Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Resolution discussion

Since the RIG detector measures the bulk property of the concentration gradient directly, the response at any time point is a fiinction of the difiusion coefficient of the individual analyte present, and the overall response should be ven by the weighted sum of the responses of the individual components present as given by equation 11. Because of the presence of time-based resolution discussed previously, there should be a time-based selectivity comparable to the wavelength selectivity in an absorbance detection, which enables one to resolve the component peaks in a mixture. If there is no time-based selectivity, the response of one PEG almost be a scalar multiple of the response of... [Pg.39]

The mechanism shown uses m-chloroperoxybenzoic acid (mCPBA) as the oxidant. The enzymatically catalyzed reaction uses molecular oxygen. The reaction is considered a kinetic resolution, discussed further in Section 3.4. The enzyme reacts faster with the S enantiomer, allowing formation of the S lactone and separation of the unreacted R ketone, which can be converted to the R lactone using traditional Baeyer-Villiger conditions [36]. [Pg.107]

For the Brownian motion imbedded ELS spectrum. Ware and Flygare [26] defined the analytical resolution (not the spectral resolution discussed earlier) in terms of the ratio of the Doppler shift to the diffusion broadened half-width ... [Pg.332]

To derive a reservoir geological model various methods and techniques are employed mainly the analysis of core material, wireline logs, high resolution seismic and outcrop studies. These data gathering techniques are further discussed in Sections 5.3 and 2.2. [Pg.80]

The paper presents the results from systematic comparisons of contrast and resolution obtained with different types of radiation sources on steel thicknesses from 5 to 40 mm. These results have been taken into account with the definitions of the European standard for radiographic inspection of weldments (EN 1435) that is approved since 1997. Conclusions from practical investigations on pipe line sites, in petrochcemical plants and in nuclear power stations will be discussed as well. Furthermore, the presentation will stipulate a variety of advantages obtained from the new source in terras of coUimation and radiation protection. [Pg.423]

The first step involved massive testing at ANDREX laboratory to determine the optimal detection process. Two imaging methods were discussed, one using a linear detector array, the other using a high resolution image intensifier. [Pg.587]

The ability to control the position of a fine tip in order to scan surfaces with subatomic resolution has brought scanning probe microscopies to the forefront in surface imaging techniques. We discuss the two primary techniques, scanning tunneling microscopy (STM) and atomic force microscopy (AFM) the interested reader is referred to comprehensive reviews [9, 17, 18]. [Pg.294]

These days, remarkably high-resolution spectra are obtained for positive and negative ions using coaxial-beam spectrometers and various microwave and IR absorption teclmiques as described earlier. Infonnation on molecular bond strengths, isomeric fonus and energetics may also be obtained from the teclmiques discussed earlier. The kinetics of cluster-ion fonuation, as studied in a selected-ion flow tube (SIFT) or by high-pressure... [Pg.813]

If the experunental technique has sufficient resolution, and if the molecule is fairly light, the vibronic bands discussed above will be found to have a fine structure due to transitions among rotational levels in the two states. Even when the individual rotational lines caimot be resolved, the overall shape of the vibronic band will be related to the rotational structure and its analysis may help in identifying the vibronic symmetry. The analysis of the band appearance depends on calculation of the rotational energy levels and on the selection rules and relative intensity of different rotational transitions. These both come from the fonn of the rotational wavefunctions and are treated by angnlar momentum theory. It is not possible to do more than mention a simple example here. [Pg.1139]

The extension of the voxel in a radial direction gives infomiation on the lateral resolution. Since the lateral resolution has so far not been discussed in temis of the point spread function for the conventional microscope, it will be dealt with here for both conventional and confocal arrangements [13]. The radial intensity distribution in the focal plane (perpendicular to the optical axis) in the case of a conventional microscope is given by... [Pg.1670]

The discussion of Rutherford backscattering spectrometry starts with an overview of the experimental target chamber, proceeds to the particle kinematics that detennine mass identification and depth resolution, and then provides an example of the analysis of a silicide. [Pg.1829]

He Y, Pochert J, Quack M, Ranz R and Seyfang G 1995 Dynamics of unimolecular reactions induced by monochromatic infrared radiation experiment and theory for C F XI—> C F X + I probed with hyperfine-, Doppler- and uncertainty limited time resolution of iodine atom infrared absorption J. Chem. Soc. Faraday Discuss. 102 275-300... [Pg.2151]

Using the data from Problem 1, calculate the resolution and selectivity factors for each pair of adjacent compounds. For resolution, use both equations 12.1 and 12.21, and compare your results. Discuss how you might improve the resolution between compounds B and C. The retention time for an unretained solute is 1.19 min. [Pg.615]

Quadmpole mass spectrometers (mass filters) allow ions at each m/z value to pass through the analyzer sequentially. For example, ions at m/z 100, 101, and 102 are allowed to pass one after the other through the quadmpole assembly so that first m/z 100 is transmitted, then m/z 101, then m/z 102, and so on. Therefore, the ion collector at the end of the quadmpole unit needs to cover only one point or focus in space and can be placed immediately behind the analyzer (Figure 30.1). A complete mass spectram is recorded over a period of time (temporally), which is set by the voltages on the quadmpole analyzer. In this mode of operation, the ions are said to be scanned sequentially. The resolution of m/z values is dependent solely on the analyzer and not on the detector. The single-point collector is discussed in detail in Chapter 28. [Pg.211]

The array system is discussed in Chapter 29. With array detection, resolution of m/z values depends both on the analyzer and the collector. Historically, the method for recording ions dispersed in space was to use a photographic plate, which was placed in the focal plane such that all ions struck the photographic plate simultaneously but at different positions along the plate, depending on m/z value. This method of detection is now rarely used because of the inconvenience of having to develop a photographic plate. [Pg.212]

Commercial mass analyzers are based almost entirely on quadrupoles, magnetic sectors (with or without an added electric sector for high-resolution work), and time-of-flight (TOE) configurations or a combination of these. There are also ion traps and ion cyclotron resonance instruments. These are discussed as single use and combined (hybrid) use. [Pg.280]

The choice of phase of the sample is important. Generally, in high-resolution spectroscopy (see Section 3.3.1 for a discussion of resolution), the sample is in the gas phase at a pressure which is sufficiently low to avoid pressure broadening (see Section 2.3.3). In the liquid... [Pg.42]


See other pages where Resolution discussion is mentioned: [Pg.202]    [Pg.45]    [Pg.115]    [Pg.229]    [Pg.65]    [Pg.45]    [Pg.279]    [Pg.191]    [Pg.202]    [Pg.45]    [Pg.115]    [Pg.229]    [Pg.65]    [Pg.45]    [Pg.279]    [Pg.191]    [Pg.472]    [Pg.8]    [Pg.28]    [Pg.307]    [Pg.1122]    [Pg.1283]    [Pg.1328]    [Pg.1421]    [Pg.1424]    [Pg.1509]    [Pg.1623]    [Pg.1625]    [Pg.1625]    [Pg.1643]    [Pg.1656]    [Pg.1656]    [Pg.1658]    [Pg.1673]    [Pg.1716]    [Pg.1786]    [Pg.1968]    [Pg.1977]    [Pg.2487]    [Pg.678]    [Pg.213]    [Pg.378]   
See also in sourсe #XX -- [ Pg.27 , Pg.28 , Pg.29 , Pg.30 , Pg.31 , Pg.32 , Pg.33 , Pg.34 , Pg.203 , Pg.204 , Pg.205 , Pg.206 ]




SEARCH



High-resolution electron microscopy general discussion

© 2024 chempedia.info