Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

SAR

Without going into details of the chromatographic method, a SAR separation (asphaltenes having been eliminated) can be performed in a mixed column of silica followed by alumina. The saturated hydrocarbons are eluted by heptane, the aromatics by a 2 1 volume mixture of heptane and toluene, and the resins by a 1 1 1 mixture of dichloromethane, toluene and methanol. [Pg.83]

TOF-SARS (time-of-flight scattering and recoiling spectrometry) no 13 1.2... [Pg.1754]

A) TIME OF FLIGHT SCATTERING AND RECOILING SPECTROMETRY (TOF-SARS)—SHADOW CONE BASED EXPERIMENT... [Pg.1805]

In TOF-SARS [9], a low-keV, monoenergetic, mass-selected, pulsed noble gas ion beam is focused onto a sample surface. The velocity distributions of scattered and recoiled particles are measured by standard TOF methods. A chaimel electron multiplier is used to detect fast (>800 eV) neutrals and ions. This type of detector has a small acceptance solid angle. A fixed angle is used between the pulsed ion beam and detector directions with respect to the sample as shown in figure Bl.23.4. The sample has to be rotated to measure ion scattering... [Pg.1805]

Figure Bl.23.4. Schematic diagram of TOE scattermg and recoiling spectrometry (TOF-SARS) illustrating the plane of scattering fonned by the ion beam, sample and detector. TOE spectra (a) are collected with fixed... Figure Bl.23.4. Schematic diagram of TOE scattermg and recoiling spectrometry (TOF-SARS) illustrating the plane of scattering fonned by the ion beam, sample and detector. TOE spectra (a) are collected with fixed...
Figure Bl.23.5. Schematic illustration of tlie TOE-SARS spectrometer system. A = ion gun, B = Wien filter, C = Einzel lens, D = pulsing plates, E = pulsing aperture, E = deflector plates, G = sample, PI = electron multiplier detector with energy prefilter grid and I = electrostatic deflector. Figure Bl.23.5. Schematic illustration of tlie TOE-SARS spectrometer system. A = ion gun, B = Wien filter, C = Einzel lens, D = pulsing plates, E = pulsing aperture, E = deflector plates, G = sample, PI = electron multiplier detector with energy prefilter grid and I = electrostatic deflector.
The most connnon detectors used for TOF-SARS are continuous dynode channel electron multipliers which... [Pg.1808]

A systematic comparison of two sets of data requires a numerical evaluation of their likeliness. TOF-SARS and SARIS produce one- and two-dhnensional data plots, respectively. Comparison of sunulated and experimental data is accomplished by calculating a one- or two-dimensional reliability (R) factor [33], respectively, based on the R-factors developed for FEED [34]. The R-factor between tire experimental and simulated data is minimized by means of a multiparameter simplex method [33]. [Pg.1812]

TOF-SARS and SARIS are capable of detecting all elements by either scattering, recoiling or both teclmiques. TOF peak identification is straightforward by converting equation (Bl.23.lt and equation (B 1.23.81 to the flight times of the scattered and recoiled particles as... [Pg.1812]

The major role of TOF-SARS and SARIS is as surface structure analysis teclmiques which are capable of probing the positions of all elements with an accuracy of <0.1 A. They are sensitive to short-range order, i.e. individual interatomic spacings that are <10 A. They provide a direct measure of the interatomic distances in the first and subsurface layers and a measure of surface periodicity in real space. One of its most important applications is the direct determination of hydrogen adsorption sites by recoiling spectrometry [12, 4T ]. Most other surface structure teclmiques do not detect hydrogen, with the possible exception of He atom scattering and vibrational spectroscopy. [Pg.1823]

Grizzi O, Shi M, Bu H, and Rabalais J W 1990 Time-of-flight scattering and recoiling spectrometer (TOF-SARS) for surface analysis Rev. Sc/. Instrum. 61 740-52... [Pg.1825]

Masson F and Rabalais J W 1991 Time-of-flight scattering and recoiling spectrometry (TOF-SARS) analysis of Pt 110. I. Quantitative structure study of the clean (1 x 2) surface Surf. Sc/. 253 245-57... [Pg.1826]

