The major adverse effect associated with the use of viscoelastic substances, such as hyaluronate sodium, is a transient rise in intraocular pressure in the immediate postoperative period, attributed to its viscoelastic nature, resulting in coating and plugging of the trabecular mesh-work. For this reason, it is advisable to dilute hyaluronate sodium at the end of the surgical procedure with a balanced salt solution. Chondroitin sulfate is relatively less likely to precipitate such extreme rises in intraocular pressure because it is cleared rapidly from the trabecular meshwork. However, with any technique or chemical used in surgery there is always the potential for an unexpected adverse effect, and the risks of Viscoat include subepithelial calcium deposition and keratopathy (3). [Pg.1699]

The study of acid-base interaction is an important branch of interfacial science. These interactions are widely exploited in several practical applications such as adhesion and adsorption processes. Most of the current studies in this area are based on calorimetric studies or wetting measurements or peel test measurements. While these studies have been instrumental in the understanding of these interfacial interactions, to a certain extent the interpretation of the results of these studies has been largely empirical. The recent advances in the theory and experiments of contact mechanics could be potentially employed to better understand and measure the molecular level acid-base interactions. One of the following two experimental procedures could be utilized (1) Polymers with different levels of acidic and basic chemical constitution can be coated on to elastomeric caps, as described in Section 4.2.1, and the adhesion between these layers can be measured using the JKR technique and Eqs. 11 or 30 as appropriate. For example, poly(p-amino styrene) and poly(p-hydroxy carbonyl styrene) can be coated on to PDMS-ox, and be used as acidic and basic surfaces, respectively, to study the acid-base interactions. (2) Another approach is to graft acidic or basic macromers onto a weakly crosslinked polyisoprene or polybutadiene elastomeric networks, and use these elastomeric networks in the JKR studies as described in Section 4.2.1. [Pg.134]

Another potential material for cell construction purposes is nickel. For instance, Eka Chemicals has employed nickel cartridges with standard GORE-TEX membranes to remove graphite particles directly from a caustic decomposer. The result was promising. Not only was the graphite removed but the quantities of mercury were reduced to levels of <10 pg. Aside from the cleaner caustic, the volume of sludge was drastically reduced since no pre-coat was required in this procedure. [Pg.307]

Safety requires you to think in advance about what you will do never do anything that seems dangerous. Know how to use safety equipment such as goggles, fume hood, lab coat, gloves, emergency shower, eyewash, and fire extinguisher. Chemicals should be stored and used in a manner that minimizes contact of solids, liquids, and vapors with people. Environmentally acceptable disposal procedures should be established in advance for every chemical that you use. Your lab notebook tells what you did and what you observed it should be understandable to other people. It also should allow you to repeat an experiment in the same manner in the future. You should understand the principles of operation of electronic and mechanical balances and treat them as delicate equipment. Buoyancy corrections are required in accurate work. Burets should be read in a reproducible manner and drained slowly for best results. Always interpolate between markings to obtain accuracy one deci-... [Pg.37]

Ceramic and semiconductor thin films have been prepared by a number of methods including chemical vapor deposition (CVD), spray-coating, and sol-gel techniques. In the present work, the sol-gel method was chosen to prepare uniform, thin films of titanium oxides on palladium Titanium oxide was chosen because of its versatility as a support material and also because the sol-gel synthesis of titania films has been clearly described by Takahashi and co-workers (22). The procedure utilized herein follows the work of Takahashi, but is modified to take advantage of the hydrogen permeability of the palladium substrate. Our objective was to develop a reliable procedure for the fabrication of thin titania films on palladium, and then to evaluate the performance of the resulting metalloceramic membranes for hydrogen transport and ethylene hydrogenation for comparison to the pure palladium membrane results. [Pg.174]


See other pages where Results chemical coating procedure is mentioned: [Pg.124]    [Pg.248]    [Pg.298]    [Pg.8]    [Pg.473]    [Pg.134]    [Pg.191]    [Pg.372]    [Pg.13]    [Pg.471]    [Pg.472]    [Pg.473]    [Pg.475]    [Pg.84]    [Pg.133]    [Pg.664]    [Pg.445]    [Pg.22]    [Pg.45]    [Pg.517]    [Pg.702]    [Pg.271]    [Pg.34]    [Pg.302]    [Pg.5]    [Pg.188]    [Pg.57]    [Pg.230]    [Pg.101]    [Pg.15]    [Pg.590]    [Pg.22]    [Pg.45]    [Pg.117]    [Pg.562]    [Pg.342]    [Pg.692]    [Pg.340]    [Pg.358]    [Pg.218]    [Pg.11]    [Pg.102]    [Pg.311]    [Pg.366]    [Pg.641]    [Pg.261]   