Sample positioning

To describe the X-ray imaging system the projection of 3D object points onto the 2D image plane, and nonlinear distortions inherent in the image detector system have to, be modelled. A parametric camera model based on a simple pinhole model to describe the projection in combination with a polynomal model of the nonlinear distortions is used to describe the X-ray imaging system. The parameters of the model are estimated using a two step approach. First the distortion parameters for fixed source and detector positions are calculated without any knowledge of the projection parameters. In a second step, the projection parameters are calculated for each image taken with the same source and detector positions but with different sample positions. [Pg.485]

Figure Bl.19.34. Cantilever deflection and corresponding frictional force in the v-direction as a fiinction of sample position as a mica sample is scaimed back and forth under a tungsten tip. (Taken from [124], figure 2.)... Figure Bl.19.34. Cantilever deflection and corresponding frictional force in the v-direction as a fiinction of sample position as a mica sample is scaimed back and forth under a tungsten tip. (Taken from [124], figure 2.)...
A typical loop injector showing the sampling position with pressurized solvent flowing through one loop onto the column and the sample solution placed in the other loop at atmospheric pressure. Rotation of the loop carrier through 180° puts the sample into the liquid flow at high pressure with only momentary change in pressure in the system. [Pg.251]

Fig. 4. Schematic of the Closed Container Sampling technique used in the Baxter PARAMAX analy2er showing (a) the collection tube with bar-coded label being brought into sampling position under the caimula (b) the tube raised so that the caimula has penetrated the stopper (c) the sample sensing probe coming through the caimula to aspirate the exact volume required for each assay and (d) after sampling, where the tube is lowered away from the cannula. Fig. 4. Schematic of the Closed Container Sampling technique used in the Baxter PARAMAX analy2er showing (a) the collection tube with bar-coded label being brought into sampling position under the caimula (b) the tube raised so that the caimula has penetrated the stopper (c) the sample sensing probe coming through the caimula to aspirate the exact volume required for each assay and (d) after sampling, where the tube is lowered away from the cannula.
If the tracer concentration is X measured at each sampling position that has its position at y, on a scale along the arc (either in degrees or in meters), estimates of the mean posiHon of the plume at ground level and the variance of the groundlevel concentration distribution are given by ... [Pg.313]

In TEM, a focused electron beam is incident on a thin (less than 200 nm) sample. The signal in TEM is obtained from both undeflected and deflected electrons that penetrate the sample thickness. A series of magnetic lenses at and below the sample position are responsible for delivering the signal to a detector, usually a fluorescent screen, a film plate, or a video camera. Accompanying this signal transmission is a... [Pg.99]

Fig. 1. Schematic diagram illustrating the mechanical instability for (a) a weak spring (spring constant k) a distance D from the surface, experiencing an arbitrary surface force (after [19]) and (b) the experimentally observed force-distance curve relative to the AFM sample position (piezo displacement) for the same interaction. Fig. 1. Schematic diagram illustrating the mechanical instability for (a) a weak spring (spring constant k) a distance D from the surface, experiencing an arbitrary surface force (after [19]) and (b) the experimentally observed force-distance curve relative to the AFM sample position (piezo displacement) for the same interaction.
Depth-sensing nanoindentation is one of the primary tools for nanomechanical mechanical properties measurements. Major advantages to this technique over AFM include (1) simultaneous measurement of force and displacement (2) perpendicular tip-sample approach and (3) well-modeled mechanics for dynamic measurements. Also, the ability to quantitatively infer contact area during force-displacement measurements provides a very useful approach to explore adhesion mechanics and models. Disadvantages relative to AFM include lower force resolution, as well as far lower spatial resolution, both from the larger tip radii employed and a lack of sample positioning and imaging capabilities provided by piezoelectric scanners. [Pg.212]

The setup in Figure 1-7 becomes an effective generator of nearly monochromatic x-rays when various elements inserted in the sample position are irradiated by x-rays of energy sufficient to excite the characteristic spectra that is, when by x-ray excitation the characteristic... [Pg.16]

However, some of the conditions in the alpha ion source do differ significantly from those in conventional ion-molecule sources. The most important difference is caused by the absence of an electric field and the mode of sampling. Positive and negative particles are carried out by mass flow. Therefore it is necessary to understand the reaction and sampling conditions at least qualitatively. For this reason we are devoting this section to a description of the conditions and a discussion of some experiments which were done specifically to obtain a better understanding of the sample prehistory. [Pg.218]

It should be stressed that only those surfaces that actually come in contact with the sample need to be bio-compatible and the major parts of the valve can still be manufactured from stainless steel. The actual structure of the valve varies a little from one manufacturer to another but all are modifications of the basic sample valve shown in figure 13. The valve usually consists of five parts. Firstly there is the control knob or handle that allows the valve selector to be rotated and thus determines the load and sample positions. Secondly, a connecting device that communicates the rotary movement to the rotor. Thirdly the valve body that contains the different ports necessary to provide connections to the mobile phase supply, the column, the sample loop if one is available, the sample injection port and finally a port to waste. Then there is the rotor that actually selects the mode of operation of the valve and contains slots that can connect the alternate ports in the valve body to provide loading and sampling functions. Finally there is a pre-load assembly that furnishes an adequate pressure between the faces of the rotor and the valve body to ensure a leak tight seal. [Pg.140]

Table V shows the concentrations of polymer (usually in THF/polymer/monomer mixtures), the GPC that they were directly injected into, and the Column Code involved (Ref. Table 1). No effect of different concentration was observed in the chromatograms from GPC 2 when concentrations of samples A to E inclusive were changed by 33%. GPC 1 chromatograms were too disturbed by sampling to be useful except as a rough guide to sampling position. Table V shows the concentrations of polymer (usually in THF/polymer/monomer mixtures), the GPC that they were directly injected into, and the Column Code involved (Ref. Table 1). No effect of different concentration was observed in the chromatograms from GPC 2 when concentrations of samples A to E inclusive were changed by 33%. GPC 1 chromatograms were too disturbed by sampling to be useful except as a rough guide to sampling position.
Figure 9.2 illustrates a typical example of normalized transmittance, T(z), of CdTe QDs against the sample position z from the focusing point vdth and vithout aperture [17]. Since the peak ofthe normalized transmittance for the closed aperture precedes the valley, the sign ofthe nonlinear refractive index of CdTe QDs is negative. [Pg.157]

Several remedies have been suggested for improving the PB based pKa prediction methods. Most of them are based on strategies that combine conformational flexibility with the PB calculation. You and Bashford included multiple conformers by systematically scanning the side chain torsion angles [107], Alexov and Gunner used Monte-Carlo protocol to sample positions of hydroxyl and other polar protons [1], This method, referred to as the multi-conformation continuum electrostatic (MCCE), was later extended to include rotamers for residues that have strong electrostatic... [Pg.266]


See other pages where Sample positioning is mentioned: [Pg.488]    [Pg.1692]    [Pg.548]    [Pg.298]    [Pg.298]    [Pg.305]    [Pg.185]    [Pg.281]    [Pg.196]    [Pg.136]    [Pg.351]    [Pg.865]    [Pg.543]    [Pg.9]    [Pg.235]    [Pg.241]    [Pg.362]    [Pg.571]    [Pg.141]    [Pg.142]    [Pg.833]    [Pg.842]    [Pg.150]    [Pg.383]    [Pg.18]    [Pg.46]    [Pg.79]    [Pg.310]    [Pg.573]    [Pg.531]    [Pg.31]    [Pg.211]    [Pg.527]    [Pg.275]   
See also in sourсe #XX -- [ Pg.65 ]