistry of implanted atoms and ions in solid organometallic substrates will make it possible to start with totally unbound atoms which suffer no Auger ionization and thus to simulate the extreme of the total recoil. Careful studies of the thermal annealing effects, especially in the presence of reactive atmospheres, will... [Pg.248]

The selective ionization of EEPs is attained due to an ionization potential difference between the excited and ground states of an atom or a molecule, a difference that is equal to the excitation energy. Thus, the ionization potentials of oxygen states and Zj are 1.0 and 1.6 eV,... [Pg.295]

Scheme 10.3 gives some examples of pinacol and related rearrangements. Entry 1 is a rearrangement done under strongly acidic conditions. The selectivity leading to ring expansion results from the preferential ionization of the diphenylcarbinol group. Entry 2, a preparation of 2-indanone, involves selective ionization at the benzylic alcohol, followed by a hydride shift. [Pg.888]

For ionizable sample molecules, it is possible to create an effective sink condition in PAMPA by selecting buffers of different pH in the donor and acceptor compartments. For example, consider salicylic acid (v>Ka 2.88 see Table 3.1). According to the pH partition hypothesis, only the free acid is expected to permeate lipophilic membranes. If the donor pH < 2 and the acceptor pH is 7.4, then as soon as the free acid reaches the acceptor compartment, the molecule ionizes, and the concentration of the free acid becomes effectively zero, even though the total concentration of the species in the acceptor compartment may be relatively high. This situation may be called an ionization-maintained sink. [Pg.138]

In this section, the relationship between the measured quantity and the desired center-of-mass differential cross-section will be established and a brief description of the data analysis procedure will then be given. First, consider a Newton sphere with a single value of the product velocity v (see Fig. 4). From the Doppler-shift formula, at a given laser wavelength, the Doppler effect selectively ionizes those ions with vz = vcosO in the... [Pg.9]


See other pages where Selectivity ionization and is mentioned: [Pg.972]    [Pg.590]    [Pg.52]    [Pg.29]    [Pg.43]    [Pg.42]    [Pg.972]    [Pg.590]    [Pg.52]    [Pg.29]    [Pg.43]    [Pg.42]    [Pg.220]    [Pg.344]    [Pg.872]    [Pg.1424]    [Pg.568]    [Pg.19]    [Pg.403]    [Pg.111]    [Pg.568]    [Pg.139]    [Pg.199]    [Pg.448]    [Pg.19]    [Pg.71]    [Pg.30]    [Pg.712]    [Pg.100]    [Pg.53]    [Pg.315]    [Pg.316]    [Pg.429]    [Pg.138]    [Pg.482]    [Pg.614]    [Pg.649]    [Pg.813]    [Pg.593]    [Pg.202]   
See also in sourсe #XX -- [ Pg.386 ]

See also in sourсe #XX -- [ Pg.338 ]




SEARCH



Ionization selective

© 2024 chempedia.info