Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Scope traces

Fig. 2.11 Scope traces for TM-AFM height and amplitude images recorded for different gain settings (details see text)... Fig. 2.11 Scope traces for TM-AFM height and amplitude images recorded for different gain settings (details see text)...
Fig. 2.48 Scope traces (TM-AFM) with high (upper panel) and too low (middle panel) gains. The mounting angle of the AFM cantilever and the inclination angle of the tip on the cantilever determine the possibility to image steep features, as shown for a silicon nitride CM AFM probe in the bottom panel (reproduced with kind permission from the Veeco user manual). As a result of this, the tip s interaction with sidewalls may depend on the direction... Fig. 2.48 Scope traces (TM-AFM) with high (upper panel) and too low (middle panel) gains. The mounting angle of the AFM cantilever and the inclination angle of the tip on the cantilever determine the possibility to image steep features, as shown for a silicon nitride CM AFM probe in the bottom panel (reproduced with kind permission from the Veeco user manual). As a result of this, the tip s interaction with sidewalls may depend on the direction...
Perhaps the transmitter is not putting out pulses. Can you see pulse feedthrough on the start of the scope trace Can you use the scope to check the output of the transmitter to make sure that it is pulsing (Use an indirect method. See Section VI.A.l.)... [Pg.453]

The first-order diffraction intensity is recorded on a storage oscilloscope. The YAG pulse is 10 ns long, and the detector time constant is 10 ns. This must be kept in mind when interpreting the scope trace. [Pg.207]

Rounding is determined from the 15 kHz signal. It is realistic to delay the start point and to define a duration along the scope trace for the measurement. Separate observations should be made on rising and falling sides of the square wave, as shown in Fig. 20.35. [Pg.2190]

Any time the scope trace disappears, turn the VOLTS / DIV towards the left, to 5 V, and switch the TRIGGER SOURCE to LINE. Adjust POSITION, Y slowly up or down all the way, until the visible line appears again. Then adjust these knobs back toward the desired settings, in small steps. [Pg.123]

Other items related to the site conditions that should be communicated are temperature range, if outdoor and type of protection, if outdoor (Is there a roof Are there sides Is the entire installation completely open ). The requirement for heat tracing and other details of this nature that the vendor is to include in his scope of supply should be specified. Whether the machine is at grade or is elevated must also be specified. [Pg.444]

The procedure is experimentally simple, and the workup involves only the destruction of the traces of hydrogen peroxide with manganese dioxide and evaporation of the hexamethyldisiloxane. Pyridine additives serve to buffer the highly acidic rhenium species and to shut down the detrimental acid-catalyzed epoxideopening pathways. The scope of this transformation is best appreciated through the examples presented in Table 12.2 [28],... [Pg.451]

Adsorptive stripping analysis greatly enhances the scope of stripping measurements toward numerous trace elements (23,24). This relatively new strategy involves the... [Pg.80]

The goals of this chapter do not include a "state of the art" literature review which would be appropriate for a more in-depth discussion of one particular problem area. Rather the intent is to illustrate mechanistic approaches to river quality assessment using the three globally relevant water quality problem areas discussed in the previous chapter dissolved oxygen depletion, erosion/deposition, and potentially toxic trace elements. The information provided does not include all rationale, methology or approaches used in the study as this is beyond the scope of the chapter. Additional general information on application of the intensive river quality assessment approach in the Willamette River basin may be found elsewhere (4-9, 11-14, 17). [Pg.261]

Packed column SFC and CE are both able to make inroads into the application area served by HPLC, but from opposite extremes of polarity and with little overlap. CE is likely to be more efficient and faster, but mostly applicable to very polar molecules and ions. SFC qualifies as a more reproducible, trace technique, with greater selectivity and multiple detection options. HPLC and CE have been compared [365], Owing to their orthogonality, CZE and SFC are worth developing, not in competition or as an alternative to HPLC, but as an additional method in order to augment the information obtained from the analysis. With the broad scope of possible eluents and stationary phases, HPLC has fewer constraints than SFC and CZE. The parameters influencing selectivity may be used as a guide to optimisation (Table 4.44). [Pg.245]

A loop exists where a close path can be traced through the network. There is a loop in the network shown in Figure 3.27. The loop is shown in Figure 3.28. The presence of a loop indicates that there is scope for reducing the number of exchangers. [Pg.122]

The analysis methods are national in scope and address emissions from a wide variety of industrial and community source types. The materials reviewed are of widely disparate natures. They include metals, and bulk and trace hydrocarbons, including chlorinated and oxide derivatives of hydrocarbons. The analyses are intended to be preliminary screening analyses for use in scoping and prioritizing regulatory attention to toxic exposures from the chemicals studied. [Pg.67]

C—H bond 174-280,28i por comparison, only trace amounts of cyclopentane resulted from the CuS04-catalyzed decomposition of 1 -diazo-2-octanone or l-diazo-4,4-dimethyl-2-pentanone 277). It is obvious that the use of Rh2(OAc)4 considerably extends the scope of transition-metal catalyzed intramolecular C/H insertion, as it allows for the first time, efficient cyelization of ketocarbenoids derived from freely rotating, acyclic diazoketones. This cyelization reaction can also be highly diastereo-selective, as the exclusive formation of a m is-2,3-disubstituted cyclopentane carboxylate from 307 shows281 a). The stereoselection has been rationalized by... [Pg.195]

The traces of fat in wholemeal flour reduce the shelf life of the flour as they become rancid fairly rapidly. Claims are made that this trace of fat has important dietary properties but the veracity or otherwise of this claim is beyond the scope of this book. [Pg.84]

Anderlini, V.C. 1992. The effect of sewage on trace metal concentrations and scope for growth in Mytilus edulis aoteanus and Perna canaliculus from Wellington Harbour, New Zealand. Sci. Total Environ. 125 263-288. [Pg.574]


See other pages where Scope traces is mentioned: [Pg.64]    [Pg.486]    [Pg.35]    [Pg.36]    [Pg.36]    [Pg.36]    [Pg.71]    [Pg.72]    [Pg.378]    [Pg.404]    [Pg.64]    [Pg.486]    [Pg.35]    [Pg.36]    [Pg.36]    [Pg.36]    [Pg.71]    [Pg.72]    [Pg.378]    [Pg.404]    [Pg.114]    [Pg.212]    [Pg.2029]    [Pg.261]    [Pg.84]    [Pg.452]    [Pg.211]    [Pg.856]    [Pg.508]    [Pg.363]    [Pg.61]    [Pg.61]    [Pg.382]    [Pg.406]    [Pg.178]    [Pg.11]    [Pg.70]    [Pg.162]    [Pg.169]    [Pg.205]    [Pg.611]    [Pg.500]    [Pg.139]   
See also in sourсe #XX -- [ Pg.35 , Pg.71 ]




SEARCH



© 2024 chempedia.info