The Fresnel equations predict that reflexion changes the polarization of light, measurement of which fonns the basis of ellipsometry [128]. Although more sensitive than SAR, it is not possible to solve the equations linking the measured parameters with n and d. in closed fonn, and hence they cannot be solved unambiguously, although their product yielding v (equation C2.14.48) appears to be robust. [Pg.2838]

This is the domain of establishing Structure-Property or Structure-Activity Relationships (SPR or SAR), or even of finding such relationships in a quantitative manner (QSPR or QSAR). [Pg.3]

The fundamental assumption of SAR and QSAR (Structure-Activity Relationships and Quantitative Structure-Activity Relationships) is that the activity of a compound is related to its structural and/or physicochemical properties. In a classic article Corwin Hansch formulated Eq. (15) as a linear frcc-cncrgy related model for the biological activity (e.g.. toxicity) of a group of congeneric chemicals [37, in which the inverse of C, the concentration effect of the toxicant, is related to a hy-drophobidty term, FI, an electronic term, a (the Hammett substituent constant). Stcric terms can be added to this equation (typically Taft s steric parameter, E,). [Pg.505]

B and W J Howe 1991. Computer Design of Bioactive Molecules - A Method for Receptor-Based Novo Ligand Design. Proteins Structure, Function and Genetics 11 314-328. i H L 1965. The Generation of a Unique Machine Description for Chemical Structures - A hnique Developed at Chemical Abstracts Service. Journal of Chemical Documentation 5 107-113. J 1995. Computer-aided Estimation of Symthetic Accessibility. PhD thesis. University of Leeds, itan R, N Bauman, J S Dixon and R Venkataraghavan 1987. Topological Torsion A New )lecular Descriptor for SAR Applications. Comparison with Other Descriptors. Journal of emical Information and Computer Science 27 82-85. [Pg.740]

Shuker S B, P J Hadjuk, R P Meadows and R P Fesik 1996. Discovering High-affinity Ligands fc Proteins SAR by NMR. Science 274 1531-1534. [Pg.741]

ISIS Draw, SAR, Excel Desktop modeling and data management Molecular Design Limited, Inc. [Pg.169]

M. G. J. Beets, SAR Structure—Activity Relationships in Human Chemoreception, AppHed Science Pubhshers, London, 1978. [Pg.6]

The dB/d/is limited to 6 T/s out of concern that larger values could cause nerve stimulation. The r-f exposure is limited to a specific absorption rate (SAR) of 0.4 W/kg for the whole body, 0.32 W/kg averaged over the head, and less than 8.0 W/kg spatial peakia any one gram of tissue. These numbers are designed to limit the temperature rise to less than 1°C and localized temperature of no greater than 38°C head, 39°C tmnk, and 40°C ia the extremities. [Pg.56]


See other pages where SAR is mentioned: [Pg.70]    [Pg.1800]    [Pg.1800]    [Pg.1803]    [Pg.1812]    [Pg.1813]    [Pg.1813]    [Pg.1822]    [Pg.1823]    [Pg.1824]    [Pg.1826]    [Pg.2838]    [Pg.3]    [Pg.437]    [Pg.514]    [Pg.594]    [Pg.705]    [Pg.726]    [Pg.326]    [Pg.781]    [Pg.109]    [Pg.166]    [Pg.171]    [Pg.219]    [Pg.219]    [Pg.73]    [Pg.306]    [Pg.576]    [Pg.576]   
See also in sourсe #XX -- [ Pg.24 , Pg.252 , Pg.298 ]

See also in sourсe #XX -- [ Pg.23 ]

See also in sourсe #XX -- [ Pg.103 , Pg.125 ]

See also in sourсe #XX -- [ Pg.42 ]

See also in sourсe #XX -- [ Pg.22 , Pg.23 ]

See also in sourсe #XX -- [ Pg.153 ]

See also in sourсe #XX -- [ Pg.301 ]




SEARCH



SARS

© 2024 chempedia.info